  • Page 1 ExCam ® XF P1367 User Manual...
  • Page 2: Table Of Contents

    Table of contents Introduction ......................4 Technical data ......................4 Explosion protection .................... 4 Electrical parameters of the camera ..............5 Connection cable Ex-d - Ex-e (SKDP03-T) ............5 Video-technical characteristics ................6 Other technical data .................... 6 Safety Instructions ....................6 Installation ........................
  • Page 3 Fig. 6-1 Removing the weather protection roof (1/2) (this illustration is an example) ..20 Fig. 6-2 Removing the weather protection roof (2/2) (similar illustration) ......21 Fig. 6-3 Opening the ExCam XF P1367 (similar illustration)..........21 Fig. 6-4. Mounting adapter with built-in components ............23 Fig.
  • Page 4: Introduction

    Introduction The ExCam XF P1367 is a powerful mega-pixel IP camera of the latest generation, with 5-megapixel resolution at 3072 x 1728 pixels. It is certified according to ATEX, IECEx and EAC-Ex, and also has MASC certification. The camera has a high-definition televi- sion resolution.
  • Page 5: Electrical Parameters Of The Camera

    Electrical parameters of the camera Supply of 24 V DC for the heating: Voltage supply: 24 V DC Power consumption: approx. 40W@-60°C (temperature-dependent) Power supply of the camera over Ethernet (PoE): Voltage supply: PoE, IEEE 802.3af/802.3at type 1 class 3 Reference voltage: +48 V DC (44...54 V DC) Maximum power consumption:...
  • Page 6: Video-Technical Characteristics

    Video-technical characteristics We use the AXIS P1367 network camera in a pressure-resistant enclosure. For details, ® please refer to the Product Documentation, video-technical data of AXIS https://www.axis.com/products/axis-p1367 Other technical data Camera (Ex-d) 0°C … +60°C (for PoE power supply) Permissible ambient temperature -60°C …...
  • Page 7: Installation

    Attention! Prior to installation, take external sources of heat or cold into account! The temperature ranges prescribed for storage, transportation, and operating must be adhered to! Attention! Observe the warnings given on the type plate: “WARNING – DO NOT OPEN IN HAZARD AREAS“ “WARNING –...
  • Page 8: Tab. 4-1 Mounting Accessories

     Use appropriate tools and aids.  When working, ensure a safe stand.  Make sure that any static charge is avoided Attention! Please observe the national security, installation and accident preven- tion regulations (e.g. DIN EN 60079-14) and the safety instructions in this User Manual, as well as the ones in the Installation Guidelines! Attention! Adhere to the provisions of the IECEx, ATEX and EX installation in-...
  • Page 9: Electrical Connection

    (right) (see Figure 5.1). The cross-section of the equipotential bonding should comply with the National Ground Rules (at least 4 mm Fig. 5-1 ExCam XF P1367 Equipotential Bonding Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 9 of 32...
  • Page 10: Connection And Fusing

    IEEE 802.3af and 802.3at type 1 Class 3 ("classification current: 26-30 mA @48VDC, max. feed-in power (power source equipment): 15.4 W, maximum offtake (power device): 6.49 - 12.95 W"). The data transfer of the ExCam XF P1367 series is done via a 100 Mbit/s Ethernet connection (100BASE-TX).
  • Page 11: Network Interface / Plug Assignment (Rj45)

    5.2.1 Network interface / plug assignment (RJ45) Standardly, of the camera’s cable end is furnished with an RJ45 Ethernet plug with Pow- er over Ethernet (PoE). This plug (Fig. 5-3) should be coupled with the RJ45 PoE socket of the network device (PSE). Prior to connecting it to the camera, the network device can already be supplied with power, hence you need not to observe any “power ON”...
  • Page 12: Tab. 5-3. Wire Assignment Of Terminal Box Extb-3

    In accordance with standard EIA/TIA-568B for 100BaseTX and 24 V DC for terminal boxes, we recommend the following core wire assignment for the SKDP03-T cable: Camera (Ex-d) Colour Terminal Cross- Comment (T568B) SKDP03-T ExTB-3 sectional surface (IEC60757) WH / OG 0.25 mm Solid conductor 0.25 mm...
  • Page 13: Fig. 5-5 Sample Circuit Of Terminal Box Extb-3

    Fig. 5-5 Sample circuit of terminal box ExTB-3 Fig. 5-6 Photo of the occupied terminal box ExTB-3 Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 13 of 32...
  • Page 14: Example: External Connection And Fusing Via The Terminal Box

    Attention! Introduce the foiling up to about 15 mm to the terminals, in order to pre- vent alien crosstalk. Make sure that the foiling cannot cause any short circuit of the data pairs! Attention! Bring the twisted pair composite approximately 10mm close to the termi- nals, in order to ensure the interference immunity.
  • Page 15: Example: Routing Via Exconnection Rail (Optional Accessories)

    In the case of direct routing from ExTB-3 to the safe area, the power supply and the volt- age signal are led from the safe area to the terminal box. Please observe the terminal box assignment, as described above. Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 &...
  • Page 16: Appropriate Cables & Cable Entries

    5.3.3 Appropriate cables & cable entries An integral part of the device safety is the correct selection of the cables, wires and cable entries. Attention! Cables and wires must comply with the requirements of the IEC 60079- 0/1/7 & 14. Attention! The supply line must have a sufficient cross-section.
  • Page 17: Cable Kits - "Plug And Play" Connection Packages

    5.3.4 Cable kits - "plug and play" connection packages As an option, there are various cable kits for different cables are available in different lengths. The connection packages include everything you need for a professional system installation:  10/25/95 m SKDP03-T system cable, digital (a) ...
  • Page 18: Fusing

    SKDP03-T CABLE EXCAM 25M ASKDP03-T CABLE EXCAM 25M 25 meters (01541-001) (01545-001) This cable set includes: This cable set includes: 25 meters SKDP03-T system cable, digital 25 meters ASKDP03-T system cable, digital 1 barrier gland Ex-d 1 bolted connection Ex-d 5 ml Loctite 243 screw locking 1 bolted connection Ex-e 1 x CAT6 RJ45 industrial plug...
  • Page 19: Tests Prior To Switching On The Voltage

    5.3.6 Tests prior to switching on the voltage Attention! Prior to starting the device, perform all tests as indicated by the na- tional regulations. Furthermore, check the correct function and instal- lation of the device in accordance with this User Manual and other ap- plicable regulations.
  • Page 20: Opening The Pressure-Resistant Housing

    Pay attention not to damage the housing seals. Keep them clean! If the ExCam XF P1367 is equipped with a weather protection roof (optional accessory), remove the roof before you start working! To do so, untighten the 4x8mm lens screws M4*0.7 at the front and rear sides of the bracket holders (Fig.
  • Page 21: Fig. 6-2 Removing The Weather Protection Roof (2/2) (Similar Illustration)

    Fig. 6-2 Removing the weather protection roof (2/2) (similar illustration) To open the ExCam XF P1367’s stainless steel housing (T07 VA2.3.x.x) of, loosen the eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings (DIN 127A) on the rear side of the cable and power supply flange (see Fig. 6-3).
  • Page 22 Attention: The mounting adapter with the housing’s PTC heater, camera module and op- tics, as well as the CB06 temperature control and (if applicable) auxiliary relays and ter- minal box are fixed on the cable and supply flange. Dealing with these components, too, you have to work very carefully and precisely in order to avoid canting and damage to the in-built components! Caution: Do not touch the cylindrical fit surface with your skin or clothes! On the surface,...
  • Page 23: Removing/Inserting A Sd Memory Card

    Removing/inserting a SD memory card Note: The ExCam XF P1367 disposes of a micro SDHC memory card slot (see Fig. 6-4 1). Saved video files can be played and deleted via the web interface. They are also availa- ble in a download list. Moreover, the videos available on the memory card can also be accessed via an FTP server in the network.
  • Page 24: Status Led

    The user can see the Status LED (Fig. 6-4) only if the camera housing is open. Hardware Reset To re-set all parameters of the ExCam XF P1367 (including the IP address) to default setting, a hardware reset has to be carried out.
  • Page 25: Battery

    - crosswise and evenly! Battery ExCam XF P1367 is equipped with a high-temperature resistant Panasonic button cell BR2330A/VAN. This cell supplies energy to the internal real time clock (RTC). The cus- tomer is not allowed to replace the battery! In this case, please contact the manufacturer.
  • Page 26: Settings Of The Lens

    Settings of the lens The ExCam XF P1367 lens can be set up only via the web interface or the visualization software. The user cannot do any mechanical settings on at remote zoom lens. To con- figure the focus and tele-range, you can use the control function (slider) via the web inter- face and mouse command (see Fig.
  • Page 27: Network Access And Visualization

    The focus of the ExCam XF P1367 network camera is optimised by the manufacturer to about 10 m object distance. The complete viewing angle is located in the "wide" area. This means a horizontal viewing angle of 98°. Usially, no adjustment is required. To focus the objects at a smaller or greater distance, or to change the zoom range (wide ->...
  • Page 28: Browser Support

    Assigning the IP address The ExCam XF P1367 is intended for use in an Ethernet network and requires an IP ad- dress to access and control it. In most of today’s networks, a DHCP server is integrated. This server automatically assigns an IP address.
  • Page 29: Password/ Identification

    ExCam IP1365 ExCam XF P1367 AXIS P1367 Fig. 8-1 Axis IP Utility Password/ Identification The following user name is set at the factory: root The following password is set at the factory: root Maintenance/ Modification The applicable regulations for the maintenance and servicing of electrical devices in po- tentially explosive atmospheres must be adhered to.
  • Page 30: Repair

    Repair Repairs may only be carried out with original parts of SAMCON Prozessleittechnik GmbH. Damaged pressure-resistant housings have to be replaced completely. If in doubt, send the part in question back to SAMCON Prozessleittechnik GmbH. Repairs concerning the explosion protection must only be carried out in accordance with nationally applied regulations by SAMCON Prozessleittechnik GmbH or by an electrical technician authorized by SAMCON Prozessleittechnik GmbH.
  • Page 31: Certificates And Further Documentation

    If you wish additional technical information, please contact us at: support@samcon.eu Certificates and further documentation Certificates and further documentation are available in the download area at the product website: Quick link: https://www.samcon.eu/en/products/network/excam-xf-p1367/ Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 31 of 32...
  • Page 32 Schillerstrasse 17, 35102 Lohra-Altenvers, Germany www.samcon.eu, info@samcon.eu Phone: +49 6426 9231-0, fax: - 31...