Factory Default Settings - WEG MMW03-M22CH User Manual

Energy analyzer
Table of Contents

Advertisement

www.weg.net

5 FACTORY DEFAULT SETTINGS

Menu
Sub Menu 1
Ctr
BASIC
Utr
Conn
VLN ALM
VLL ALM
ALARMS
I ALM
IN ALM
COSQ ALM
PF ALM
ALARMS
FREQ ALM
rLY1
RELAYS
rLY2
DEMAND
dEd.s
bAud
RS485
Id
PrtY
INPUT1
DI INPUT
INPUT2
38 | Energy Analyzer - MMW03-M22CH
Sub
Description
Menu 2
Current transformer ratio
Voltage transformer ratio
Connection type options
Voltage (phase-neutral) alarm
HI
high limit
Voltage (phase-neutral) alarm
LO
low limit
Voltage (phase-neutral) alarm
hYSt
hysteresis value
Voltage (phase-neutral) alarm
dlY.t
delay time
Voltage (phase-phase) alarm high
HI
limit
Voltage (phase-phase) alarm high
LO
low limit
Voltage (phase-phase) alarm
hYSt
hysteresis value
Voltage (phase-phase) alarm
dlY.t
delay time
HI
Current alarm high limit
LO
Current alarm low limit
hYSt
Current alarm hysteresis value
dlY.t
Current alarm delay value
HI
Neutral current alarm high limit
LO
Neutral current alarm low limit
hYSt
Neutral current hysteresis value
dlY.t
Neutral current alarm delay value
HI
cos φ alarm high limit
LO
cos φ alarm low limit
hYSt
cos φ alarm hysteresis value
dlY.t
cos φ alarm delay time
HI
Power factor alarm high limit
LO
Power factor alarm low limit
Power factor alarm hysteresis
hYSt
value
dlY.t
Power factor alarm delay time
HI
Frequency alarm high limit
LO
Frequency alarm low limit
hYSt
Frequency alarm hysteresis value
dlY.t
Frequency alarm delay time
Relay 1 setup
Relay 2 setup
Demand time setup
Baud rate options
Slave ID setup
Parity check setup
tYPE
Digital input 1 options
Digital input 1 detection delay
dLY
time
EdgE
Digital input 1 detection edge
tYPE
Digital input 2 options
Digital input 2 detection delay
dLY
time
Digital input 2 detection edge
Default
Unit
Value
1
-
1.0
-
3P4W
-
0.0
V
0.0
V
5.0
V
5
sn
0.0
V
0.0
V
5.0
V
5
sn
0.0
A
1200/2400/4800/9600/19200/38
0.0
A
0.1
A
5
sn
OFF/TARIFF 2/COUNTER/RUN
0.0
A
0.0
A
0.1
A
RISING/FALLING/BOTH EDG
OFF/TARIFF 2/COUNTER/RUN
5
sn
0.00
-
0.00
-
RISING/FALLING/BOTH EDG
0.01
-
5
sn
0.00
-
0.00
-
0.01
-
5
sn
50.0
Hz
50.0
Hz
2.0
Hz
5
sn
OFF
-
OFF
-
15
dk
1200/2400/4800/9600/19200/38
38400
Baud
1
-
NONE
-
OFF/TARIFF 2/COUNTER/RUN
OFF
-
10
msn
RISING
-
RISING/FALLING/BOTH EDG
OFF/TARIFF 2/COUNTER/RUN
OFF
-
10
msn
RISING
-
RISING/FALLING/BOTH EDG
Setting Range
0.00 - 1.00
0.00 - 1.00
0.00 - 1.00
0 - 60
45.0 - 65.0
45.0 - 65.0
0.0 - 20.0
0 - 60
OFF/LOW/HIGH
OFF/LOW/HIGH
1 - 60
400/57600
1 - 247
NONE/EVEN/ODD
HOUR
10 - 2000
HOUR
10 - 2000
0.00 - 1.00
0 - 60
0.00 - 1.00
0.00 - 1.00
0.00 - 1.00
0 - 60
45.0 - 65.0
45.0 - 65.0
0.0 - 20.0
0 - 60
OFF/LOW/HIGH
OFF/LOW/HIGH
1 - 60
400/57600
1 - 247
NONE/EVEN/ODD
HOUR
10 - 2000
HOUR
10 - 2000