2.4

Video-technical characteristics

We use the AXIS P1367 network camera in a pressure-resistant enclosure. For details,
please refer to the Product Documentation, video-technical data of AXIS
https://www.axis.com/products/axis-p1367
2.5

Other technical data

Permissible ambient temperature
Protection class as per EN
60529/IEC 529
Housing material
Weight
Dimensions
3

Safety Instructions

Please absolutely observe the safety directions stated
in the Ex-installation instructions of the T08 ExCam series!
Quick link:
https://www.samcon.eu/fileadmin/documents/en/22-Ex-Network-Cameras/ExCam-Series-T08-EX-Installation-Manual-2018.pdf
It is absolutely mandatory to observe the national safety regulations and regula-tions
for prevention of accidents, as well as the safety instructions given below in this User
Manual!
Attention!
Cameras of the type T08 ExCam are not suitable for use in zone 0 and
zone 20. The ambient temperature, temperature class and explosion
group as stated on type plate must be observed! Alterations are not per-
mitted! The camera is to be operated in sound conditions and in the in-
tended way.
Attention!
Only original parts of SAMCON Prozessleittechnik GmbH may be used for
repairs. Repairs concerning the explosion protection may only be carried
out in accordance with the nationally applied regulations and by
SAMCON Prozessleittechnik GmbH.
Camera (Ex-d)
0°C ... +60°C (for PoE power supply)
-60°C ... +60°C (for 24 V DC power supply)
IP68 (test conditions: 24h/3m water column 5°C°)
Stainless steel, mat. no. 1.4404
About 8.0 kg
D113mm x 310mm
®
:
Tab. 2-1. Other technical data
Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 6 of 32