Display
Readings
The left side of the LCD display has three fields of readings.
These readings can be switched to display different data.
The  and  keys (see page 31) proceed through a series
of items. In most cases only two of the three fields are used.
Different markers appear to indicate unit or the type of data.
The items below show examples of each category of display.
The order shown here and on the next page is the order of
the screens when pressing the  and  keys.
INPUT
AC
Input and output AC voltage.
The
V
INPUT marker appear in the
OUTPUT
upper field. The OUTPUT
marker appears in the lower
V
field. V markers appear for
each field. This is the
default screen.
INPUT
AC
Input AC frequency (with
decimal) and output AC
Hz
voltage. The upper field
OUTPUT
displays the Hz marker.
V
The lower field continues to
display output AC voltage.
INPUT
PV
PV voltage and output AC
voltage. The
V
appears. The upper field
OUTPUT
displays a V marker.
V
The lower field continues to
display output AC voltage.
INPUT
PV
PV current (with decimal) and
output AC voltage.
A
The upper field displays
OUTPUT
an A marker.
The lower field continues to
V
display output AC voltage.
INPUT
PV
PV power and output AC
W
voltage. The upper field
displays a W marker.
OUTPUT
The lower field continues to
V
display output AC voltage.
24
marker and the
AC
marker
PV
BATT
PV
Charging current from AC or
PV. The upper field displays
A
the
OUTPUT
INPUT. Either the
marker, or both, may appear.
V
The A marker appears.
The lower field continues to
display output AC voltage.
BATT
PV
Charging power from PV or
W
AC. Either the
marker, or both, may appear.
OUTPUT
The W marker appears.
The lower field continues to
V
display output AC voltage.
BATT
Battery voltage (with decimal).
The upper field displays only
V
the
(See page 23 for the battery
OUTPUT
state of charge display.)
V
The lower field continues to
display output AC voltage.
Output frequency (with
BATT
decimal). This is displayed in
V
the lower field, which also
displays a Hz marker.
OUTPUT
The upper field continues to
display battery voltage.
Hz
marker instead of
BATT
PV
AC
or
or
PV
AC
and V markers.
BATT
900-0248-01-00 Rev A