25 meters
95 meters
5.3.5

Fusing

PoE power supply requires no fuses.
The power supply fusing depends on the cable cross-section and length.
Attention!
Recommendation for fusing relates to 40W@24VDC at 100 meters
1.5 mm
Attention!
When the heating switches on, high current peaks occur! Use slow-
blow fuses.
Attention!
Please pay attention to the national and international regulations re-
garding selectivity and line protection.
Potential/
Colour
Wire no.
(IEC60757)
L+ / 1
BK
L- / 2
BU
PE
YE/GN
SKDP03-T CABLE EXCAM 25M
(01541-001)
This cable set includes:
25 meters SKDP03-T system cable, digital
1 barrier gland Ex-d
5 ml Loctite 243 screw locking
1 x CAT6 RJ45 industrial plug
1 set of documents
SKDP03-T CABLE EXCAM 95M
(01542-001)
This cable set includes:
95 meters SKDP03-T system cable, digital
1 barrier gland Ex-d
5 ml Loctite 243 screw locking
1 x CAT6 RJ45 industrial plug
1 set of documents
2
Conductor
Voltage
1.5mm
2
,
+24 V DC
stranded wire
2
1.5mm
,
0 VDC / GND
stranded wire
2
1.5mm
,
PE
stranded wire
ASKDP03-T CABLE EXCAM 25M
(01545-001)
This cable set includes:
25 meters ASKDP03-T system cable, digital
1 bolted connection Ex-d
1 bolted connection Ex-e
5 ml Loctite 243 screw locking
1 x CAT6 RJ45 industrial plug
1 set of documents
ASKDP03-T CABLE EXCAM 95M
(01542-001)
This cable set includes:
95 meters ASKDP03-T system cable, digital
1 bolted connection Ex-d
1 bolted connection Ex-e
5 ml Loctite 243 screw locking
1 x CAT6 RJ45 industrial plug
1 set of documents
Tab. 5-4 Available cable kits
Maximum
power
tion/fusing:
40 W of continuous power
Fine-wire fuse
(L+) 4000 mA -T- slow-blow
(high inrush load!)
Tab. 5-5 Recommendation for fusing