Download Print this page

Lakeshore DRC-93C User Manual page 75

Temperature controller

Advertisement

Model
DRC-93c
Section IV
05,31,20BO,RESVRD,
The information lines for Sensor
02,02,02,02,02,02,02,02,
Curves
05
through
31
will only be
02,02,02,02,02,02,02,02,
present
if
these
curves
are
02,02,02,02,02,02,02,02,
actually present either as user
02,02,02,02,02,02,02,02,
generated curves or as Precision
02,02,02,02,02,02,02,02,
option curves.
The Information
02,02,02,02,02,02,02,02,
Table is output as one
very
lonq
02,02,02,02,02,02,02,02,
character
string.
02,02,02,02,02,02,02,02
The following program is for the
4 . 1 6 . 2
The
XIN1N2
Command
HP86B and is an example of the
XDT
output (SCIT) for a unit with only
The XDN1N2 command is used to
Standard Curves
00
thru
05
present.
output a particular Sensor Curve
(rather than all the curves stored
1 0
REM Program to Output SCIT
within the instrument as in the
XDA
20
DIM FILETABLE$[321]
command) with N1N2 being the curve
30 OUTPUT
712;"XDT"
!Ask for
number
00
thru
31.
The format of
40
ENTER 712;FILETABLE$ !Input SCIT
the Sensor Curve output is given in
50
DISP FILETABLE$[1,16]!Bytes Free
Table 4-18.
The information is
70
DISP FILETABLE$[39,56] !Curve
00
string.
The following program is
80
DISP FILETABLE$[57,74] !Curve
01
for the HP86B and is an example of
90
DISP FILETABLE$[75,92] !Curve
02
the XDN1N2 to output Sensor Curve
100
DISP FILETABLE$
[
93,1101
!
Curve
0 0 .
03
110
DISP
FILETABLE$[111,128]!Curve
10
REM Program to output Curve
04
Table
110
DISP FILETABLE$[129,152] !A00
20
DIM Curve$[462]
120
DISP FILETABLE$
[
153,1761
130
DISP FILETABLE?,$[177,200]
140
DISP
FILETABLE$[201,224]
50 REM Display Curve #,
Title,
!Thru A1F
Temperature
150 DISP FILETABLE$[225,248] !BOO
60
REM Coefficient and Number of
160
DISP FILETABLE$[249,272]
Breakpoints
70
DISP Curve$[1,27]
170
DISP FILETABLE$[273,296]
80 REM
Display voltage and temp
180
DISP
FILETABLE$[297,319]
data points
!thru B1F
90
I=28
190
END
100
DISP Curve$[I,I+41]
!
Voltage;
Note that the last character to be
110
IF I=447 THEN
140 ! I=477
for
displayed is number
319
since the
D.Pnt
31
Terminators
(CR)
(LF) have to be
120 I=I+42
input but not displayed.
This
130
GOTO 100
program results in the following
140
DISP Curve$ [448,460]
output
of
the
Sensor
Curve
150
END
Information Table.
3584 BYTES FREE,
0200
IS
NEXT
LOCATION,
00,31,1D40,DRC-D
,
01,3 1,
lDFO, DRC-E1
,
02,31,1EAO,CRV
10,
03,31,1F50,DIN-PT,
04,31,2000,cRV
10,
60
DISP FILETABLE$[17,38] !Next Loc
output as one very
long
character
30
OUTPUT
720;"XD00"
40
ENTER 720;Curves
Temp.
COPYRIGHT
3/88
LSCI