Troubleshooting
Symptom
Unit has shut down
Fault LED
due to an error.
indicator
These items can
(red) is
also be found in
illuminated
Table 8.
(solid).
42
Table 10
Indications
Possible Cause
Error code
Battery voltage too high.
F03
Error code
Both internal fans failed.
F0 1
Error code
High output voltage
F06
(<260 Vac).
Error code
Low output voltage
F58
(>190 Vac).
Error code
F08, F09,
Internal failure.
F53, F57
Error code
Overcurrent or surge.
F5 1
Error code
Bus voltage is too low.
F52
Error code
Output voltage is
F55
unbalanced.
Error code
PV input voltage is
F59
too high.
Troubleshooting
Possible Remedy
Check the wiring and output of the
battery bank with a voltmeter.
Make service arrangements.
Make service arrangements.
Reduce loads to avoid loading down
the output. If this does not work,
make service arrangements.
Make service arrangements.
Remove all power, then reconnect and
restart. If this does not work,
make service arrangements.
Reduce the number of PV modules
in series.