Fig. 6-2 Removing the weather protection roof (2/2) (similar illustration)

To open the ExCam XF P1367's stainless steel housing (T07 VA2.3.x.x) of, loosen the
eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings
(DIN 127A) on the rear side of the cable and power supply flange (see Fig. 6-3).
Caution: Do not touch the screw threads with your skin or clothes! On the threads, there
is LOCTITE® 243™ (chemical basis is dimethacrylate ester) applied to prevent the bolt-
ed connection from unintentional loosening because of impacts and vibrations and to
seal them tightly. It is not permitted for the customer to open the front-side sight glass
flange! There is no need of such an action.
Carefully pull out the cable and supply flange to the rear, as straight as possible. Be-
cause of negative pressure, it may be difficult to remove the flange. The cylindrical clear-
ance fit (H8f7 - DIN ISO 286) of the camera body and flange may not be tilted! Risk of
damage to the flame-proof gap (DIN EN 60079-1:2012)!
Fig. 6-3 Opening the ExCam XF P1367 (similar illustration)