Retrofit and reinstall MO drives

If the customer is not keeping 4 MO drives for a mixed-media configuration, do not follow the
procedures in this section. Instead, continue with
If the customer is keeping their MO drives, they must be retrofitted and reinstalled in the
jukebox after the jukebox is converted and the UDO drives are installed.
Note:
8x MO drives are not supported in a jukebox with UDO technology.
The procedures for retrofitting and reinstalling are as follows.
1. Remove the SCSI and ACI ribbon cables from the MO drives. The power cable will be
2. On each drive:
3. Install the media detect station into the 11/12 drive location.
Note:
module down and slightly to the right.
4. Slide the MO drives into drive locations 7/8 and 9/10.
5. Secure the MO drives to the jukebox using 2 T-20 torx screws, 1 on each side of each
6. Connect the drive cables to the interposer board (see
7. Attach the jumper cable at drive location 11/12.
8. Add the configuration module if required. If the customer already has a configuration
9. Attach the interposer board power cables.
10. Attach the terminator.
11. Attach the label cover over the old unused HVD and S/E ports of the buffer board.
12. Assure the new LVD terminator is in place, and notify the customer that the HVD and S/E
3800ux/7100ux Optical Jukebox Conversion Guide
Only 14x MO drives can be upgraded and included in a mixed-media jukebox. 2x, 4x, and
re-used.
a. Attach the 50-pin to 68-pin converter (P/N 1200-1997) to the SCSI port of the drive.
b. Attach the LVD SCSI cable (larger of the ribbon cables, P/N AA969-63005) to the
68-pin side of the 50-pin to 68-pin converter.
c. Attach the autochanger interface cable (smaller of the ribbon cables, P/N
AA969-63007) to the drive.
If you are having problems installing the drive module in drive location 11/12, push the
drive.
module, the one from the kit is not needed. You may return it to your sales representative
or discard it.
terminator can no longer be used.
Convert an MO Jukebox to UDO or Mixed-Media Technology