Heat pump water heater

Advertisement

3、 Remove the Air channel and fan
4、 Remove the Magnesium rod
Off the power and close the inlet valve, open any outlet valve, exhaust pressure, when no water
flows out of time,turn off all the valves.
① Remove the magnesium rod cover;
② After remove the magnesium rod, according to the consumption of magnesium rod, determine
whether you need to replace.
magnesium rod cover
5、 Remove the temperature sensor
① Remove the fixing screws, remove the water tank flange cover;
② Remove the temperature sensors and thermostat temperature sensor.
water tank flange cover
1. remove the
Air channel - up
Temperature tube(up)
Temperature tube(down)
34
2. remove the
fan
3. remove the Air
channel – down
magnesium rod
First
insert
the
temperature
sensor, and then insert the
thermostat temperature sensor to
Temperature tube ( down ) .
Temperature sensor must be
inserted into the bottom of the
tube.