Beretta IDRA MS 150 Installation And Operation Manual

Storage cylinder

Advertisement

Quick Links

Installation and Operation Manual
IDRA MS
Storage cylinder
EN
Installation and Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Beretta IDRA MS 150

  • Page 1 Installation and Operation Manual IDRA MS Storage cylinder Installation and Operation Manual...
  • Page 2: Table Of Contents

    RANGE The following symbols are used in this manual: MODEL CODE Identifies actions that require caution CAUTION! = IDRA MS 150 20128979 and adequate preparation. Identifies actions that you MUST NOT do. ACCESSORIES STOP! = For a complete list of accessories and details of their com- patibility, refer to the Catalogue.
  • Page 3: Precautions

    This lists the technical specifications and performance Never attempt to install the system without using suit- of the product. able personal protection equipment and without fol- lowing all applicable occupational safety standards. Beretta Caldaie Via Risorgimento, 13 23900 Lecco (LC) BOLLITORE T067774IFE...
  • Page 4: Technical Specifications

    GENERAL INFORMATION TECHNICAL SPECIFICATIONS IDRA MS DESCRIPTION Type of storage cylinder Vertical, glazed Heat exchanger layout Vertical, with elliptical section Storage cylinder capacity Diameter of storage cylinder with insulation Diameter of storage cylinder without insulation Height with insulation 1088 Height without insulation Insulation thickness Total net weight Quantity/diameter/length of magnesium anode...
  • Page 5 GENERAL INFORMATION IDRA MS EMPTYING IN 10’ Quantity of domestic water obtained in 10’ with boiler pre-heated to 60°C (coil probe point reference) and pri- mary exchanger at the indicated delivery temperature, considering an increase of the domestic water tempera- ture of 30°C between inlet and outlet (according to EN 12897).
  • Page 6: Installation

    INSTALLATION UNPACKING THE PRODUCT PLACE OF INSTALLATION Heaters are supplied in a single package storage cylinders can be installed in any IDRA MS IDRA MS on a wooden pallet. room where there is no specific requirement for an electri- The following items are delivered in a plastic bag inside the cal protection rating higher than IP X0D.
  • Page 7: Water Connections

    INSTALLATION 11 WATER CONNECTIONS IDRA MS DESCRIPTION Domestic hot water outlet 1” M Ø Outlet from boiler 1” M Ø Return to boiler 1” M Ø DHW recirculation 1” M Ø Domestic cold water inlet 1” M Ø Diameter/length of boiler sensor socket 16/180 Quantity/diameter/length of magnesium 1/33/300...
  • Page 8: Recycling And Disposal

    12 RECYCLING AND DISPOSAL The device is primarily composed of: Material Component steel structural work PU (polyurethane) insulation PE (polyethylene) water connection washers ABS (acrylonitrile-butadiene-styrene) lining and covers At the end of the device's useful life, these components must be separated and disposed of according to current regu- lations in the country of installation.