Under a Desk- or Shelf-Mounting

To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm)
Warning
Statement 1076
Under a Desk- or Shelf-Mounting
Step 1
Use the screw template to align the mounting screw holes and also as a guide to make sure that you install the screws
under the desk or shelf with proper clearance.
Step 2
Position the screw template on top of the desk or shelf so that the edge that is marked as CABLE SIDE ENTRY faces
the front of the desk or shelf. This ensures that the power cord faces the rear of the desk or shelf after the switch is installed.
Wait before you attach the screw template to the desk or shelf.
Note
Step 3
Peel the adhesive strip off the bottom of the screw template, and attach it to the top of the desk or shelf.
Step 4
Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the two screw template slots.
Step 5
Insert two screws in the slots on the screw template, and tighten them until they touch the top of the screw template.
Figure 11: Installing the Mounting Screws Under a Desk or Shelf
Step 6
Remove the screw template from underneath the desk or shelf.
Step 7
Place the switch upside down onto the mounting screws, and slide it forward until it locks in place.
Warning
To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm)
Statement 1076
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide