Technical Description (TED:BSS)
BS-240/241
68
A special setting of the attribute "associatedString" in the command "CREATE
ENVABTSE" for the corresponding site input allows the operator to indicate that the
support of emergency configuration is required for the 3rd party battery backup unit
system.
The string indicates from which source, AC/DC CAN node or site input, the trigger for
the emergency configuration is expected. In case the string pattern is set to
"##ACDC_FAULT", the trigger is expected from the site input of the corresponding
ENVABTSE object. In all other cases the normal behavior is maintained. For simplicity,
there is no check if the string "##ACDC_FAULT" is used for more than one ENVABTSE
object.
If the operator has set the "associatedString" attribute of an ENVABTSE object to
"##ACDC_FAULT" for the AC/DC alarm line, the emergency configuration is deacti-
vated if all trigger sources have ceased their alarm.