Emerson Rosemount 5300 Series Product Data Sheet page 22

Superior performance guided wave radar level and interface transmitter
Hide thumbs Also See for Rosemount 5300 Series:
Table of Contents

Advertisement

Rosemount 5300 Series
Temperature and Pressure Limits
Ambient Temperature
Storage Temperature
22
The maximum and minimum ambient temperature for the electronics depends on the process
temperature (as described by the graph below) and on the approval (see "Product Certifications" on
page 36).
Ambient Temperature °F (°C)
-320 (-196)
Note:
• Nozzle insulation for the HTHP version (Operating Temperature and Pressure code H) should
not exceed 4 in. (10 cm)
• The temperature range for the optional Integral Display is -4 °F to 158 °F (-20 °C to 70 °C)
• In applications where the ambient temperature exceeds the limits of the electronics, a Remote
Mounting connection can be used. The maximum temperature for the Remote Mounting
connection at the vessel connection point is 302 °F (150 °C)
-58 °F to 194 °F (-50 °C to 90 °C)
With Integral Display: -40 °F to 185 °F (-40 °C to 85 °C)
-40 (-40)
-17 (-27)
-40 (-40)
Product Data Sheet
00813-0100-4530, Rev DA
December 2010
Process Temperature °F (°C)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5302Rosemount 5301Rosemount 5303

Table of Contents