Summary of Contents for Gree TOSOT MOMA-19
Page 1
Owner's Manual Original Instructions Local air conditioner 020$ Model: Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
Content Operation Notices The Refrigerant ......................1 Safety Warning ......................2 Operation Environment ....................3 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Using the remote controller ..................7 Buttons on Remote Controller .................8 Introduction for Icons on Display Screen ..............8 Introduction for Buttons on Remote Controller ............9 Function Introduction for Combination Buttons ............12 Operation Guide .....................13...
Page 3
Explanation of Symbols ,QGLFDWHV D KD]DUGRXV VLWXDWLRQ WKDW LI QRW DYRLGHG ZLOO DANGER UHVXOW LQ GHDWK RU VHULRXV LQMXU\ ,QGLFDWHV D KD]DUGRXV VLWXDWLRQ WKDW LI QRW DYRLGHG FRXOG WARNING UHVXOW LQ GHDWK RU VHULRXV LQMXU\ ,QGLFDWHV D KD]DUGRXV VLWXDWLRQ WKDW LI QRW DYRLGHG PD\ CAUTION UHVXOW LQ PLQRU RU PRGHUDWH LQMXU\ ,QGLFDWHV LPSRUWDQW EXW QRW KD]DUGUHODWHG LQIRUPDWLRQ...
Appliance filled with flammable gas R290. Before install and use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Safety Warning Do not through sundries into the air duct. If there are sundries get into the air duct, please contact the professionals to deal with it. Do not use an extension cord. Operation Environment r i a i t i t a r i h t 16°C ~ 35°C.
Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube + / - button Cool mode indicator Swing indicator Wifi indicator Dry mode indicator Fan mode indicator Swing button Heat mode indicator Wifi button (Cool&Heat Unit only) Fan speed indicator Fan button ON/OFF button Mode button...
Page 9
Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below sequence: Cool Heat (Cool&Heat Unit only) Cool: Under this mode, cooling mode indicator is bright. Dual-8 nixie tube displays set temperature. Temperature setting range is 16 °C~30°C Dry: Under this mode, drying mode indicator is bright.
Page 21
Malfunction analysis Malfunction code ERROR Troubleshooting CODE Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. 1.Check if the unit is under high-temperature and high-humidity environment; if ambient temperature is too high, power off the unit and then energize it for operation after the ambient temperature drops to 35℃below.
The appliance shall be installed in accordance with national wiring regulations. To be in compliance with IEC 61000-3-11, impedance value of power-supply system connected to product must be less than or equal to the allowable maximum value of |Zsys| in the following sheet: 0.13 020$ Preparation before Installation...
Optional 3 Joint D Joint E Joint F Joint G Plastic Cover Tools needed for installation Cross screwdriver Straight screwdriver Guge Scissors Pencil Install Power cord Hooks Assemble the power cord hooks at the back of the unit with screws (the direction of power cord hooks is as shown in following fig).
Wind the power cord around the SRZHU FRUG KRRNV. Removing Collected Water There are 2 ways to remove collected water: Use the drainage option from the lower hole. In Cool, Dry or Heat mode operating, the condensation water will be drained to the chassis.
Page 26
Removing Collected Water Use the continuous drainage option from the middle hole NOTICE: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
Installation of Heat Discharge Pipe Note of Installingheat discharge pipe correct correct correct wrong The length of the heat discharge pipe is less than 1m. It is recommended to use it with shortest length. When installing,heat discharge pipe should be as flat as possible. Don’t prolong the pipe or connect it with other heat discharge pipe.
Page 28
Installation of Heat Discharge Pipe should not be over 130cm from floor). would easily cause malfunction.)
Page 29
Installation of Heat Discharge Pipe Optional 1: Installation in a double window 1. Connect joint B to joint C . Joint B Joint C 2. Rotate joint A and joint B+C into the two ends of heat discharge pipe. Joint A Heat discharge pipe Joint B+C 3.
Page 33
Installation of Heat Discharge Pipe 7. Connect joint B to joint C . Joint B Joint C 8. Rotate joint A and joint B+C into the two ends of heat discharge pipe. Clockwise Anti-clockwise Joint A Heat discharge pipe Joint B+C 9.
Page 37
Installation of Heat Discharge Pipe Connect joint B to joint C . Joint B Joint C 8. Rotate joint A and joint B+C into the two ends of heat discharge pipe. Clockwise Anti-clockwise Joint A Heat discharge pipe Joint B+C 9.
Page 38
Installation of Heat Discharge Pipe Optional 3: Installation in WKH window 1. Rotate joint A and joint D into the two ends of heat discharge pipe. 7KHQ URWDWH MRLQW ( WR MRLQW ' FRQQHFW WLJKWO\ -oint ( -oint A +eat discharge pipe -oint D 2.
Page 39
Installation of Heat Discharge Pipe Optional 3-2: Installation in the wall 1. Rotate joint A and joint D into the two ends of heat discharge pipe. Joint A Heat discharge pipe Joint D 2. Insert joint A of heat Clasp discharge pipe (the The side with "TOP"...
Page 40
Installation of Heat Discharge Pipe Optional 3-3: Installation in immovable window 1. Rotate joint A into the ends of heat discharge pipe. Joint A Heat discharge pipe 2. If the window is immovable, cut a hole to install joint F and joint G tightly. Inside Outside Joint G...
Page 41
Installation of Heat Discharge Pipe 4. Insert joint A of heat discharge pipe (the side with "TOP" is upwards) into the groove until you hear a sound. Clasp the side with "TOP" is upwards Groove...
Disassembly of Heat Discharge Pipe Optional 1: Disassemble for installation in double window Remove joint A: Press the clasp and lift joint A upwards to remove it. Clasp Upwards Disassemble Joint A Remove joint B+C from outdoors. Joint B+C...
Page 43
Disassembly of Heat Discharge Pipe Optional 2: Disassemble for installation in sash window 1. Remove joint A: Press the clasp and lift joint A upwards to remove it. Clasp Upwards Disassemble Joint A 2. Remove the window adapter. Pull out and remove the window adapter by pushing down two “PUSH”...
Page 44
Disassembly of Heat Discharge Pipe Optional 3-1: Disassembly for installation in window 1. Remove joint A: 2. Remove joint D: Press the clasp and lift joint A upwards to remove joint D from joint E. remove it. Clasp Upwards Disassemble Joint A Joint D Joint E...
Page 45
Disassembly of Heat Discharge Pipe 3. When heat discharge pipe is removed, Install the plastic cover into joint D in case of the insect into the house. Optional 3-3: Disassembly for installation in immovable window 1. Remove joint A: Press the clasp and lift joint A upwards to remove it. Clasp Upwards Disassemble...
Disassembly of Heat Discharge Pipe 3. When heat discharge pipe is removed, Install the plastic cover into joint F in case of the insect into the house . Plastic Cover Operation Test Put through the power supply and then press ON/OFF button on remote contro- ller to start the unit.
Specialist’s Manual Aptitude requirement for maintenance man(repairs should be done only be specialists). a. All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. b.
Page 49
Specialist’s Manual Refrigeration equipment Checking Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
Page 50
Specialist’s Manual Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications. NOTE : The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment.
Page 51
Specialist’s Manual The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants, the system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems. For appliances containing flammable refrigerants, flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
Page 52
Specialist’s Manual f) Make sure that cylinder is situated on the scales before recovery takes place. g) Start the recovery machine and operate in accordance with manufacturer's instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge). i) Do not exceed the maximum working pressure of the cylinder, even temporarily.