(7) Mounting handles (A) and (B)
(a) Insert the Handle Shaft <91> into handle (A) and fix it with the Screw D4 x 25 <85>.
(b) Insert the Cord <90> and Cord Armor <87> and then fix the Cord Clip <88> with the Screw D4 x 16
<89>. Bring the flat side of the Cord Clip <88> in contact with the Cord <90> when mounting.
(c) Insert the hinge shaft of handle (A) into the hinge hole of the Back Cover <92> and fix handle (A) to
the Transatory Unit <79> with Distance Piece (B) <74> and the Bolt M5 x 12 <73>.
(d) Fit the Filter PCB Ass'y <78>, connectors that connect Pillar Terminal (A) <86> to the Controller
Ass'y <67>, Switch <84>, and Trigger <83> into the positions shown in the figure.
NOTE: Do not reverse the Filter PCB Ass'y <78> orientation.
(e) Put the internal wires in handle (A) and mount handle (B) without getting the internal wires caught
between handles (A) and (B).
• Mounting handles (A) and (B)
<79>
Handle (A)
<84>
<86>
<83>
Connectors that connect
Filter PCB Ass'y <78> to
the Controller Ass'y <67>
-13-
Mount handle (B) without protruding
the internal wires and connectors
from the rib of handle (A).
The blue element of the Filter PCB
Ass'y <78> must be on the back
cover side.