Wall Installation

1. Install the wall mount bracket provided with the unit onto a
solid, non-combustible surface using the appropriate
fasteners. There are five mounting holes on the wall mount
bracket.
• Make sure the fasteners are appropriate for the
installation surface and the weight of the unit.
• locate the unit directly underneath an exhaust hood if
possible. This will ensure total suction of steam
produced during cooking.
• Make sure the unit is at the proper height in an area
convenient for use.
2. Align the mounting slots on the back of the unit with the
hooks on the wall mount bracket. Set the unit on the hooks.
Mounting Slots
Figure 6. Mounting Slots on Back of Unit
3. Have a qualified electrician perform the necessary electrical
connections (refer to "Electrical Connections" in this section
for additional information).

Electrical Connections

The THERM-MAX Salamander must be hardwired to the
electrical supply or have the appropriate cord and/or plug
installed.
WARNING
ELECTRIC ShOCk hAzARD:
• Units supplied without an electrical plug require field
installation of proper plug. Plug must be properly
grounded
and
of
configuration for electrical specifications of unit.
Contact a qualified electrician to determine and install
proper electrical plug.
• Units supplied without an electrical cord and plug
require field installation of proper cord and plug or a
hardwired connection to on-site electrical system.
Connection must be properly grounded and of correct
voltage,
size,
and
specifications of unit. Contact a qualified electrician to
determine and install proper electrical connection.
• When installing a hardwired unit, a 2-pole or 3-pole
switch (depending on unit) must be installed between
unit and main electrical supply. The switch must be
rated properly and have contacts with a minimum
opening distance of 3 mm (1/8").
• Unit must be connected to an equipotential system that
complies with the latest electrical standards.
Form No. TMSCEM-0911
correct
voltage,
size,
configuration
for
electrical
Make sure electrical supply matches the voltage and
frequency rating on the specification label. Incorrect
electrical supply may damage the unit.
hardwired Connection
1. Remove the access panel to expose the power inlet area of
the unit. It is located on the right rear side of the unit when
facing the controls.
Access Panel
Figure 7. location of Power Inlet
2. locate the terminal block inside the unit.
3. Bring power leads from a properly sized circuit breaker or
disconnect switch through the power inlet on the unit.
4. Make the appropriate connections.
• Use copper wire only.
• Tighten connections to a minimum of 4.25 newton
meters (40 inch pounds).
• A grounding screw is provided near the electrical
terminals. An equipment grounding conductor must be
properly connected to it.
5. Replace and secure the access panel.
and
Cord and Plug Connection
On units supplied with a power cord, connect the proper plug to
the cord. Make sure the plug is rated for the specific load and
the plug matches a suitable receptacle.
NOTE: The specification label is located on the side of the unit
near the power inlet. See the label for verification of unit
electrical information.
NOTE: The plug and receptacle must be grounded in
accordance with current standards.