Gree MULTI24HP230V1EO Installation & Owner's Manual
Gree MULTI24HP230V1EO Installation & Owner's Manual

Gree MULTI24HP230V1EO Installation & Owner's Manual

Split type wall-mounted air conditioner
Hide thumbs Also See for MULTI24HP230V1EO:

Advertisement

Quick Links

Change for life
Installation & Owner's Manual
Original Instructions
Split Type Wall-mounted Air Conditioner
Model:
MULTI18HP230V1EO
MULTI24HP230V1EO
MULTI30HP230V1EO
MULTI36HP230V1EO
MULTI42HP230V1EO
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact your local
distributor or visit www.greecomcomfort.com/resources for the
electronic version.

Advertisement

Table of Contents
loading

Summary of Contents for Gree MULTI24HP230V1EO

  • Page 1 Change for life Installation & Owner's Manual Original Instructions Split Type Wall-mounted Air Conditioner Model: MULTI18HP230V1EO MULTI24HP230V1EO MULTI30HP230V1EO MULTI36HP230V1EO MULTI42HP230V1EO Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
  • Page 2: Table Of Contents

    In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice. CONTENTS GENERAL INFORMATION Conformity And Range Warning The Instructions Before Use Name of Parts Outdoor Unit Working Temperature Range Electrical Connections Installing The Outdoor Unit...
  • Page 3: Conformity And Range

    EXPLANATION OF SYMBOLS GENERAL INFORMATION Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 4: Warning

    GENERAL INFORMATION WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 GENERAL INFORMATION WARNING If the air conditioner operates under abnormal conditions, it may cause malfunction,electric shock or fire hazard. When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal. Do not step on top panel of outdoor unit, or put heavy objects.
  • Page 6 GENERAL INFORMATION WARNING The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
  • Page 7: The Instructions Before Use

    THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING When having a burning smell or The power supply must adopt the Never cut off or damage power ★ ★ ★ smoke,please turn off the power special circuit that with air switch cables and control wires. If the supply and contact with the ser- protection and assure it has enou- power cable and signal control...
  • Page 8: Name Of Parts

    NAME OF PARTS GENERAL INFORMATION WARNING Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. any case. Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
  • Page 9: Electrical Connections

    ELECTRICAL CONNECTIONS INSTALLER MULTI18HP230V1EO Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. Remove the cable clamp, connect the power connection cable with the terminal at the row of Wrong wire connection may cause malfunction of connection and fix the connection.
  • Page 10 (Caution: please do not use the fuse only for protect the circuit) Air-conditioner Air switch capacity MULTI24HP230V1EO To unit A To unit B To unit C L1 L2 Power cord...
  • Page 11 ELECTRICAL CONNECTIONS INSTALLER Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. Remove the cable clamp, connect the power connection cable with the terminal at the row of Wrong wire connection may cause malfunction of connection and fix the connection.
  • Page 12 ELECTRICAL CONNECTIONS INSTALLER Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. Remove the cable clamp, connect the power connection cable with the terminal at the row of Wrong wire connection may cause malfunction of connection and fix the connection.
  • Page 13: Installing The Outdoor Unit

    INSTALLING THE OUTDOOR UNIT INSTALLER Location Caution: Installation Must be Performed in Accordance with the NEC/CEC by Authorized Use bolts to secure the unit to a flat, solid floor. Personnel Only. When mounting the unit on a wall or the roof, make Install the drain fitting and the drain hose sure the support is firmly secured so that it cannot (for model with heat pump only)
  • Page 14: Maintenance

    MAINTENANCE INSTALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. Do not use mineral oils to clean the unit. INSTALLATION DIMENSION DIAGRAM INSTALLER The installation must be done by trained and qualified service personnel with reliability according to this manual.
  • Page 15: Check After Installation

    CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises May cause unsatisfactory cooling (heating) Has the gas leakage been checked? effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? Is the drainage smooth?
  • Page 16 U.S. CONTACT INFORMATION TRADEWINDS, LLC www.greecomfort.com/resources E-mail: info@twclimate.com Contractor Support 888-850-7928 | Mon–Fri 8AM-5PM EDT GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com CAT NO: GREE_MULTI_GEN2_INSTALL & OWNERS_02272023...

Table of Contents