In accordance with standard EIA/TIA-568B for 100BaseTX and 24 V DC for terminal
boxes, we recommend the following core wire assignment for the SKDP03-T cable:
Camera (Ex-d)
Colour
(T568B)
SKDP03-T
(IEC60757)
Tx+
WH / OG
Tx-
OG
Rx+
WH / GN
Rx-
GN
(PoE +48 VDC)
WH / BU
(PoE +48 VDC)
BU
(PoE GND)
WH / BN
(PoE GND)
BN
GND/SHD
YE / GN
L+
BK
L-
BU
PE
YE / GN
Video Tutorial:
Please view our video tutorial :
"SAMCON 01 Wiring the cable SKDP03-T to the junction box ExTB-3"
https://go.samcon.eu/v01
Terminal
Cross-
ExTB-3
sectional
surface
1
0.25 mm
2
0.25 mm
3
0.25 mm
4
0.25 mm
5
0.25 mm
6
0.25 mm
7
0.25 mm
8
0.25 mm
2
PE
2.5 mm
9
1.5 mm
2
2
10
1.5 mm
2
PE
1.5 mm

Tab. 5-3. Wire assignment of terminal box ExTB-3

Comment
2
Solid conductor
2
Solid conductor
2
Solid conductor
2
Solid conductor
2
Solid conductor
2
Solid conductor
2
Solid conductor
2
Solid conductor
Flex
L+ 24VDC
L- 24VDC
PE