Gree GMV-ND100L/A-T Service Manual
Gree GMV-ND100L/A-T Service Manual

Gree GMV-ND100L/A-T Service Manual

Multi variable air conditioners indoor units
Hide thumbs Also See for GMV-ND100L/A-T:
Table of Contents

Advertisement

Quick Links

Multi Variable Air Conditioners
Indoor Units
(GC202209-XXI)
Capacity: 1500W~56000W
Rated Frequency: 50/60Hz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMV-ND100L/A-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gree GMV-ND100L/A-T

  • Page 1 Multi Variable Air Conditioners Indoor Units (GC202209-XXI) Capacity: 1500W~56000W Rated Frequency: 50/60Hz...
  • Page 2: Table Of Contents

    CONTENTS PRODUCT ........................... 1 1 Product List ........................2 1.1 Floor Standing Type ........................ 2 1.2 High Static Pressure Duct Type ....................2 1.3 Low Static Pressure Duct Type ....................2 1.4 4-way Cassette ........................3 1.5 Compact 4-way Cassette ......................4 1.6 360°Air Discharge Compact Cassette ..................
  • Page 3 3.13 Console Type Indoor Unit ....................36 3.14 Wall Mounted Type Indoor Unit ................... 37 3.15 Super High Static Pressure Duct Type Indoor Unit.............. 58 3.16 AHU-KIT Type ........................61 3.17 Concealed Floor Standing Type ..................64 3.18 360°Air Discharge Cassette ....................65 3.19 Heat Storage Module ......................
  • Page 4 3.5 Installation of Compact 4-way Cassette Type Unit .............. 125 3.6 Installation of 360°Air Discharge Compact Cassette Type Unit ........... 127 3.7 Installation of Compact 2-way Cassette Type Unit .............. 129 3.8 Installation of Compact 1-way Cassette Type Unit .............. 132 3.9 Installation of Floor Ceiling Type Unit ..................
  • Page 5 3.12 Air Handler Type Indoor Unit ..................... 215 3.13 Console Type Indoor Unit ....................216 3.14 Wall Mounted type Indoor Unit ..................216 3.15 Super High Static Pressure Duct Type Indoor Unit............221 3.16 AHU-KIT Type ........................224 3.17 Concealed Floor Standing Type ..................226 3.18 360°Air Discharge Cassette Type ..................
  • Page 6 5.12 Console Type Indoor Unit ....................372 5.13 Wall Mounted type Indoor Unit ..................374 5.14 Super High Static Pressure Duct Type Indoor Unit............418 5.15 AHU-KIT Type ........................434 5.16 Concealed Floor Standing Type ..................443 5.17 360°Air Discharge Cassette Type ..................448 5.18 Heat Storage Module ......................
  • Page 7: Product

    GREE Multi Variable Air Conditioners Indoor Units PRODUCT...
  • Page 8: Product List

    Multi Variable Air Conditioners Indoor Units 1 Product List 1.1 Floor Standing Type Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND100L/A-T CM300N0060 10.0 11.0 220-240V ~50Hz R410A 208-230V ~60Hz GMV-ND140L/A-T CM300N0070 14.0 15.0 1.2 High Static Pressure Duct Type...
  • Page 9: 4-Way Cassette

    GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND18PLS/C-T CM810N2030 GMV-ND22PLS/C-T CM810N1800 GMV-ND25PLS/C-T CM810N1810 GMV-ND28PLS/C-T CM810N1770 GMV-ND32PLS/C-T CM810N1820 GMV-ND36PLS/C-T CM810N1760 GMV-ND40PLS/C-T CM810N1830 GMV-ND45PLS/C-T CM810N1740 GMV-ND50PLS/C-T CM810N1840 GMV-ND56PLS/C-T CM810N1850 GMV-ND63PLS/C-T CM810N1730...
  • Page 10: Compact 4-Way Cassette

    GREE Multi Variable Air Conditioners Indoor Units 1.5 Compact 4-way Cassette Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND22T/B-T CM500N0610 GMV-ND28T/B-T CM500N0620 220-240 GMV-ND36T/B-T CM500N0630 V~50Hz R410A 208-230 GMV-ND45T/B-T CM500N0640 V~60Hz GMV-ND50T/B-T CM500N0600 GMV-ND56T/B-T CM500N0650 1.6 360°Air Discharge Compact Cassette...
  • Page 11: 1-Way Cassette

    GREE Multi Variable Air Conditioners Indoor Units 1.8 1-way Cassette Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND22TD/A-T CM502N0140 GMV-ND28TD/A-T CM502N0100 GMV-ND36TD/A-T CM502N0110 220-240V GMV-ND45TD/A-T CM502N0120 ~50Hz GMV-ND50TD/A-T CM502N0130 R410A 208-230V GMV-ND56TD/A-T CM502N0171 ~60Hz GMV-ND63TD/B-T CM503N1060...
  • Page 12: Slim Duct Type

    GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Model Product Code Capacity Capacity Refrigerant Appearance Supply GMV-NX224P/A (X2.0) -M CM800N3620 22.4 16.0 380-415V GMV-NX280P/A (X2.5) -M CM800N3630 28.0 20.0 R410A ~50Hz GMV-NX280P/A (X3.0) -M CM800N3640 28.0 20.0 380-415V GMV-NX450P/A (X4.0) -M...
  • Page 13: Air Handler Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 1.12 Air Handler Type Indoor Unit Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-NR71A/A-D CM810N0200 GMV-NR90A/A-D CM810N0210 10.0 208-230 GMV-NR100A/A-D CM810N0220 10.0 11.0 R410A V~60Hz GMV-NR112A/A-D CM810N0230 11.2 12.5...
  • Page 14 GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-N22G/A8A-K CM100N1770 GMV-N28G/A8A-K CM100N1780 GMV-N36G/A8A-K CM100N1790 GMV-N45G/A8A-K CM100N1800 220-240V~5 R410A GMV-N50G/A8A-K CM100N1810 GMV-N56G/A8A-K CM100N1820 GMV-N63G/A8A-K CM100N1830 GMV-N71G/A8A-K CM100N1840 GMV-N22G/B3A-K CM100N2460 GMV-N28G/B3A-K CM100N2470...
  • Page 15 GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-N22G/A2A-D CM100N1930 GMV-N28G/A2A-D CM100N1940 GMV-N36G/A2A-D CM100N1950 GMV-N45G/A2A-D CM100N1960 208-230V~6 R410A GMV-N50G/A2A-D CM100N1970 GMV-N56G/A2A-D CM100N1980 GMV-N63G/A2A-D CM100N1990 GMV-N71G/A2A-D CM100N2000 GMV-N22G/A4A-D CM100N1610 GMV-N28G/A4A-D CM100N1620...
  • Page 16 GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-N22G/B3A-D CM100N2380 GMV-N28G/B3A-D CM100N2390 GMV-N36G/B3A-D CM100N2400 GMV-N45G/B3A-D CM100N2410 208-230V~6 R410A GMV-N50G/B3A-D CM100N2420 GMV-N56G/B3A-D CM100N2430 GMV-N63G/B3A-D CM100N2440 GMV-N71G/B3A-D CM100N2450 GMV-ND22G/A3A-T CM100N2560 GMV-ND28G/A3A-T CM100N2600...
  • Page 17: Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND15G/B4B-T CM100N3280 GMV-ND18G/B4B-T CM100N3290 GMV-ND22G/B4B-T CM100N2770 GMV-ND28G/B4B-T CM100N2780 GMV-ND36G/B4B-T CM100N2760 220- GMV-ND45G/B4B-T CM100N2790 240V~50Hz GMV-ND50G/B4B-T CM100N2800 R410A 208- GMV-ND56G/B4B-T CM100N2810 230V~60Hz GMV-ND63G/B4B-T...
  • Page 18: Ahu-Kit Type

    GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply GMV-ND56PHS/B-T CM810N0380 220-240V GMV-ND63PHS/B-T CM810N0390 ~50Hz R410A 208-230V GMV-ND71PHS/B-T CM810N0400 ~60Hz GMV-ND80PHS/B-T CM810N0410 GMV-ND90PHS/B-T CM810N0420 10.0 GMV-ND100PHS/B-T CM810N0430 10.0 11.2 220-240V GMV-ND112PHS/B-T CM810N0440 11.2...
  • Page 19: Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply 220-240V ~50Hz GMV-N560U/B-T CN750N0130 56.0 63.0 R410A 208-230V ~60Hz GMV-N36U/C-T CN750N0190 220-240V ~50Hz GMV-N71U/C-T CN750N0200 R410A 208-230V ~60Hz GMV-N140U/C-T CN750N0180 14.0 16.0...
  • Page 20: 360°Air Discharge Cassette

    GREE Multi Variable Air Conditioners Indoor Units 1.18 360°Air Discharge Cassette Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply 220-24 GMV-ND22T/C-T CM500N1680 0V~50 GMV-ND28T/C-T CM500N1660 R410A 208-23 GMV-ND36T/C-T CM500N1670 GMV-ND45T/C-T CM500N1650 60Hz GMV-ND50T/C-T CM500N1640 GMV-ND56T/C-T CM500N1630 GMV-ND63T/C-T...
  • Page 21: Heat Storage Module

    GREE Multi Variable Air Conditioners Indoor Units 1.19 Heat Storage Module Cooling Heating Power Capacity Capacity Model Product Code Refrigerant Appearance Supply 220-24 0V~50 XRZ180L/A-T CM810N2250 R410A 208-23 0V~60 1.20 High Static Pressure Duct Type Indoor Unit Cooling Heating Power...
  • Page 22: Nomenclature

    □ □ □ Description Options Product code GMV - Gree Multi VRF Units Indoor unit code Indoor unit - N D - DC motor Motor type NULL - AC motor R - pure heat pump/ all heat exchanger with cooling function...
  • Page 23: Specifications

    GREE Multi Variable Air Conditioners Indoor Units 3 Specifications 3.1 Floor Standing Type Model GMV-ND100L/A-T GMV-ND140L/A-T Cooling capacity 10.0 14.0 Heating capacity 11.0 15.0 Circulating air volume m³/h 1870 1870 Noise dB(A) 220-240V~50Hz 220-240V~50Hz Power supply 208-230V~60Hz 208-230V~60Hz Cooling Rated...
  • Page 24: High Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 3.2 High Static Pressure Duct Type GMV-ND5 GMV-ND6 GMV-ND7 GMV-ND80 GMV-ND90 GMV-ND100 Model 6PHS/A-T 3PHS/A-T 1PHS/A-T PHS/A-T PHS/A-T PHS/A-T Cooling capacity 10.0 Heating capacity 10.0 11.2 Air volume m³/h 1000 1000 1100 1100...
  • Page 25: Low Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units ② Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6 °C WB; connection pipe length: 5 m, without height drop between units. 3.3 Low Static Pressure Duct Type GMV-ND GMV-ND GMV-ND...
  • Page 26 GREE Multi Variable Air Conditioners Indoor Units GMV-ND6 GMV-ND7 GMV-ND8 GMV-ND9 GMV-ND1 GMV-ND1 GMV-ND1 GMV-ND1 Model 3PLS/A-T 1PLS/A-T 0PLS/A-T 0PLS/A-T 00PLS/A-T 12PLS/A-T 25PLS/A-T 40PLS/A-T Liquid pipe Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Pipe diameter Gas pipe Φ15.9 Φ15.9 Φ15.9...
  • Page 27 GREE Multi Variable Air Conditioners Indoor Units GMV-ND40PL GMV-ND45PL GMV-ND50PL GMV-ND56PL GMV-ND63PL GMV-ND71PL Model S/C-T S/C-T S/C-T S/C-T S/C-T S/C-T 1010×462 1010×462 1010×462 1010×462 1010×462 1310×462 Dimensions W×D×H ×200 ×200 ×200 ×200 ×200 ×200 Net weight Main body GMV-ND80P GMV-ND90P...
  • Page 28: 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units GMV-ND4 GMV-ND4 GMV-ND5 GMV-ND5 GMV-ND6 GMV-ND7 GMV-ND8 Model 0PLS/C1-T 5PLS/C1-T 0PLS/C1-T 6PLS/C1-T 3PLS/C1-T 1PLS/C1-T 0PLS/C1-T Cooling capacity Heating capacity Unit external static 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~50 15/0~30 pressure ³ Air volume...
  • Page 29 GREE Multi Variable Air Conditioners Indoor Units GMV-ND2 GMV-ND3 GMV-ND4 GMV-ND5 GMV-ND5 GMV-ND6 GMV-ND7 Model 8T/A-T 6T/A-T 5T/A-T 0T/A-T 6T/A-T 3T/A-T 1T/A-T Heating current input Minimum line current 0.25 0.25 0.25 0.25 0.38 0.38 0.38 Maximum fuse current Sound pressure level...
  • Page 30: Compact 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.5 Compact 4-way Cassette Type GMV-ND22 GMV-ND28 GMV-ND36 GMV-ND45 GMV-ND50 GMV-ND56 Model T/B-T T/B-T T/B-T T/B-T T/B-T T/B-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input Heating power input...
  • Page 31: 360°Air Discharge Compact Cassette

    GREE Multi Variable Air Conditioners Indoor Units 3.6 360°Air Discharge Compact Cassette GMV-ND1 GMV-ND1 GMV-ND2 GMV-ND2 GMV-ND3 GMV-ND4 GMV-ND5 GMV-ND5 Model 5T/E-T 8T/E-T 2T/E-T 8T/E-T 6T/E-T 5T/E-T 0T/E-T 6T/E-T Cooling capacity Heating capacity 460/420 460/420 500/460 570/480 620/550 730/650 730/650...
  • Page 32 GREE Multi Variable Air Conditioners Indoor Units GMV-ND GMV-ND GMV-ND GMV-ND GMV-ND GMV-ND GMV-ND Model 28TS/A-T 36TS/A-T 45TS/A-T 50TS/A-T 56TS/A-T 63TS/A-T 71TS/A-T Heating power input Heating current input Minimum line current Maximum fuse current Sound pressure level dB(A) 35/32/29 35/32/29...
  • Page 33: 1-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.8 1-way Cassette Type GMV-ND22 GMV-ND28 GMV-ND36 GMV-ND45 GMV-ND50 GMV-ND56 Model TD/A-T TD/A-T TD/A-T TD/A-T TD/A-T TD/A-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input Heating power input...
  • Page 34: Floor Ceiling Type

    GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND63TD/B-T GMV-ND71TD/B-T GMV-ND80TD/B-T External Drain pipe diameter Φ25×2.5 Φ25×2.5 Φ25×2.5 ×thickness Main body W×D×H 1200×470×200 1200×470×200 1200×470×200 dimensions Panel W×D×H 1350×555×64 1350×555×64 1350×555×64 dimensions Main body Net weight Panel Notes: ① Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop between units.
  • Page 35 GREE Multi Variable Air Conditioners Indoor Units GMV-ND90 GMV-ND112 GMV-ND125 GMV-ND140 GMV-ND160 Model ZD/A-T ZD/A-T ZD/A-T ZD/A-T ZD/A-T Cooling capacity 11.2 12.5 14.0 16.0 Heating capacity 10.0 12.5 14.0 16.0 18.0 Air volume m³/h 1600 2000 2000 2000 2300 Cooling power input...
  • Page 36: Fresh Air Processing Unit

    GREE Multi Variable Air Conditioners Indoor Units GMV-ND28Z GMV-ND36Z GMV-ND50Z GMV-ND56Z GMV-ND63Z GMV-ND71Z Model D/B-T D/B-T D/B-T D/B-T D/B-T D/B-T External Drain pipe diameter × Φ17×1.75 Φ17×1.75 Φ17×1.75 Φ17×1.75 Φ17×1.75 Φ17×1.75 thickness Outline 870×665 870×665 870×665 870×665 1200×665 1200×665 W×D×H Dimensions ×235...
  • Page 37 GREE Multi Variable Air Conditioners Indoor Units GMV-NX140 GMV-NX224 GMV-NX280 GMV-NX280 GMV-NX450 Model P/A(X1.2)-K P/A(X2.0) -M P/A(X2.5) -M P/A(X3.0) -M P/A(X4.0) -M Cooling power input 1060 1240 Standard Static pressure (Pa) Optional Cooling current input 1.65 2.10 2.40 2.47 3.40...
  • Page 38 GREE Multi Variable Air Conditioners Indoor Units Model GMV-NDX250P/A-T GMV-NDX280P/A-T Cooling capacity 25.0 28.0 18.0 20.0 Heating capacity 20.0 22.0 Air volume m³/h 2500/2000~3500 2500/2000~3500 Standard Static pressure (Pa) Optional 50~300 50~300 Rated power input Rated current input Cooling power input...
  • Page 39: Slim Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 3.11 Slim Duct Type GMV-ND22 GMV-ND25 GMV-ND28 GMV-ND32 GMV-ND36 GMV-ND40 Model PL/B-T PL/B-T PL/B-T PL/B-T PL/B-T PL/B-T Cooling capacity Heating capacity Air volume m³/h Unit external static pressure 0/0~15 0/0~15 0/0~15 0/0~15 0/0~15...
  • Page 40 GREE Multi Variable Air Conditioners Indoor Units GMV-ND45PL GMV-ND50PL GMV-ND56PL GMV-ND63PL/ GMV-ND72PL Model /B-T /B-T /B-T /B-T External Drain pipe diameter × Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 thickness Dimensions W×D×H 1010×450×200 1010×450×200 1010×450×200 1010×450×200 1310×450×200 Net weight Main body 23.5 23.5...
  • Page 41: Air Handler Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Notes: ① Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop between units. ② Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6 °C WB; connection pipe length: 5 m, without height drop between units.
  • Page 42: Console Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.13 Console Type Indoor Unit GMV-ND22C/ GMV-ND28C/ GMV-ND36C/ GMV-ND45C/ GMV-ND50C/ Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.17 0.17 0.25 0.25 Heating power input Heating current input 0.17...
  • Page 43: Wall Mounted Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.14 Wall Mounted Type Indoor Unit GMV-N22G/A GMV-N28G/A GMV-N36G/A GMV-N45G/A GMV-N50G/A Model 3A-K 3A-K 3A-K 3A-K 3A-K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31...
  • Page 44 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/B GMV-N28G/B GMV-N36G/B GMV-N45G/B GMV-N50G/B Model 3A-K 3A-K 3A-K 3A-K 3A-K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 45 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A GMV-N28G/A GMV-N36G/A GMV-N45G/A GMV-N50G/A Model 2A-K 2A-K 2A-K 2A-K 2A-K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 46 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/ GMV-N28G/ GMV-N36G/ GMV-N45G/ GMV-N50G/ Model A4A-K A4A-K A4A-K A4A-K A4A-K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 47 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/ GMV-N28G/ GMV-N36G/ GMV-N45G/ GMV-N50G/ Model A8A-K A8A-K A8A-K A8A-K A8A-K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 48 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G GMV-N28G/ GMV-N36G/ GMV-N45G/ GMV-N50G/ Model /C9A-K C9A -K C9A-K C9A -K C9A -K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 49 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G GMV-N28G/ GMV-N36G/ GMV-N45G/ GMV-N50G/ Model /E3A-K E3A -K E3A -K E3A -K E3A -K Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31...
  • Page 50 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A3A GMV-N28G/A3A GMV-N36G/A3A GMV-N45G/A3A Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 51 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A2A GMV-N28G/A2A GMV-N36G/A2A GMV-N45G/A2A Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 52 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A4A- GMV-N28G/A4A- GMV-N36G/A4A- GMV-N45G/A4A- Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 53 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A8A GMV-N28G/A8A GMV-N36G/A8A GMV-N45G/A8A Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 54 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/C9A GMV-N28G/C9A GMV-N36G/C9A GMV-N45G/C9A Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 55 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/E3A- GMV-N28G/E3A- GMV-N36G/E3A- GMV-N45G/E3A- Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 56 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/B3A- GMV-N28G/B3A- GMV-N36G/B3A- GMV-N45G/B3A- Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.21 0.21 Heating power input Heating current input 0.21 0.21 *Minimum line current 0.25 0.25 0.38...
  • Page 57 GREE Multi Variable Air Conditioners Indoor Units GMV-ND50 GMV-ND56 GMV-ND22 GMV-ND28 GMV-ND36 GMV-ND45 Model G/A3A-T G/A3A-T G/A3A-T G/A3A-T G/A3A-T G/A3A-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.16 0.16 0.16 0.17 Heating power input Heating current input 0.16...
  • Page 58 GREE Multi Variable Air Conditioners Indoor Units GMV-ND2 GMV-ND2 GMV-ND3 GMV-ND4 GMV-ND5 GMV-ND5 Model 2G/A8A-T 8G/A8A-T 6G/A8A-T 5G/A8A-T 0G/A8A-T 6G/A8A-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.16 0.16 0.16 0.17 Heating power input Heating current input 0.16...
  • Page 59 GREE Multi Variable Air Conditioners Indoor Units GMV-ND1 GMV-ND18 GMV-ND22 GMV-ND28 GMV-ND36 GMV-ND45 Model 5G/B6B-T G/ B6B-T G/B6B-T G/B6B-T G/B6B-T G/B6B-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.12 0.17 Heating power input Heating current input 0.12...
  • Page 60 GREE Multi Variable Air Conditioners Indoor Units GMV-ND15 GMV-ND18 GMV-ND22 GMV-ND28 GMV-ND36 GMV-ND45 Model G/B4B-T G/B4B-T G/B4B-T G/B4B-T G/B4B-T G/B4B-T Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.12 0.17 Heating power input Heating current input 0.12...
  • Page 61 GREE Multi Variable Air Conditioners Indoor Units GMV-ND22G/C4 GMV-ND28G/C4 GMV-ND36G/C4 GMV-ND45G/C4 Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.12 0.17 Heating power input Heating current input 0.12 0.17 *Minimum line current 0.15 0.15...
  • Page 62 GREE Multi Variable Air Conditioners Indoor Units GMV-ND22G/C2 GMV-ND28G/C2 GMV-ND36G/C2 GMV-ND45G/C2 Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.12 0.17 Heating power input Heating current input 0.12 0.17 *Minimum line current 0.15 0.15...
  • Page 63 GREE Multi Variable Air Conditioners Indoor Units GMV-ND22G/D2 GMV-ND28G/D2 GMV-ND36G/D2 GMV-ND45G/D2 Model Cooling capacity Heating capacity Air volume m³/h Cooling power input Cooling current input 0.12 0.17 Heating power input Heating current input 0.12 0.17 *Minimum line current 0.15 0.15...
  • Page 64: Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.15 Super High Static Pressure Duct Type Indoor Unit GMV-ND22 GMV-ND25 GMV-ND28 GMV-ND32 GMV-ND36 GMV-ND40 Model PHS/B-T PHS/B-T PHS/B-T PHS/B-T PHS/B-T PHS/B-T Cooling capacity Heating capacity Air Volume m³/h External Static Pressure 60/0~150...
  • Page 65 GREE Multi Variable Air Conditioners Indoor Units GMV-ND45 GMV-ND50 GMV-ND56 GMV-ND63 GMV-ND71 GMV-ND80 Model PHS/B-T PHS/B-T PHS/B-T PHS/B-T PHS/B-T PHS/B-T Outline 700×700 700×700 1000×700 1000×700 1000×700 1000×700 W×D×H Dimensions ×300 ×300 ×300 ×300 ×300 ×300 Net weight GMV-ND90 GMV-ND10 GMV-ND11...
  • Page 66 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND400PH/AR-X GMV-ND450PH/AR-X GMV-N560PH/AR-M Cooling capacity 40.0 45.0 56.0 Heating capacity 45.0 50.0 63.0 Air Volume m³/h 8000 8200 10000 External Static Pressure 200/50~250 200/50~250 Cooling power input 2500 2550 2700 Cooling current input...
  • Page 67: Ahu-Kit Type

    GREE Multi Variable Air Conditioners Indoor Units 3.16 AHU-KIT Type Model GMV-N36U/A-T GMV-N71U/A-T GMV-N140U/A-T Capacity Defaulted capacity Cooling 14.0 of ex-factory Heating 16.0 Capacity Adjustable capacity Cooling 11.2 14.0 Heating 10.0 12.5 16.0 Power input Power Supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz AHU-KIT Φ6.35...
  • Page 68 GREE Multi Variable Air Conditioners Indoor Units Model GMV-N36U/B-T GMV-N71U/B-T GMV-N140U/B-T Capacity Defaulted capacity Cooling 14.0 of ex-factory Heating 16.0 Capacity Adjustable capacity Cooling 11.2 14.0 Heating 10.0 12.5 16.0 Power input Power Supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz AHU-KIT Φ6.35...
  • Page 69 GREE Multi Variable Air Conditioners Indoor Units Model GMV-N36U/C-T GMV-N71U/C-T GMV-N140U/C-T Capacity Defaulted capacity of ex- Cooling factory Heating Capacity Adjustable Cooling 11.2 capacity Heating 12.5 Power input Power Supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz AHU-KIT Φ6.35 Φ6.35 Φ9.52...
  • Page 70: Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units GMV-N560U/C-T GMV-N560U/C-T GMV-N560U/C-T Model(Combined) +GMV-N560U/C-T +GMV-N560U/C-T +GMV-N560U/C-T +GMV-N140U/C-T +GMV-N280U/C-T +GMV-N560U/C-T 840+840 840+840 Capacity 840+840+140 840+840+280 +560 +840 Cooling Heating 204.5 220.5 283.5 Power input 8+8+8 8+8+8 8+8+8 Power Supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz Liquid pipe Φ19.05...
  • Page 71: 360°Air Discharge Cassette

    GREE Multi Variable Air Conditioners Indoor Units 3.18 360°Air Discharge Cassette Model GMV-ND22T/C-T GMV-ND28T/C-T GMV-ND36T/C-T GMV-ND45T/C-T Cooling capacity Heating capacity ³ Air volume(H/M/L) 800/700/600 800/700/600 800/700/600 800/700/600 Cooling power input Cooling current input Heating power input Heating current input Minimum line current 0.50...
  • Page 72 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND50T/C-T GMV-ND56T/C-T GMV-ND63T/C-T GMV-ND71T/C-T Maximum fuse current Sound Pressure Level (H/M/L) dB(A) 35/32/29 37/33/30 37/34/31 37/34/31 Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz Liquid pipe Φ6.35 Φ9.52 Φ9.52 Φ9.52 Piping...
  • Page 73 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND125T/C-T GMV-ND140T/C-T GMV-ND160T/C-T Cooling capacity 12.5 Heating capacity ³ Air volume(H/M/L) 1650/1300/1100 1650/1300/1100 2000/1800/1430 Cooling power input Cooling current input Heating power input Heating current input Minimum line current 0.98 0.98 Maximum fuse current...
  • Page 74 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND50T/C1-T Cooling capacity Heating capacity ³ Air volume(H/M/L) 1000/800/700 Cooling power input Cooling current input 0.37 Heating power input Heating current input 0.37 Minimum line current 0.37 Maximum fuse current Sound Pressure Level (H/M/L)
  • Page 75 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND22T/D1-T GMV-ND28T/D1-T GMV-ND36T/D1-T GMV-ND45T/D1-T 40’ GP Loading Quantity 40’ HQ Model GMV-ND50T/D1-T GMV-ND56T/D1-T GMV-ND63T/D1-T GMV-ND71T/D1-T Cooling capacity Heating capacity ³ Air volume(H/M/L) 900/800/700 1100/935/850 1100/935/850 1100/935/850 Cooling power input Cooling current input 0.44...
  • Page 76 GREE Multi Variable Air Conditioners Indoor Units GMV-ND100T/D1- GMV-ND112T/D1- Model GMV-ND80T/D1-T GMV-ND90T/D1-T Panel W×D×H 950×950×65 950×950×65 950×950×65 950×950×65 dimensions Main body Net weight Panel Panel model TF06 TF06 TF06 TF06 40’ GP Loading Quantity 40’ HQ Model GMV-ND125T/D1-T GMV-ND140T/D1-T Cooling capacity 12.5...
  • Page 77: Heat Storage Module

    GREE Multi Variable Air Conditioners Indoor Units 3.19 Heat Storage Module Model XRZ180L/A-T power input current input 0.05 Maximum fuse current Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz Liquid pipe Φ6.35 Piping interface Gas pipe Φ12.7 Outline Dimensions (W×D×H) 730×450×220...
  • Page 78 GREE Multi Variable Air Conditioners Indoor Units GMV-ND45P GMV-ND50P GMV-ND56P GMV-ND63P GMV-ND71P GMV-ND80P Model HS/D-T HS/D-T HS/D-T HS/D-T HS/D-T HS/D-T External Drain pipe diameter × Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Thickness Outline 1000×700×30 1000×700×30 1000×700×30 1000×700×30 W×D×H mm 700×700×300 700×700×300...
  • Page 79: Control

    GREE Multi Variable Air Conditioners Indoor Units CONTROL...
  • Page 80: Operation Flowchart

    GREE Multi Variable Air Conditioners Indoor Units 1 Operation Flowchart...
  • Page 81: Wired Controller

    GREE Multi Variable Air Conditioners Indoor Units 2 Wired Controller 2.1 Control Panel Fig.2.1 Appearance of wired controller Fig.2.2 LED graphics of wired controller...
  • Page 82 GREE Multi Variable Air Conditioners Indoor Units Table 2.1 LED display instruction Symbols Instructions As for the outdoor unit with AI function, once AI function is turned on, AI icon is displayed. Up and down swing function. Current set fan speed (including auto, low speed, medium-low speed, medium speed, medium-high speed, high speedand turbo seven status).
  • Page 83 GREE Multi Variable Air Conditioners Indoor Units Symbols Instructions When inquiring or setting project number of indoor unit, it displays "NO." icon. Heating mode. Fan mode. Dry mode. Cooling mode. It shows the setting temperature value(In case the wired controller is controlling a Fresh Air Indoor Unit, then the temperature zone will display FAP).
  • Page 84: Installation And Removal

    GREE Multi Variable Air Conditioners Indoor Units Table 2.2 Function instruction of buttons Buttons Instructions ENTER/CANCEL Select and cancel function. Set operating temperature of indoor unit. Set Timer. Switch Quiet mode, Air grade, Clean grade, set upper and lower temperature limit under Save mode.
  • Page 85: Installation Method

    GREE Multi Variable Air Conditioners Indoor Units 2.2.2 Installation method Fig.2.5 Installation of Wired Controller Above is a simple installation method of wired controller. Please pay attention to the following: Before installation, please cut off the power for indoor unit.
  • Page 86 GREE Multi Variable Air Conditioners Indoor Units 2.2.4 Connection of communication cord There are 4 ways to connect wired controller with indoor units’ network: Fig.2.7 One wired controller controls Fig.2.8 Two wired controllers control one indoor unit one indoor unit Fig.2.9 One wired controller controls multiple indoor units simultaneously...
  • Page 87: Remote Controller

    GREE Multi Variable Air Conditioners Indoor Units 3 Remote Controller 3.1 Remote Controller YAP1F Button name and function introduction Button name Function ON/OFF Turn on or turn off the unit TURBO Set turbo function MODE Set operation mode Set up&down swing status...
  • Page 88: Panel Display

    GREE Multi Variable Air Conditioners Indoor Units 4 Panel Display 4.1 Control Panel Notes: “AIR” function is an optional function of indoor unit, for the unit without such function, this function is invalid; “E-HEATER”, “ROOM”, “OFFICE”, “RESTAURANT”, “COMMON” are obligate functions of indoor unit that cannot be set.
  • Page 89: Temperature Setting

    GREE Multi Variable Air Conditioners Indoor Units 4.2.4 Temperature Setting Press “▼” or “▲” buttons under power-on status, the set temperature will be increased or decreased at 1°C each time; when long press the buttons, the temperature will be increased or decreased at 1°C every 0.3 seconds.
  • Page 90 GREE Multi Variable Air Conditioners Indoor Units or “▼” button to set the time to be “00”, then the timer function is canceled; press “ON/OFF” button or without pressing any buttons for consecutive 5 seconds, it will quit the function setting status. After quitting the function setting status, the “...
  • Page 91: Speed Settings

    GREE Multi Variable Air Conditioners Indoor Units Turn on cooling energy-saving: with the unit is started up, under cooling or dry mode, press “Function” button to switch to energy-saving function, when “ ” icon flickers, press “▲”or “▼” button to adjust cooling temperature limit, after setting cooling temperature limit, press “ON/OFF”...
  • Page 92: Introduction To Unit Functions

    GREE Multi Variable Air Conditioners Indoor Units Setting of power-fail memory function Under power-off status, simultaneously press “Mode” button and “▲” button for 5 seconds to switch the memory method: if “88” LED displays “on”, it means it will memorize the on and off status of the unit after being de-energized (that is, after de-energizing and energizing the unit, the unit will resume to be the status before it is de-energized);...
  • Page 93: Engineering Application Functions Operated Through The Xk46 Wired Controller

    GREE Multi Variable Air Conditioners Indoor Units Function Name User parameter settings Engineering parameter query Engineering parameter settings Engineering application functions can be operated through the IDU wired controller (XK46 or XK79) or remote controller (fittings selectable). 5.1 Engineering Application Functions Operated through the XK46 Wired Controller 5.1.1 Master IDU Settings...
  • Page 94 GREE Multi Variable Air Conditioners Indoor Units Method 2: Step 1: Press and hold the “FUNCTION” button for five seconds in power-on or power-off status to enter the parameter query interface. Step 2: Press and hold the “FUNCTION” button for five seconds in “C00” status to enter the parameter setting interface.
  • Page 95 GREE Multi Variable Air Conditioners Indoor Units Project number query of IDUs in the entire communication network: Press and hold the “FUNCTION” button for five seconds in power-on or power-off status to enter the parameter query interface “C00”. Press “ ▽ ” to switch to “C18”. Press the “MODE” button to enter query. The timer area of each wired controller in the entire network displays the project number of the corresponding IDU.
  • Page 96 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Parameter Name View Method Code Range Operation method: In “C01” status, press the “MODE” button to enter project number query of IDU. Press “▲” or “▼” to switch the IDU SN.
  • Page 97 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Parameter Name View Method Code Range Operation method: In “C17” status, press the “MODE” button to enter the indoor relative humidity query interface. Press “▲” or “▼” to switch the IDU SN.
  • Page 98: User Parameter Settings

    GREE Multi Variable Air Conditioners Indoor Units 5.1.4 User Parameter Settings User parameters can be set in power-on or power-off status. Press and hold the “FUNCTION” button for five seconds. The temperature area displays “C00”. Press and hold the “FUNCTION” button for another five seconds to enter the wired controller parameter setting interface.
  • Page 99 GREE Multi Variable Air Conditioners Indoor Units Parameter Default Parameter Name Parameter Range Remark Code Value When power supply is insufficient, users are allowed to power on/off the IDU set with preferential Preferential 00: common operation operation and other IDUs are forcibly powered off. A...
  • Page 100 GREE Multi Variable Air Conditioners Indoor Units 5.1.5 Engineering Parameter Query Engineering parameters can be queried in power-on or power-off status. Press and hold the “FUNCTION” button for five seconds to enter the engineering parameter query interface. The temperature area displays “C00” and “View” is on.
  • Page 101 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Parameter View Method Code Name Range Operation method: In “C14” status, press the “MODE” button to enter inlet-tube temperature sensor query of IDU. Press “ ” or “ ” to switch the IDU SN.
  • Page 102 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Parameter View Method Code Name Range Operation method (n7 query is not supported for the slave wired controller): In “n7” status, the timer area is not displayed. Press the “MODE” button to enter parameter query of ODU.
  • Page 103 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Parameter View Method Code Name Range Operation method (nb query is not supported for the slave wired controller): In “nb” status, the timer area is not displayed. Press the “MODE” button to enter bar code query.
  • Page 104 GREE Multi Variable Air Conditioners Indoor Units 5.1.6 Engineering Parameter Settings Engineering parameters can be set in power-on or power-off status. Press and hold the “FUNCTION” button for five seconds. The temperature area displays “C00”. Continuously press the “MODE” button for three times, and then press and hold the “FUNCTION”...
  • Page 105 GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Name Parameter Range Default Value Remark Code Press “ ” or “ ” to add or reduce by 1°C. Corrected value Temperature The temperature sensor of unit and of environment sensor of unit:...
  • Page 106: Failure Display

    GREE Multi Variable Air Conditioners Indoor Units Parameter Parameter Name Parameter Range Default Value Remark Code 01: cancel the setting of dual heat source for the indoor unit 02: set the indoor unit as Flag bit for unit of dual heat source...
  • Page 107: Engineering Application Functions Operated Through The Xk79 Wired Controller

    GREE Multi Variable Air Conditioners Indoor Units Power-on High-pressure Protection Fault Interface Note: If the IDU connected with the current wired controller is a fresh-air IDU, “FAP” is displayed on the main interface of the wired controller. Only the outlet temperature can be set for the fresh-air IDU. For the setting method, see the “IDU Function Settings”...
  • Page 108 GREE Multi Variable Air Conditioners Indoor Units 5.2.1 Master IDU Settings The master IDU can be set through the wired controller or remote controller. The methods for setting the master IDU through the wired controller are as follows: Method 1: Step 1: Set an IDU to power-off status.
  • Page 109 GREE Multi Variable Air Conditioners Indoor Units Master IDU Display: ① For IDUs connected with wired controllers, “MASTER” on the wired controller connected with the master IDU will be on. ② For IDUs embedded or connected with LED panels, the operation LED on the LED panel of the master IDU will blink three times.
  • Page 110 GREE Multi Variable Air Conditioners Indoor Units 5.2.4 Engineering Parameter Query Engineering parameters can be queried in power-on or power-off status. Press and hold the “FUNCTION” button for five seconds to enter the engineering parameter query interface. The temperature area displays “C00” and “VIEW” is on.
  • Page 111: Engineering Application Functions Operated Through The Yap1F Remote Controller

    GREE Multi Variable Air Conditioners Indoor Units 5.3 Engineering Application Functions Operated through the YAP1F Remote Controller The YAP1F remote controller only provides engineering application functions for setting the master IDU. For other user operation functions, refer to the “Remote Controller Operating Instructions”.
  • Page 112 GREE Multi Variable Air Conditioners Indoor Units Button name Function Set timer on function Set left&right swing status Set fan speed Set temperature and time (For details about the above figures, refer to the instructions 66174100016). Perform settings by pressing “▲” and “▼” in air supply mode: ①...
  • Page 113: Installation

    GREE Multi Variable Air Conditioners Indoor Units INSTALLATION...
  • Page 114: Engineering Installation Preparation And Notice

    GREE Multi Variable Air Conditioners Indoor Units 1 Engineering Installation Preparation and Notice 1.1 Installation Notice Personnel and property safety are highly concerned during the entire installation process. Installation implementation must abide by relevant national safety regulations to ensure personnel and property safety.
  • Page 115: Installation Materials Selection

    GREE Multi Variable Air Conditioners Indoor Units Installation Problem Possible Consequence The refrigerant pipe or Water can easily condensate and drip to damage the indoor decoration, or even condensate water pipe does not trigger the protection mode of system due to overheating operation.
  • Page 116: Condensate Water Pipe

    GREE Multi Variable Air Conditioners Indoor Units 2.2 Condensate Water Pipe Pipes that can be used for air conditioner drainage include: water supplying UPVC pipe, PP-R pipe, PP-C pipe, and HDG steel pipe; All relevant certificates and quality test reports are provided.
  • Page 117: Power Cable

    Hanger rod: M8 or M10; U-steel: 14# or above; Angle steel: 30mm×30mm×3mm or above; Round steel: Φ10mm or above. 3 Installation of Indoor Unit 3.1 Installation of Floor Standing Indoor Unit 3.1.1 Outline and installation dimension Unit: mm Model GMV-ND100L/A-T 1870 GMV-ND140L/A-T...
  • Page 118: Installation Space

     Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 119: Installation Of High Static Pressure Duct Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.2 Installation of High Static Pressure Duct Type Unit 3.2.1 Outline and installation dimension Model: GMV-ND56PHS/A-T~ GMV-ND140PHS/A-T Below are dimensions of A, B, C, etc. for different models: Unit: mm Model GMV-ND56PHS/A-T GMV-ND63PHS/A-T...
  • Page 120 GREE Multi Variable Air Conditioners Indoor Units Model: GMV-ND224PH/A-T, GMV-ND280PH/A-T Below are dimensions of A, B, C, etc. for different models: Unit: mm Model GMV-ND224PH/A-T 1353 1150 GMV-ND280PH/A-T 1563 1350 3.2.2 Installation space GMV-ND56~140PHS/A-T Unit: mm GMV-ND160PHS/A-T Unit: mm...
  • Page 121  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 122 GREE Multi Variable Air Conditioners Indoor Units 3.2.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord /AWG) /AWG) 220-240V/50Hz GMV-ND56PHS/A-T 1.0/AWG18 1.0/AWG18...
  • Page 123: Installation Of Low Static Pressure Duct Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.3 Installation of Low Static Pressure Duct Type Unit 3.3.1 Outline and installation dimension Model: GMV-ND22PLS/A-T~GMV-ND63PLS/A-T Below are dimensions of A, B, C etc. for different models: Unit: mm Model GMV-ND22PLS/A-T GMV-ND25PLS/A-T GMV-ND28PLS/A-T...
  • Page 124 GREE Multi Variable Air Conditioners Indoor Units Model: GMV-ND71PLS/A-T~GMV-ND140PLS/A-T Unit: mm Below are dimensions of A, B, C etc. for different models: Unit: mm Model GMV-ND71PLS/A-T 1236 1200 1016 1050 GMV-ND80PLS/A-T GMV-ND90PLS/A-T GMV-ND100PLS/A-T GMV-ND112PLS/A-T 1379 1340 1153 1188 GMV-ND125PLS/A-T GMV-ND140PLS/A-T...
  • Page 125 GREE Multi Variable Air Conditioners Indoor Units The table below lists the detailed dimensions. Unit: mm Model GMV-ND18~36PLS/C-T GMV-ND40~63PLS/C-T 1060 1010 GMV-ND71PLS/C-T 1360 1310 Model: GMV-ND80PLS/C-T~GMV-ND140PLS/C-T Unit: mm The table below lists the detailed dimensions. Unit: mm Model GMV-ND80PLS/C-T 1236...
  • Page 126  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 127 GREE Multi Variable Air Conditioners Indoor Units  Do not connect power until all installation work is finished. 3.3.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire...
  • Page 128 GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord /AWG) /AWG) 220-240V/50Hz GMV-ND56PLS/C-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND63PLS/C-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND71PLS/C-T 1.0/AWG18...
  • Page 129: Installation Of 4-Way Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.4 Installation of 4-way Cassette Type Unit 3.4.1 Outline and installation dimension Unit: mm Model GMV-ND28~140T/A-T Unit: mm Model GMV-ND160T/A-T 1040...
  • Page 130  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 131: Installation Of Compact 4-Way Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord /AWG) /AWG) 220-240V/50Hz GMV-ND50T/A-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND56T/A-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND63T/A-T 1.0/AWG18...
  • Page 132  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 133: Installation Of 360°Air Discharge Compact Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.5.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND22T/B-T 1.0/AWG18 1.0/AWG18...
  • Page 134  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 135: Installation Of Compact 2-Way Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.6.4 Selection of air switch and power cord Minimum Sectional Area Minimum Sectional Area Air Switch Capacity Model Power Cord Size of Ground Wire of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND15T/E-T 1.0/AWG18 1.0/AWG18...
  • Page 136 GREE Multi Variable Air Conditioners Indoor Units Unit: mm Below are dimensions of A, B, C etc. for different models: Unit: mm Outer diameter of connection pipe Indoor Suspension Ceiling Decoration Model unit(A) bolt pitch(B) opening(C) panel(D) Liquid pipe Gas pipe...
  • Page 137  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 138: Installation Of Compact 1-Way Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Model Power Cord Size Air Switch Capacity(A) Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND28TS/B-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND36TS/B-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND45TS/B-T 1.0/AWG18...
  • Page 139  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 140: Installation Of Floor Ceiling Type Unit

    GREE Multi Variable Air Conditioners Indoor Units  Only qualified personnel can carry out installation work, please contact with local dealer before installation.  Make sure all the installation work completed before energizing. 3.8.4 Selection of air switch and power cord...
  • Page 141 GREE Multi Variable Air Conditioners Indoor Units Below are dimensions of A, B, C, etc. for different models: Unit: mm Outer diameter of Drainage pipe(Outer connection pipe Model Diameter × wall thickness) Liquid pipe Gas pipe GMV-ND28ZD/A-T 6.35 9.52 GMV-ND36ZD/A-T...
  • Page 142 GREE Multi Variable Air Conditioners Indoor Units 3.9.2 Installation space Unit: mm GMV-ND**ZD/A-T:  Floor type  Ceiling type GMV-ND**ZD/B-T:  Floor type...
  • Page 143  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 144 GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND140ZD/A-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz 220-240V/50Hz GMV-ND160ZD/A-T 1.0/AWG18 1.0/AWG18 208-230V/60Hz Minimum Sectional...
  • Page 145: Installation Of Fresh Air Processing Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.10 Installation of Fresh air Processing Unit 3.10.1 Outline and installation dimension GMV-NX140P/A(X1.2)-K Unit: mm GMV-NX224P/A(X2.0)-M; GMV-NX280P/A(X2.5)-M; GMV-NX280P/A(X3.0)-M Unit: mm...
  • Page 146 GREE Multi Variable Air Conditioners Indoor Units GMV-NX450P/A(X4.0)-M Unit: mm GMV-NDX125P/A-T、GMV-NDX140P/A-T The table below lists the detailed dimensions. Unit: mm Model GMV-NDX125P/A-T 1440 1530 1400 GMV-NDX140P/A-T 1440 1530 1400...
  • Page 147 GREE Multi Variable Air Conditioners Indoor Units GMV-NDX224P/A-T、GMV-NDX250P/A-T 、GMV-NDX280P/A-T The table below lists the detailed dimensions. Unit: mm Model GMV-NDX224P/A-T 1353 1150 GMV-NDX250P/A-T 1353 1150 GMV-NDX280P/A-T 1353 1150 3.10.2 Installation space Unit: mm Notes: ① Installation of the unit must be in accordance with National Electric Codes and local safety regulations.
  • Page 148: Installation Of Slim Duct Type Unit

     Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 149  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 150: Installation Of Air Handler Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V~50Hz/ GMV-ND40PL/B-T 1.0/AWG18 1.0/AWG18 208-230V~60Hz 220-240V~50Hz/ GMV-ND45PL/B-T 1.0/AWG18 1.0/AWG18 208-230V~60Hz 220-240V~50Hz/ GMV-ND50PL/B-T 1.0/AWG18...
  • Page 151: Installation Of Wall-Mounted Unit

    GREE Multi Variable Air Conditioners Indoor Units This air handler is designed for a complete supply and return ductwork system. Do not operate this product without all ductwork attached. Based upon the actual conditions, if air handler is installed as type (A), the air handler should be concealed in a specific room or space and make sure the air handler is not accessible to the general public.
  • Page 152 GREE Multi Variable Air Conditioners Indoor Units The table below lists the detailed dimensions. Unit: mm Model GMV-N22G/A3A-K, GMV-N28G/A3A-K, GMV-N22G/A2A-K, GMV-N28G/A2A-K, GMV-N22G/A4A-K, GMV-N28G/A4A-K, GMV-N22G/A8A-K, GMV-N28G/A8A-K, GMV-N22G/C9A-K, GMV-N28G/C9A-K, GMV-N22G/E3A-K, GMV-N28G/E3A-K, GMV-N22G/B3A-K, GMV-N28G/B3A-K, GMV-N22G/A3A-D, GMV-N28G/A3A-D, GMV-N22G/A2A-D, GMV-N28G/A2A-D, GMV-N22G/A4A-D, GMV-N28G/A4A-D, GMV-N22G/A8A-D, GMV-N28G/A8A-D, GMV-N22G/C9A-D, GMV-N28G/C9A-D,...
  • Page 153 GREE Multi Variable Air Conditioners Indoor Units 3.13.2 Installation space Unit: mm 3.13.3 Installation notice Connect the ends of the connection pipe with two leading pipes, and then tighten the joint nuts tightly. Connect the connect pipe with the two relative leading pipe, tie the nut on tie –in of the connect pipe tightly.
  • Page 154 GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) GMV-N45G/A3A-K GMV-N45G/A2A-K GMV-N45G/A4A-K GMV-N45G/A8A-K 220-240V ~ 50Hz 1.0/AWG18 1.0/AWG18 GMV-N45G/C9A-K GMV-N45G/E3A-K GMV-N45G/B3A-K...
  • Page 155 GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) GMV-N45G/A3A-D GMV-N45G/A2A-D GMV-N45G/A4A-D GMV-N45G/A8A-D 208~230V ~ 60Hz 1.0/AWG18 1.0/AWG18 GMV-N45G/C9A-D GMV-N45G/E3A-D GMV-N45G/B3A-D...
  • Page 156 GREE Multi Variable Air Conditioners Indoor Units Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) GMV-ND36G/A3A-T GMV-ND36G/A8A-T GMV-ND36G/B6B-T 220-240V~50Hz GMV-ND36G/B4B-T 1.0/AWG18 1.0/AWG18 /208-230V~60Hz GMV-ND36G/C4B-T GMV-ND36G/C2B-T GMV-ND36G/D2B-T GMV-ND45G/A3A-T...
  • Page 157: Console Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.14 Console Type Indoor Unit 3.14.1 Outline and installation dimension The table below lists the detailed dimensions. Unit: mm Model GMV-ND22C/A-T GMV-ND28C/A-T GMV-ND36C/A-T GMV-ND45C/A-T GMV-ND50C/A-T 3.14.2 Installation space Unit:mm 3.14.3 Installation notice Connect the ends of the connection pipe with two leading pipes, and then tighten the joint nuts tightly.
  • Page 158: Installation Of Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.15 Installation of Super High Static Pressure Duct Type Indoor Unit 3.15.1 Outline and installation dimension Model: GMV-ND22PHS/B-T~ GMV-ND180PHS/B-T Model:GMV-ND400PH/AR-X...
  • Page 159 GREE Multi Variable Air Conditioners Indoor Units Model: GMV-ND450PH/AR-X Model:GMV-N560PH/AR-M Below are dimensions of A, B, C, etc. for different models: Unit: mm Model GMV-ND22PHS/B-T GMV-ND25PHS/B-T GMV-ND28PHS/B-T GMV-ND32PHS/B-T GMV-ND36PHS/B-T GMV-ND40PHS/B-T GMV-ND45PHS/B-T GMV-ND50PHS/B-T GMV-ND56PHS/B-T GMV-ND63PHS/B-T 1040 1130 1000 GMV-ND71PHS/B-T GMV-ND80PHS/B-T GMV-ND90PHS/B-T...
  • Page 160 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND180PHS/B-T 1440 1580 1400 GMV-ND400PH/AR-X 1770 1730 1680 GMV-ND450PH/AR-X 2030 1179 1980 1040 1900 1100 GMV-N560PH/AR-M 2030 1309 1980 1040 1900 1100 3.15.2 Installation space Model: GMV-ND22PHS/B-T~ GMV-ND180PHS/B-T Unit: mm Model:GMV-ND400PH/AR-X Unit: mm...
  • Page 161  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 162 GREE Multi Variable Air Conditioners Indoor Units  Installation of the unit must be in accordance with National Electric Codes and local regulations.  Improper installation will affect unit’s performance, so do not install the unit by yourself. Please contact local dealer to arrange professional technicians for the installation.
  • Page 163: Installation Of Ahu-Kit Type

    GREE Multi Variable Air Conditioners Indoor Units 3.16 Installation of AHU-KIT Type 3.16.1 Outline and installation dimension Unit: mm Size of control box for GMV-N36U/A-T, GMV-N71U/A-T, GMV-N140U/A-T, GMV-N280U/A-T, GMV-N560U/A-T, GMV-N36U/B-T, GMV-N71U/B-T, GMV-N140U/B-T, GMV-N280U/B-T and GMV-N560U/B-T: Size of control box for GMV-N36U/C-T, GMV-N71U/C-T, GMV-N140U/C-T, GMV-N280U/C-T and GMV-N560U/C-T: 4×Φ9...
  • Page 164 GREE Multi Variable Air Conditioners Indoor Units Size of EXV box for GMV-N36U/A-T, GMV-N71U/A-T, GMV-N140U/A-T and GMV-N280U/A-T: Size of EXV box for GMV-N560U/A-T: Size of EXV box for GMV-N36U/B-T and GMV-N36U/C-T:...
  • Page 165 GREE Multi Variable Air Conditioners Indoor Units Size GMV-N71U/B-T, GMV-N140U/B-T, GMV-N280U/B-T, GMV-N71U/C-T,GMV-N140U/C-T and GMV-N280U/C-T: Size of EXV box for GMV-N560U/B-T and GMV-N560U/C-T: 4×Φ12 4×Φ6...
  • Page 166 GREE Multi Variable Air Conditioners Indoor Units 3.16.2 Installation space Unit: mm Maintenance space of control space : Maintenance space of EXV box:...
  • Page 167: Exv Installation

    GREE Multi Variable Air Conditioners Indoor Units 3.16.3 Installation notice  The EXV box can be installed inside and outside. The control box should be installed inside.  Do not install the EXV box in or on the outdoor unit.
  • Page 168: Brazing Work

    GREE Multi Variable Air Conditioners Indoor Units 3.16.4.2 Brazing Work Unit: mm Prepare the inlet/outlet field piping just in front of the connection (do not braze yet). 4×Ф6 4×Ф12 A: Inlet coming from the outdoor unit B: Outlet to air handling unit C: Wire clamp Remove the wire clamp (C) by unscrewing 6xM4.2.
  • Page 169: Piping Installation

    GREE Multi Variable Air Conditioners Indoor Units ④ Make sure that the other parts such as electrical box, tie wraps and wires are protected from direct brazing flames during brazing. ⑤ The EXV box is required to be installed in a vertical direction within the range of 90±15° (not allowed for horizontal work).Welding the connection tubes first before refrigerant pipes in order...
  • Page 170: Installation Of The Control Box

    GREE Multi Variable Air Conditioners Indoor Units L: The length of liquid pipe between the air handling unit to EXV box is no more than 2 m. L is to be considered as a part of the total maximum piping length. See installation manual of the outdoor unit for piping installation.
  • Page 171 GREE Multi Variable Air Conditioners Indoor Units Temprature Communication Controller Power cord sensor 、 cord cord cable Precautions: ① Temperature sensor cable and remote controller wire should be kept away from power cable in a distance of at least 50mm. Violating this rule may generate electric noise and lead to malfunctions.
  • Page 172: Installation Of The Temperature Sensors

    GREE Multi Variable Air Conditioners Indoor Units 3......Middle gear of fan 4......Low gear of fan D1/D2......Communication wires H1/H2......Wired controller Notes: ① The 2, 3, 4 of fan gear lines are shorted by the factory default. ② Neutral line of fan connects to the N (1).
  • Page 173 GREE Multi Variable Air Conditioners Indoor Units ① IN Temp. sensor (Liquid Temp. sensor) ② OUT Temp. sensor (Gas Temp. sensor) Installation of the temperature sensor cable: The length of temperature sensor wire is 10 m. Put the temperature sensor cable in an individual protective tube.
  • Page 174 GREE Multi Variable Air Conditioners Indoor Units Fix the temperature sensor with insulating aluminum tape in order to ensure good heat transference. Cover the temperature sensor with rubber belt to prevent looseness of temperature sensor. Use two wire ties to bind the temperature sensor securely.
  • Page 175: Installation Of The Exv Cable

    GREE Multi Variable Air Conditioners Indoor Units 3.16.7.3 Installation of Temperature Sensor When Several AHU-KITs are in Parallel Connection with One AHU When several AHU-KITs are in parallel connection with one AHU, all linkage AHU-KIT inlet pipes’ and outlet pipes’ temperature sensor must be installed at the position of corresponding pipeline of air handling unit.
  • Page 176 GREE Multi Variable Air Conditioners Indoor Units The quantity of expansion valve coil is determined by the actual number of fittings, The length of EXV Cable wire is 10 m (71,140,280,560 type) or 2.5 m (36 type). 3.16.9 Selection of air switch and power cord...
  • Page 177: Installation Of Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units 3.17 Installation of Concealed Floor Standing Type 3.17.1 Outline and installation dimension Below are dimensions of A, B, C, etc. for different models: Unit: mm Model GMV-ND22ZA/A-T GMV-ND28ZA/A-T 665.5 GMV-ND36ZA/A-T GMV-ND45ZA/A-T 865.5 1045...
  • Page 178  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 179: Installation Of 360°Air Discharge Cassette Type Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.17.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND22ZA/A-T 1.0/AWG18 1.0/AWG18...
  • Page 180 GREE Multi Variable Air Conditioners Indoor Units Outer Diameter of Drainage Pipe(Outer Connection Pipe(mm) Model Diameter× wall (mm) (mm) (mm) (mm) (mm) (mm) (mm) thickness) (mm) Liquid pipe Gas pipe GMV-ND22T/C-T 6.35 9.52 GMV-ND28T/C-T 6.35 9.52 GMV-ND36T/C-T 6.35 12.7 GMV-ND45T/C-T 6.35...
  • Page 181  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 182: Installation Of Heat Storage Module

    GREE Multi Variable Air Conditioners Indoor Units  Only qualified personnel can carry out installation work, please contact with local dealer before installation.  Make sure all the installation work completed before energizing. 3.18.4 Selection of air switch and power cord...
  • Page 183: Installation Of High Static Pressure Duct Type Indoor Unit

     Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 184  Please contact the local Gree appointed service center before installation. Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 185: Installation Of Drain Pipe

    GREE Multi Variable Air Conditioners Indoor Units 3.20.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Capacity Model Power Cord Size Area of Ground Wire Area of Power Cord (mm²/AWG) (mm²/AWG) 220-240V/50Hz GMV-ND22PHS/D-T 1.0/AWG18 1.0/AWG18...
  • Page 186: Installing The Drain Pipes

    GREE Multi Variable Air Conditioners Indoor Units For example: Keep pipe size equal to or greater than that of the connecting pipe. Install the drain piping as shown and take measures against condensation. Improperly rigged piping could lead to leaks and eventually wet furniture and belongings.
  • Page 187 GREE Multi Variable Air Conditioners Indoor Units  Insulate the pipe clamp and the drain hose using heat insulation sponge. Unit: mm  Install water trap as shown below.  Install one water trap for each unit.  Installation of water trap shall consider easy cleaning in the future.
  • Page 188: Precautions When Doing Riser Piping Work

    GREE Multi Variable Air Conditioners Indoor Units Unit: mm 4.3 Precautions When Doing Riser Piping Work  Make sure that heat insulation work is executed on the following 2 spots to prevent any possible water leakage due to dew condensation.
  • Page 189: Testing Of Drain Piping

    GREE Multi Variable Air Conditioners Indoor Units 4.4 Testing of Drain Piping  After piping work is finished, check if drainage flows smoothly.  Shown in the figure, Add approximately 1liter of water slowly into the drain pan and check drainage flow during COOL running.
  • Page 190: Maintenance

    GREE Multi Variable Air Conditioners Indoor Units MAINTENANCE...
  • Page 191: Troubleshooting

    GREE Multi Variable Air Conditioners Indoor Units 1 Troubleshooting 1.1 Malfunction List for the Wired Controller Error Error Error Content Content Content Code Code Code Quantity Of Group Control Indoor Unit Error Humidity Sensor Error Indoor Units Setting Error Indoor Units Incompatibility...
  • Page 192 GREE Multi Variable Air Conditioners Indoor Units 1.2.2 “d3” Ambient temperature sensor error Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge the range of AD value, If the sampling AD value exceeds upper limit and lower limit in 5 seconds continuously, report the error.
  • Page 193 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.4 “d6” Outlet pipe temperature sensor error Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge the range of AD value.
  • Page 194 GREE Multi Variable Air Conditioners Indoor Units 1.2.5 “d7” Humidity sensor error Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge the range of AD value.
  • Page 195 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.7 “dA” IDU network address error Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Through testing the IDU address chip and IP address, if address chip cannot be read, IDU IP is 0 or IP is in conflict, report the error.
  • Page 196 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.9 “dC” Capacity DIP switch setting error Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: If capacity DIP switch is set to the wrong position, report the error.
  • Page 197 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.11 “db” Project debugging Error display: ODU mainboard, IDU wired controller and IDU receive light board will display Error judgment condition and method: This is a status code of project debugging, not an error code. When IDU or ODU displays this code, it means the unit is under debugging status and the IDU cannot be operated.
  • Page 198 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.13 “L3” Water full protection Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Check the status of IDU float switch. When water level is too high, float switch is activated, so water full protection happens.
  • Page 199 GREE Multi Variable Air Conditioners Indoor Units ■Float switch operates abnormally ■IDU mainboard is abnormal Troubleshooting:...
  • Page 200 GREE Multi Variable Air Conditioners Indoor Units 1.2.14 “L4” Power supply overcurrent protection Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: Check if the power supply current from IDU to wired controller is normal. If power supply current is too big, it is judged that the current is abnormal.
  • Page 201 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.16 “L7” No master IDU Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: No master IDU error will happen when there is no master IDU in the system.
  • Page 202 GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: 1.2.17 “L9” Group-controlled IDU quantity inconsistency Error display: IDU wired controller and IDU receive light board will display Error judgment condition and method: If the IDU quantity connected with wired controller exceeds 16 sets or actually connected IDU quantity is inconsistent with the set group-controlled IDU quantity.
  • Page 203: After-Sales Emergency Measures

    GREE Multi Variable Air Conditioners Indoor Units Troubleshooting: Make sure the IDUs connected with one wired controller belong to the same series. 1.2.19 “LC” Mismatch of IDU and ODU models Error display: IDU wired controller and IDU receive light board will display...
  • Page 204: Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units 3.1 Floor Standing Type GMV-ND100L/A-T, GMV-ND140L/A-T: 3.2 High Static Pressure Duct Type GMV-ND56PHS/A-T, GMV-ND63PHS/A-T, GMV-ND71PHS/A-T, GMV-ND80PHS/A-T, GMV-ND90PHS/A-T, GMV-ND100PHS/A-T, GMV-ND112PHS/A-T, GMV-ND125PHS/A-T, GMV-ND140PHS/A-T:...
  • Page 205 GREE Multi Variable Air Conditioners Indoor Units GMV-ND160PHS/A-T: GMV-ND224PH/A-T, GMV-ND280PH/A-T:...
  • Page 206: Low Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 3.3 Low Static Pressure Duct Type GMV-ND22PLS/A-T, GMV-ND25PLS/A-T, GMV-ND28PLS/A-T, GMV-ND32PLS/A-T, GMV-ND36PLS/A-T, GMV-ND40PLS/A-T, GMV-ND45PLS/A-T, GMV-ND50PLS/A-T, GMV-ND56PLS/A-T, GMV-ND63PLS/A-T, GMV-ND71PLS/A-T, GMV-ND80PLS/A-T: GMV-ND90PLS/A-T, GMV-ND100PLS/A-T, GMV-ND112PLS/A-T, GMV-ND125PLS/A-T, GMV-ND140PLS/A-T:...
  • Page 207 GREE Multi Variable Air Conditioners Indoor Units GMV-ND18PLS/C-T, GMV-ND22PLS/C-T, GMV-ND25PLS/C-T, GMV-ND28PLS/C-T, GMV-ND32PLS/C-T, GMV-ND36PLS/C-T, GMV-ND40PLS/C-T, GMV-ND45PLS/C-T, GMV-ND50PLS/C-T, GMV-ND56PLS/C-T, GMV-ND63PLS/C-T, GMV-ND71PLS/C-T: GMV-ND80PLS/C-T:...
  • Page 208 GREE Multi Variable Air Conditioners Indoor Units GMV-ND90PLS/C-T, GMV-ND100PLS/C-T, GMV-ND112PLS/C-T, GMV-ND125PLS/C-T, GMV-ND140PLS/C-T:...
  • Page 209 GREE Multi Variable Air Conditioners Indoor Units GMV-ND18PLS/C1-T, GMV-ND22PLS/C1-T, GMV-ND25PLS/C1-T, GMV-ND28PLS/C1-T, GMV-ND32PLS/C1-T, GMV-ND36PLS/C1-T, GMV-ND40PLS/C1-T, GMV-ND45PLS/C1-T, GMV-ND50PLS/C1-T, GMV-ND56PLS/C1-T, GMV-ND63PLS/C1-T, GMV-ND71PLS/C1-T, GMV-ND80PLS/C1-T:...
  • Page 210: 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.4 4-way Cassette Type GMV-ND28T/A-T, GMV-ND36T/A-T, GMV-ND45T/A-T, GMV-ND50T/A-T, GMV-ND56T/A-T, GMV-ND63T/A-T, GMV-ND71T/A-T, GMV-ND80T/A-T: GMV-ND90T/A-T, GMV-ND100T/A-T, GMV-ND112T/A-T, GMV-ND125T/A-T, GMV-ND140T/A-T:...
  • Page 211: Compact 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units GMV-ND160T/A-T: 3.5 Compact 4-way Cassette Type GMV-ND22T/B-T, GMV-ND28T/B-T, GMV-ND36T/B-T, GMV-ND45T/B-T, GMV-ND50T/B-T, GMV-ND56T/B-T:...
  • Page 212: 360°Air Discharge Compact Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.6 360°Air Discharge Compact Cassette Type GMV-ND15T/E-T,GMV-ND18T/E-T,GMV-ND22T/E-T,GMV-ND28T/E-T,GMV-ND36T/E-T, GMV-ND45T/E-T, GMV-ND50T/E-T, GMV-ND56T/E-T...
  • Page 213: 2-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.7 2-way Cassette Type GMV-ND28TS/A-T, GMV-ND36TS/A-T, GMV-ND45TS/A-T, GMV-ND50TS/A-T, GMV-ND56TS/A-T, GMV-ND63TS/A-T, GMV-ND71TS/A-T: GMV-ND28TS/B-T, GMV-ND36TS/B-T, GMV-ND45TS/B-T, GMV-ND50TS/B-T, GMV-ND56TS/B-T, GMV-ND63TS/B-T, GMV-ND71TS/B-T, GMV-ND80TS/B-T:...
  • Page 214: 1-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.8 1-way Cassette Type GMV-ND22TD/A-T, GMV-ND28TD/A-T, GMV-ND36TD/A-T, GMV-ND45TD/A-T, GMV-ND50TD/A-T, GMV-ND56TD/A-T: GMV-ND63TD/B-T, GMV-ND71TD/B-T, GMV-ND80TD/B-T:...
  • Page 215: Floor Ceiling Type

    GREE Multi Variable Air Conditioners Indoor Units 3.9 Floor Ceiling Type GMV-ND28ZD/A-T, GMV-ND36ZD/A-T, GMV-ND50ZD/A-T, GMV-ND56ZD/A-T, GMV-ND63ZD/A-T, GMV-ND71ZD/A-T, GMV-ND90ZD/A-T, GMV-ND112ZD/A-T, GMV-ND125ZD/A-T, GMV-ND140ZD/A-T, GMV-ND160ZD/A-T:...
  • Page 216 GREE Multi Variable Air Conditioners Indoor Units GMV-ND28ZD/B-T, GMV-ND36ZD/B-T, GMV-ND50ZD/B-T, GMV-ND56ZD/B-T, GMV-ND112ZD/B-T, GMV-ND125ZD/B-T, GMV-ND140ZD/B-T, GMV-ND160ZD/B-T:...
  • Page 217: Fresh Air Processing Unit

    GREE Multi Variable Air Conditioners Indoor Units GMV-ND63ZD/B-T, GMV-ND71ZD/B-T, GMV-ND90ZD/B-T: 3.10 Fresh air Processing Unit GMV-NX140P/A(X1.2)-K:...
  • Page 218 GREE Multi Variable Air Conditioners Indoor Units GMV-NX224P/A(X2.0)-M, GMV-NX280P/A(X2.5)-M, GMV-NX280P/A(X3.0)-M: GMV-NX450P/A(X4.0)-M:...
  • Page 219 GREE Multi Variable Air Conditioners Indoor Units GMV-NDX125P/A-T, GMV-NDX140P/A-T: GMV-NDX224P/A-T, GMV-NDX250P/A-T, GMV-NDX280P/A-T:...
  • Page 220: Slim Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 3.11 Slim Duct Type GMV-ND22PL/B-T, GMV-ND25PL/B-T, GMV-ND28PL/B-T, GMV-ND32PL/B-T, GMV-ND36PL/B-T, GMV-ND40PL/B-T, GMV-ND45PL/B-T, GMV-ND50PL/B-T, GMV-ND56PL/B-T, GMV-ND63PL/B-T, GMV-ND72PL/B-T, GMV-ND22PLS/B1-T, GMV-ND25PLS/B1-T, GMV-ND28PLS/B1-T, GMV-ND32PLS/B1-T, GMV-ND36PLS/B1-T, GMV-ND40PLS/B1-T, GMV-ND45PLS/B1-T, GMV-ND50PLS/B1-T, GMV-ND56PLS/B1-T, GMV-ND63PLS/B1-T, GMV-ND71PLS/B1-T:...
  • Page 221: Air Handler Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.12 Air Handler Type Indoor Unit GMV-NR71A/A-D, GMV-NR90A/A-D, GMV-NR100A/A-D, GMV-NR112A/A-D, GMV-NR140A/A-D:...
  • Page 222: Console Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.13 Console Type Indoor Unit GMV-ND22C/A-T, GMV-ND28C/A-T, GMV-ND36C/A-T, GMV-ND45C/A-T, GMV-ND50C/A-T: 3.14 Wall Mounted type Indoor Unit GMV-N22G/A3A-K、 GMV-N28G/A3A-K、GMV-N36G/A3A-K、GMV-N45G/A3A-K、 GMV-N50G/A3A-K、GMV-N56G/A3A-K、GMV-N63G/A3A-K、GMV-N71G/A3A-K; GMV-N22G/B3A-K、 GMV-N28G/B3A-K、GMV-N36G/B3A-K、GMV-N45G/B3A-K、 GMV-N50G/B3A-K、GMV-N56G/B3A-K、GMV-N63G/B3A-K、GMV-N71G/B3A-K; GMV-N22G/A2A-K、 GMV-N28G/A2A-K、GMV-N36G/A2A-K、GMV-N45G/A2A-K、 GMV-N50G/A2A-K、GMV-N56G/A2A-K、GMV-N63G/A2A-K、GMV-N71G/A2A-K; GMV-N22G/A4A-K、 GMV-N28G/A4A-K、GMV-N36G/A4A-K、GMV-N45G/A4A-K、 GMV-N50G/A4A-K、GMV-N56G/A4A-K、GMV-N63G/A4A-K、GMV-N71G/A4A-K; GMV-N22G/A8A-K、 GMV-N28G/A8A-K、GMV-N36G/A8A-K、GMV-N45G/A8A-K、 GMV-N50G/A8A-K、GMV-N56G/A8A-K、GMV-N63G/A8A-K、GMV-N71G/A8A-K; GMV-N22G/C9A-K、GMV-N28G/C9A-K、 GMV-N36G/C9A-K、GMV-N45G/C9A-K、...
  • Page 223 GREE Multi Variable Air Conditioners Indoor Units GMV-N22G/A2A-D、GMV-N28G/A2A-D、GMV-N36G/A2A-D、GMV-N45G/A2A-D、 GMV-N50G/A2A-D、GMV-N56G/A2A-D、GMV-N63G/A2A-D、GMV-N71G/A2A-D; GMV-N22G/A4A-D、GMV-N28G/A4A-D、GMV-N36G/A4A-D、GMV-N45G/A4A-D、 GMV-N50G/A4A-D、GMV-N56G/A4A-D、GMV-N63G/A4A-D、GMV-N71G/A4A-D; GMV-N22G/A8A-D、GMV-N28G/A8A-D、GMV-N36G/A8A-D、GMV-N45G/A8A-D、 GMV-N50G/A8A-D、GMV-N56G/A8A-D、GMV-N63G/A8A-D、GMV-N71G/A8A-D; GMV-N22G/C9A-D、 GMV-N28G/C9A-D、GMV-N36G/C9A-D、GMV-N45G/C9A-D、 GMV-N50G/C9A-D、GMV-N56G/C9A-D、GMV-N63G/C9A-D、GMV-N71G/ C9A-D; GMV-N22G/E3A-D、 GMV-N28G/E3A-D、 GMV-N36G/E3A-D、GMV-N45G/E3A-D、 GMV-N50G/E3A-D、GMV-N56G/E3A-D、GMV-N63G/E3A-D、GMV-N71G/ E3A-D; GMV-N22G/B3A-D、GMV-N28G/B3A-D、GMV-N36G/B3A-D、GMV-N45G/B3A-D、 GMV-N50G/B3A-D、GMV-N56G/B3A-D、GMV-N63G/B3A-D、GMV-N71G/B3A-D;...
  • Page 224 GREE Multi Variable Air Conditioners Indoor Units GMV-ND22G/A3A-T、GMV-ND28G/A3A-T、GMV-ND36G/A3A-T GMV-ND22G/A8A-T、GMV-ND28G/A8A-T、GMV-ND36G/A8A-T GMV-ND45G/A3A-T 、 GMV-ND50G/A3A-T 、 GMV-ND56G/A3A-T 、 GMV-ND63G/A3A-T 、 GMV-ND71G/A3A-T 、 GMV-ND45G/A8A-T 、 GMV-ND50G/A8A-T 、 GMV-ND56G/A8A-T 、 GMV-ND63G/A8A-T、GMV-ND71G/A8A-T...
  • Page 225 GREE Multi Variable Air Conditioners Indoor Units GMV-ND80G/A3A-T、GMV-ND90G/A3A-T、GMV-ND100G/A3A-T GMV-ND80G/A8A-T、GMV-ND90G/A8A-T、GMV-ND100G/A8A-T GMV-ND80G/B4B-T、GMV-ND90G/B4B-T、GMV-ND100G/B4B-T...
  • Page 226 GREE Multi Variable Air Conditioners Indoor Units GMV-ND15G/B6B-T、GMV-ND18G/B6B-T、GMV-ND22G/B6B-T、GMV-ND28G/B6B-T、 GMV-ND36G/B6B-T、GMV-ND45G/B6B-T、GMV-ND50G/B6B-T、GMV-ND56G/B6B-T、 GMV-ND63G/B6B-T、GMV-ND71G/B6B-T GMV-ND15G/B4B-T、GMV-ND18G/B4B-T、GMV-ND22G/B4B-T、GMV-ND28G/B4B-T、 GMV-ND36G/B4B-T、GMV-ND45G/B4B-T、GMV-ND50G/B4B-T、GMV-ND56G/B4B-T、 GMV-ND63G/B4B-T、GMV-ND71G/B4B-T GMV-ND22G/C4B-T、GMV-ND28G/C4B-T、GMV-ND36G/C4B-T、GMV-ND45G/C4B-T、 GMV-ND50G/C4B-T、GMV-ND56G/C4B-T、GMV-ND63G/C4B-T、GMV-ND71G/C4B-T GMV-ND22G/C2B-T、GMV-ND28G/C2B-T、GMV-ND36G/C2B-T、GMV-ND45G/C2B-T、 GMV-ND50G/C2B-T、GMV-ND56G/C2B-T、GMV-ND63G/C2B-T、GMV-ND71G/C2B-T GMV-ND22G/D2B-T、GMV-ND28G/D2B-T、GMV-ND36G/D2B-T、GMV-ND45G/D2B-T、 GMV-ND50G/D2B-T、GMV-ND56G/D2B-T、GMV-ND63G/D2B-T、GMV-ND71G/D2B-T...
  • Page 227: Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 3.15 Super High Static Pressure Duct Type Indoor Unit GMV-ND22PHS/B-T, GMV-ND25PHS/B-T, GMV-ND28PHS/B-T, GMV-ND32PHS/B-T, GMV-ND36PHS/B-T, GMV-ND40PHS/B-T, GMV-ND45PHS/B-T, GMV-ND50PHS/B-T, GMV-ND56PHS/B-T, GMV-ND63PHS/B-T, GMV-ND71PHS/B-T, GMV-ND80PHS/B-T:...
  • Page 228 GREE Multi Variable Air Conditioners Indoor Units GMV-ND90PHS/B-T, GMV-ND100PHS/B-T, GMV-ND112PHS/B-T, GMV-ND125PHS/B-T: GMV-ND140PHS/B-T, GMV-ND160PHS/B-T:...
  • Page 229 GREE Multi Variable Air Conditioners Indoor Units GMV-ND180PHS/B-T: GMV-ND400PH/AR-X、GMV-ND450PH/AR-X、GMV-N560PH/AR-M...
  • Page 230: Ahu-Kit Type

    GREE Multi Variable Air Conditioners Indoor Units 3.16 AHU-KIT Type GMV-N36U/A-T, GMV-N71U/A-T, GMV-N140U/A-T, GMV-N280U/A-T, GMV-N560U/A-T:...
  • Page 231 GREE Multi Variable Air Conditioners Indoor Units GMV-N36U/B-T, GMV-N71U/B-T, GMV-N140U/B-T, GMV-N280U/B-T, GMV-N560U/B-T, GMV-N36U/C-T, GMV-N71U/C-T, GMV-N140U/C-T, GMV-N280U/C-T, GMV-N560U/C-T:...
  • Page 232: Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units 3.17 Concealed Floor Standing Type GMV-ND22ZA/A-T, GMV-ND28ZA/A-T, GMV-ND36ZA/A-T, GMV-ND45ZA/A-T, GMV-ND56ZA/A-T、 GMV-ND63ZA/A-T, GMV-ND71ZA/A-T:...
  • Page 233: 360°Air Discharge Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 3.18 360°Air Discharge Cassette Type GMV-ND22T/C-T,GMV-ND28T/C-T,GMV-ND36T/C-T,GMV-ND45T/C-T,GMV-ND50T/C-T, GMV-ND56T/C-T,GMV-ND63T/C-T,GMV-ND71T/C-T,GMV-ND80T/C-T,GMV-ND90T/C-, GMV-ND100T/C-T,GMV-ND112T/C-T,GMV-ND125T/C-T,GMV-ND140T/C-T,...
  • Page 234 GREE Multi Variable Air Conditioners Indoor Units GMV-ND160T/C-T GMV-ND22T/C1-T,GMV-ND28T/C1-T,GMV-ND36T/C1-T,GMV-ND45T/C1-T,GMV-ND50T/C1-T:...
  • Page 235 GREE Multi Variable Air Conditioners Indoor Units GMV-ND22T/D1-T,GMV-ND28T/D1-T,GMV-ND36T/D1-T,GMV-ND45T/D1-T,GMV-ND50T/D1-T,GM V-ND56T/D1-T,GMV-ND63T/D1-T,GMV-ND71T/D1-T: GMV-ND80T/D1-T,GMV-ND90T/D1-T,GMV-ND100T/D1-T,GMV-ND112T/D1-T,GMV-ND125T/D1-T, GMV-ND140T/D1-T:...
  • Page 236: Heat Storage Module

    GREE Multi Variable Air Conditioners Indoor Units 3.19 Heat Storage Module XRZ180L/A-T 3.20 High Static Pressure Duct Type Indoor Unit GMV-ND22PHS/D-T,GMV-ND25PHS/D-T,GMV-ND28PHS/D-T,GMV-ND32PHS/D-T,GMV-ND36PH S/D-T,GMV-ND40PHS/D-T,GMV-ND45PHS/D-T,GMV-ND50PHS/D-T,GMV-ND56PHS/D-T,GMV-ND63 PHS/D-T, GMV-ND71PHS/D-T, GMV-ND80PHS/D-T:...
  • Page 237 GREE Multi Variable Air Conditioners Indoor Units GMV-ND90PHS/D-T, GMV-ND100PHS/D-T, GMV-ND112PHS/D-T, GMV-ND125PHS/D-T, GMV-ND140PHS/D-T, GMV-ND160PHS/D-T: GMV-ND180PHS/D-T:...
  • Page 238: Disassembly And Assembly Procedure Of Main Parts

    GREE Multi Variable Air Conditioners Indoor Units 4 Disassembly and Assembly Procedure Of Main Parts 4.1 Floor Standing Type Removal and Assembly of electric box Remarks: Before removing the electric box, make sure to cut off the power firstly. Step...
  • Page 239: High Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 4.2 High Static Pressure Duct Type Note: The following steps are specific for GMV-ND71PHS/A-T units. For other units, the assembly and disassembly procedure is similar except the specifications of centrifugal fans and motors.
  • Page 240: Low Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the centrifugal fan. ●Loosen the fasteners of the motor 5. Remove the motor and and remove the motor from the centrifugal fan.
  • Page 241 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew 5. Remove the front volute the front volute casing and then casing. remove the volute casing.
  • Page 242 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ● Loosen the fasteners that connect 3. Remove the rear volute the rear volute casing with the front casing.
  • Page 243: 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Remove the filter from the air 2. Remove the filter. return frame. 3. Remove the air return ●Use a screwdriver to unscrew cover plate.
  • Page 244 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure 2. Remove the water tray. ●Remove the water tray. 3. Unscrew the centrifugal ●Use a wrench to unscrew the fan. centrifugal fan. 4. Remove the centrifugal ●Remove the centrifugal fan.
  • Page 245 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure 9. Install and screw the water ●Use a screwdriver to screw the tray. water tray Pump Step Diagram Operation Procedure Loosen the screws ●Use a screwdriver to unscrew the 1.
  • Page 246: Compact 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 4.5 Compact 4-way Cassette Type Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to unscrew the 1. Unscrew the water tray. water tray. 2. Remove the water tray. ●Remove the water tray.
  • Page 247 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to screw the 7. Screw the motor. motor. ●Install the centrifugal fan and use 8. Install and screw the a wrench to screw the centrifugal centrifugal fan.
  • Page 248 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure ●Remove the drainage duct and 3. Remove the drainage duct use a screwdriver to unscrew the and unscrew the pump. pump. 4. Replace the pump. ●Replace the pump.
  • Page 249: 360°Air Discharge Compact Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 4.6 360°Air Discharge Compact Cassette Type Motor and fan Step Diagram Operation Procedure ●Turn off the power supply of indoor unit. ●Push the 4 corner plates in the 1. Remove the front panel.
  • Page 250 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to remove the 4. Remove the fan. clamping band of motor. Then remove the fan. ●Use a screwdriver to unscrew the 5. Remove motor.
  • Page 251: 2-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure ●Direct the 4 corners of water tray to the 4 corners of the unit and then press them. screwdriver to tighten the screws in the 4 corners.
  • Page 252 GREE Multi Variable Air Conditioners Indoor Units Removal of Fan Motor Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Assemble units based on the 5. Replace the motor with a reverse order of this procedure and new one.
  • Page 253: 1-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units Removal of Fan Motor Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ● The wrench loosens the fixing motor nut 4. Remove motor. ● Cut off the fasteners that fixed the motor wire ●...
  • Page 254 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure 4. Remove the volute tongue. ●Remove the volute tongue. ●Use a screwdriver to unscrew the 5. Unscrew the outlet board. outlet board and then remove the board.
  • Page 255 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure 10. Install the evaporator. ●Install the evaporator. ●Use a screwdriver to screw the 11. Screw the outlet board. outlet board. 12. Put the volute tongue ●Put the volute tongue back to back to position.
  • Page 256 GREE Multi Variable Air Conditioners Indoor Units GMV-ND**TD/B-T: Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure 1. Remove the air return ● Press out all the grille tabs and grille. then remove the grille.
  • Page 257: Floor Ceiling Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Assemble units based on the 9. Install a new motor. reverse order of this procedure and power on the units for test.
  • Page 258 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Loosen the fasteners that connect 6. Remove the rear volute the rear volute casing with the front casing. volute casing and remove the rear volute casing.
  • Page 259 GREE Multi Variable Air Conditioners Indoor Units 4.9.2 GMV-ND**ZD/B-T Note: The following steps are specific for GMV-ND140ZD/B-T units. For other units, the assembly and disassembly procedure is similar except the numbers of centrifugal fans and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 260 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the 5. Remove the rear rear connecting board and them connecting board. remove the board.
  • Page 261: Fresh Air Processing Unit

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Assemble units based on the 10. Install a new motor. reverse order of this procedure and power on the units for test.
  • Page 262 GREE Multi Variable Air Conditioners Indoor Units GMV-NX224P/A(X2.0)-M, GMV-NX280P/A(X2.5)-M, GMV-NX280P/A(X3.0)-M: Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the electric box cover. 1.Remove the line ●Remove from the master board connecting to the motor.
  • Page 263 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the 2. Remove the cover plate bolt to fixture the cover plate assembly ●Remove the motor from the support and remove the centrifugal fan from the motor axle.
  • Page 264 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Assemble units based on the 5. Install a new motor. reverse order of this procedure and power on the units for test.
  • Page 265: Slim Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 4.11 Slim Duct Type Note: The following steps are specific for GMV-ND22PL/B-T units. For other units, the assembly and disassembly procedure is similar except the numbers of louvers and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 266 GREE Multi Variable Air Conditioners Indoor Units Note: The following steps are specific for GMV-ND22PLS/C-T units. For other units, the assembly and disassembly procedure is similar except the numbers of louvers and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 267: Console Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Assemble units based on the 7. Install units in a reverse order reverse order of this procedure and of this procedure.
  • Page 268: Wall Mounted Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Removal of Fan Motor Remark: before removing, making sure power is disconnected. Step Diagram Operation Procedure ●Remove the fixer fixing the 5. Remove evaporator evaporator, press 2 clasps at left side and then remove the evaporator.
  • Page 269 GREE Multi Variable Air Conditioners Indoor Units Removal of Fan Motor Remark: before removing, making sure power is disconnected. Step Diagram Operation Procedure ●Unscrew the screws fixing the 4. Remove the front panel front panel assembly. assembly ●Remove the front panel assembly.
  • Page 270: Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units Removal of Fan Motor Remark: before removing, making sure power is disconnected. Step Diagram Operation Procedure ●Take off the motor and fan directly. 10. Remove the motor and ●Use a screwdriver to unscrew the screws connecting the motor and the fan.
  • Page 271 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the 4. Remove the centrifugal front volute casing and then remove fan. the volute casing.
  • Page 272: Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the front 3. Remove the volute casing and then remove the centrifugal fan. volute casing.
  • Page 273 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Remove the filter from the air 2. Remove the filter. return frame. 3. Remove the air return ●Use a screwdriver to unscrew the cover plate.
  • Page 274: 360°Air Discharge Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Remove the motor from the support and remove the centrifugal fan from the motor axle. Then, 7. Remove the motor.
  • Page 275 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure 2. Remove the cover of ●Remove the motor wire and electric box and the clamp of water pump of the electric box. power cord. ●Loosen the screws in the 4 3.
  • Page 276 GREE Multi Variable Air Conditioners Indoor Units Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to unscrew the 5. Remove motor. 4 screws of motor. Then remove the motor. ●Remove the motor from motor support and then replace with a 6.
  • Page 277: High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 4.17 High Static Pressure Duct Type Indoor Unit Note: The following steps are specific for GMV-ND80PHS/D-T units. For other units, the assembly and disassembly procedure is similar except the specifications of centrifugal fans and motors.
  • Page 278: Exploded Views And Part List

    Diagram Operation Procedure ●Assemble units based on the 6. Install a new motor. reverse order of this procedure and power on the units for test. 5 Exploded Views and Part List 5.1 Floor Standing Type Exploded View of GMV-ND100L/A-T, GMV-ND140L/A-T:...
  • Page 279 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND100L/A-T GMV-ND140L/A-T Product Code CM300N0060 CM300N0070 Part Name Part Code Part Code Air Outlet Panel Assy 20004505 20004505 Swing Lever 10584218 10584218 Stepping Motor 15214005 15214005 Guide blade Lever 10584089 10584089 Stepping Motor...
  • Page 280: High Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 5.2 High Static Pressure Duct Type Exploded View of GMV-ND56PHS/A-T, GMV-ND63PHS/A-T, GMV-ND71PHS/A-T, GMV-ND80PHS/A-T: 16 17 For the following unit Unit Product Code GMV-ND56PHS/A-T CM800N3690 Name of part GMV-ND63PHS/A-T CM800N3700 GMV-ND71PHS/A-T CM800N3540 GMV-ND80PHS/A-T CM800N3710...
  • Page 281 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56PHS/A-T CM800N3690 Name of part GMV-ND63PHS/A-T CM800N3700 GMV-ND71PHS/A-T CM800N3540 GMV-ND80PHS/A-T CM800N3710 Part code Quantity Electric Box Assy 01394100255 Main Board 30226000027 Terminal Board 42000100000101 Terminal Board...
  • Page 282 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND90PHS/A-T, GMV-ND100PHS/A-T, GMV-ND112PHS/A-T, GMV-ND125PHS/A-T, GMV-ND140PHS/A-T: For the following unit Unit Product Code GMV-ND90PHS/A-T CM800N3550 GMV-ND100PHS/A-T CM800N3650 Name of part GMV-ND112PHS/A-T CM800N3660 GMV-ND125PHS/A-T CM800N3670 GMV-ND140PHS/A-T CM800N3680 Part code Quantity Filter Sub-Assy...
  • Page 283 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND90PHS/A-T CM800N3550 GMV-ND100PHS/A-T CM800N3650 Name of part GMV-ND112PHS/A-T CM800N3660 GMV-ND125PHS/A-T CM800N3670 GMV-ND140PHS/A-T CM800N3680 Part code Quantity Pump Drainpipe 05235301 Water Level Switch 45020216 Water Pump 43138220...
  • Page 284 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND160PHS/A-T: 13 14 Model GMV-ND160PHS/A-T Product Code CM810N0250 Qty. Part Name Part Code Electric Box Assy 100002070512 Main Board 30226000064 Terminal board 42000100000202 Terminal Board 4201800002601 Reactor 43138000047 Main Board...
  • Page 285 GREE Multi Variable Air Conditioners Indoor Units Model GMV-ND160PHS/A-T Product Code CM810N0250 Qty. Part Name Part Code Water Tray Assy 01285200025 Bottom Cover Plate Assy 01265200045 Top Cover Board Sub-assy 01265200082 Centrifugal Fan 10425200002 Propeller Housing(Lower) 26905200011 Brushless DC Motor...
  • Page 286 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND224PH/A-T CM800N3721 Part code Quantity Top Cover Board Assy 01265359 Evaporator Assy 01024100119 Display Board 30296000040 Hook 02112466 Water Tray Assy 000069060067 Bottom Cover Plate Assy...
  • Page 287 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND280PH/A-T: For the following unit Unit Product Code Name of part GMV-ND280PH/A-T CM800N3731 Part code Quantity Front Side Plate Sub-Assy 01314314 Blower Mounting Plate Sub-Assy 01324100066 Blower(Right) 1570411801 Brushless DC Motor...
  • Page 288: Low Static Pressure Duct Type

    GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND280PH/A-T CM800N3731 Part code Quantity Electric Expand Valve Fitting 4304413205 Bottom Cover Plate 01264212 Access plate 02224152 Right Side Plate 2 01314310 Seal Of Connection Pipe sub-assy...
  • Page 289 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22PLS/A-T CM800N3370 GMV-ND32PLS/A-T CM800N3390 Name of part GMV-ND25PLS/A-T CM800N3380 GMV-ND36PLS/A-T CM800N3500 GMV-ND28PLS/A-T CM800N3490 Part code Quantity Part code Quantity...
  • Page 290 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND40PLS/A-T, GMV-ND45PLS/A-T, GMV-ND50PLS/A-T: 10 11 12 13 14 15 For the following unit Unit Product Code GMV-ND40PLS/A-T CM800N3400 Name of part GMV-ND45PLS/A-T CM800N3410 GMV-ND50PLS/A-T CM800N3420 Part code Quantity Filter Sub-Assy...
  • Page 291 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND40PLS/A-T CM800N3400 Name of part GMV-ND45PLS/A-T CM800N3410 GMV-ND50PLS/A-T CM800N3420 Part code Quantity Terminal Board 4201800002601 Electric Box Cover 01424100035 Sealplate sub-assy (drainage) 01495315 Sealplate sub-assy (outlet)
  • Page 292 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56PLS/A-T、GMV-ND63PLS/A-T: 29 29 28 28 27 27 10 11 13 14 15 18 18 19 19 For the following unit For the following unit Unit Product Code Unit Product Code...
  • Page 293 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND56PLS/A-T CM800N3510 GMV-ND63PLS/A-T CM800N3430 Part code Quantity Part code Quantity Terminal Board 4201800002601 4201800002601 Electric Box Cover...
  • Page 294 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND71PLS/A-T, GMV-ND80PLS/A-T: 11 12 13 15 16 17 18 For the following unit Unit Product Code Name of part GMV-ND71PLS/A-T CM800N3520 GMV-ND80PLS/A-T CM800N3440 Part code Quantity Filter Sub-Assy 11725207 Air Intake Side Board Sub-assy...
  • Page 295 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND71PLS/A-T CM800N3520 GMV-ND80PLS/A-T CM800N3440 Part code Quantity Electric Box Assy 01394100205 Main Board 30226000029 Terminal Board 4201800002601 Terminal Board 42011106 Electric Box Cover...
  • Page 296 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND90PLS/A-T, GMV-ND100PLS/A-T, GMV-ND112PLS/A-T, GMV-ND125PLS/A-T, GMV-ND140PLS/A-T: 9 10 11 12 13 14 18 19 For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND90PLS/A-T CM800N3450 GMV-ND125PLS/A-T CM800N3480...
  • Page 297 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND90PLS/A-T CM800N3450 GMV-ND125PLS/A-T CM800N3480 Name of part GMV-ND100PLS/A-T CM800N3460 GMV-ND140PLS/A-T CM800N3470 GMV-ND112PLS/A-T CM800N3530 Part code Quantity Part code Quantity...
  • Page 298 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND18PLS/C-T、GMV-ND22PLS/C-T、GMV-ND25PLS/C-T、 GMV-ND28PLS/C-T: For the following unit Unit Product Code GMV-ND18PLS/C-T CM810N2030 Name of part GMV-ND22PLS/C-T CM810N1800 GMV-ND25PLS/C-T CM810N1810 GMV-ND28PLS/C-T CM810N1770 Part code Quantity Filter Sub-Assy 111001000082 Propeller Housing(Upper) 26905200018 Centrifugal Fan...
  • Page 299 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND18PLS/C-T CM810N2030 Name of part GMV-ND22PLS/C-T CM810N1800 GMV-ND25PLS/C-T CM810N1810 GMV-ND28PLS/C-T CM810N1770 Part code Quantity Electronic Expansion Valve 07334463 Liquid Level Switch 430024000005 Sealing Cap(Pressure Warning) 26112192...
  • Page 300 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND32PLS/C-T CM810N1820 GMV-ND36PLS/C-T CM810N1760 Part code Quantity 111001000082 Filter Sub-Assy 26905200018 Propeller Housing(Upper) 10425200003 Centrifugal Fan 150104060010 Brushless DC Motor 26905200019 Propeller Housing(Lower)
  • Page 301 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND40PLS/C-T、GMV-ND45PLS/C-T: 20 21 22 23 24 6 7 8 10 11 12 13 14 15 16 1718 19 For the following unit Unit Product Code Name of part GMV-ND40PLS/C-T CM810N1830...
  • Page 302 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND40PLS/C-T CM810N1830 GMV-ND45PLS/C-T CM810N1740 Part code Quantity Terminal Board 42011106 Main Board 300002060289 Electric Box Assy 100002063081 Drain Hose Sub-Assy 007008000001 Hook 2...
  • Page 303 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND50PLS/C-T、GMV-ND56PLS/C-T、GMV-ND63PLS/C-T: 20 21 22 23 24 6 7 8 10 11 12 13 14 15 16 1718 19 For the following unit Unit Product Code GMV-ND50PLS/C-T CM810N1840 Name of part...
  • Page 304 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND50PLS/C-T CM810N1840 Name of part GMV-ND56PLS/C-T CM810N1850 GMV-ND63PLS/C-T CM810N1730 Part code Quantity Terminal Board 42200006000401 Terminal Board 42011106 Main Board 300002060289 Electric Box Assy 100002063082 Drain Hose Sub-Assy...
  • Page 305 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND71PLS/C-T: 20 21 22 23 24 10 11 12 13 14 15 16 17 18 19 6 7 8 For the following unit Unit Product Code Name of part GMV-ND71PLS/C-T...
  • Page 306 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND71PLS/C-T CM810N1750 Part code Quantity Hook 2 01344100034 Left Side Plate Assy 000080000009 Corrugated Pipe 05015408 Water Tray Assy 01285200029 Liquid Level Switch...
  • Page 307 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND80PLS/C-T CM810N1920 Part code Quantity Filter Sub-Assy 11725207 Air Intake Side Board Sub-assy 02225265 Brushless DC Motor 150104060011 Volute Casing 200230060003 Centrifugal Fan...
  • Page 308 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND90PLS/C-T, GMV-ND100PLS/C-T, GMV-ND112PLS/C-T For the following unit Unit Product Code GMV-ND90PLS/C-T CM810N1960 Name of part GMV-ND100PLS/C-T CM810N1970 GMV-ND112PLS/C-T CM810N1950 Part code Quantity Filter Sub-Assy 11725206 Air Intake Side Board Sub-Assy...
  • Page 309 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND90PLS/C-T CM810N1960 Name of part GMV-ND100PLS/C-T CM810N1970 GMV-ND112PLS/C-T CM810N1950 Part code Quantity Bottom Cover Plate 01265343 Electric Box Assy 100002064928 Radiator 430034060043 Filter Board 300020060016 Terminal Board...
  • Page 310 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND125PLS/C-T, GMV-ND140PLS/C-T: For the following unit Unit Product Code Name of part GMV-ND125PLS/C-T CM810N1940 GMV-ND140PLS/C-T CM810N1930 Part code Quantity Filter Sub-Assy 11725206 Air Intake Side-Board Sub-Assy 02225261 Brushless DC Motor...
  • Page 311 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND125PLS/C-T CM810N1940 GMV-ND140PLS/C-T CM810N1930 Part code Quantity Terminal Board 42011106 Filter Board 300020060016 Terminal Board 42200006000401 Main Board 300002060459 Main Board 300002060399 Right Side Plate Assy...
  • Page 312 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND18PLS/C1-T 、 GMV-ND22PLS/C1-T 、 GMV-ND25PLS/C1-T 、 GMV-ND28PLS/C1-T、GMV-ND32PLS/C1-T、GMV-ND36PLS/C1-T: 9 10 11 12 13 14 15 For the following unit Unit Product Code Unit Product Code GMV-ND18PLS/C1-T CM810N2610 GMV-ND32PLS/C1-T CM810N2640 Name of part...
  • Page 313 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Unit Product Code GMV-ND18PLS/C1-T CM810N2610 GMV-ND32PLS/C1-T CM810N2640 Name of part GMV-ND22PLS/C1-T CM810N2620 GMV-ND36PLS/C1-T CM810N2570 GMV-ND25PLS/C1-T CM810N2630 — — GMV-ND28PLS/C1-T CM810N2580 — — Part code Quantity Part code...
  • Page 314 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND40PLS/C1-T 、 GMV-ND45PLS/C1-T 、 GMV-ND50PLS/C1-T 、 GMV-ND56PLS/C1-T、GMV-ND63PLS/C1-T: 9 10 11 12 13 14 15 16 17 18 For the following unit Unit Product Code Unit Product Code GMV-ND40PLS/C1-T CM810N2650 GMV-ND56PLS/C1-T...
  • Page 315 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Unit Product Code GMV-ND40PLS/C1-T CM810N2650 GMV-ND56PLS/C1-T CM810N2600 Name of part GMV-ND45PLS/C1-T CM810N2660 GMV-ND63PLS/C1-T CM810N2550 GMV-ND50PLS/C1-T CM810N2560 — — Part code Quantity Part code Quantity Hook 2...
  • Page 316 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND71PLS/C1-T、GMV-ND80PLS/C1-T: 11 12 13 14 15 16 17 18 19 For the following unit Unit Product Code Name of part GMV-ND71PLS/C1-T CM810N2590 GMV-ND80PLS/C1-T CM810N2540 Part code Quantity Filter Sub-Assy 111253039...
  • Page 317 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND71PLS/C1-T CM810N2590 GMV-ND80PLS/C1-T CM810N2540 Part code Quantity Electronic Expansion Valve 072009000005 Strainer 035021060019 Electric Expand Valve Fitting 4304000111 Rubber Plug 76815200002 Water Tray...
  • Page 318: 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 5.4 4-way Cassette Type Exploded View of GMV-ND28T/A-T, GMV-ND36T/A-T, GMV-ND45T/A-T, GMV-ND50T/A-T For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28T/A-T CM500N0380 GMV-ND45T/A-T CM500N0400 GMV-ND36T/A-T...
  • Page 319 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28T/A-T CM500N0380 GMV-ND45T/A-T CM500N0400 GMV-ND36T/A-T CM500N0390 GMV-ND50T/A-T CM500N0410 Part code Quantity Part code Quantity Strainer 07415200002...
  • Page 320 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56T/A-T, GMV-ND63T/A-T, GMV-ND71T/A-T, GMV-ND80T/A-T, GMV-ND90T/A-T, GMV-ND100T/A-T, GMV-ND112T/A-T, GMV-ND125T/A-T, GMV-ND140T/A-T. 20 21 22 23 24 25 26 27 28 For the following unit Unit Product Code GMV-ND56T/A-T CM500N0420 Name of part...
  • Page 321 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56T/A-T CM500N0420 Name of part GMV-ND63T/A-T CM500N0430 GMV-ND71T/A-T CM500N0440 GMV-ND80T/A-T CM500N0450 Part code Quantity Strainer 0741410000601 Electronic Expansion Valve 07334466 Rear Side Plate 01302714 Left Side Plate...
  • Page 322 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND90T/A-T CM500N0460 GMV-ND100T/A-T CM500N0470 Name of part GMV-ND112T/A-T CM500N0480 GMV-ND125T/A-T CM500N0490 GMV-ND140T/A-T CM500N0500 Part code Quantity Water Tray Assy 01289400013 Hook 02112721 Evaporator Assy 01024100116 Strainer...
  • Page 323 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND160T/A-T: For the following unit Unit Product Code Name of part GMV-ND160T/A-T CM500N0660 Part code Quantity Shell Assy 01519400001 Evaporator Assy 01024100103 Brushless DC Motor 15709400002 Centrifugal Fan 10429401 Diversion Circle...
  • Page 324: Compact 4-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND160T/A-T CM500N0660 Part code Quantity Strainer 0741410000601 Corrugated Pipe 035030000005 Sensor Sub-assy 39008000012G Remote Controller 30510589 Above data is subject to change without notice, pls reference the SP in global service website.
  • Page 325 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22T/B-T CM500N0610 GMV-ND36T/B-T CM500N0630 Name of part GMV-ND28T/B-T CM500N0620 GMV-ND45T/B-T CM500N0640 GMV-ND50T/B-T CM500N0600 Part Code Quantity Part Code Quantity...
  • Page 326 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56T/B-T: For the following unit Unit Product Code Name of part GMV-ND56T/B-T CM500N0650 Part Code Quantity Rear Grill 26909400007 Diversion Circle 10479400001 Centrifugal Fan 10429400001 Brushless DC Motor 1570940000401 Strainer...
  • Page 327 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND56T/B-T CM500N0650 Part Code Quantity Electric Box Assy 01394100456 Body Installing Support 01332705 Right Side Plate Sub-Assy 01319400013 Base Plate Assy 02229400007 Liquid Level Switch...
  • Page 328: 360°Air Discharge Compact Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 5.6 360°Air Discharge Compact Cassette Type Exploded View of GMV-ND15T/E-T, GMV-ND18T/E-T, GMV-ND22T/E-T, GMV-ND28T/E-T, GMV-ND36T/E-T, GMV-ND45T/E-T, GMV-ND50T/E-T For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND36T/E-T GMV-ND15T/E-T CM500N1690...
  • Page 329 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND36T/E-T GMV-ND15T/E-T CM500N1690 CM500N1330 GMV-ND45T/E-T Name of part GMV-ND18T/E-T CM500N1700 CM500N1310 GMV-ND50T/E-T GMV-ND22T/E-T CM500N1350 CM500N1320 GMV-ND28T/E-T CM500N1340 Part Code...
  • Page 330 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND56T/E-T CM500N1300 Part Code Quantity Electric Box Assy 100002062898 Terminal Board 42200006000401 Terminal Board 42011106 Main Board 300002000782 Flow Guide Loop 200150060003 Centifugal Fan...
  • Page 331: 2-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 5.7 2-way Cassette Type Exploded View of GMV-ND28TS/A-T, GMV-ND36TS/A-T, GMV-ND45TS/A-T, GMV-ND50TS/A-T For the following unit Unit Product Code GMV-ND28TS/A-T CM500N0680 GMV-ND36TS/A-T CM500N0690 Name of part GMV-ND45TS/A-T CM500N0700 GMV-ND50TS/A-T CM500N0710 Part Code Quantity Centrifugal fan assy...
  • Page 332 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND28TS/A-T CM500N0680 GMV-ND36TS/A-T CM500N0690 Name of part GMV-ND45TS/A-T CM500N0700 GMV-ND50TS/A-T CM500N0710 Part Code Quantity Electronic Expansion Valve 07334494 Strainer 0741410000601 Evaporator Assy 01024100094 Electric Box Assy...
  • Page 333 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56TS/A-T CM500N0720 Name of part GMV-ND63TS/A-T CM500N0730 GMV-ND71TS/A-T CM500N0740 Part Code Quantity Centrifugal fan assy 15404100048 Front Volute Casing 22202030 Centrifugal fan 10319051 Rear Volute Casing...
  • Page 334 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND28TS/B-T, GMV-ND36TS/B-T, GMV-ND45TS/B-T, GMV-ND50TS/B-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND28TS/B-T CM500N1770 GMV-ND36TS/B-T CM500N1760 Name of part GMV-ND45TS/B-T CM500N1780 GMV-ND50TS/B-T CM500N1750 Part Code...
  • Page 335 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND28TS/B-T CM500N1770 GMV-ND36TS/B-T CM500N1760 Name of part GMV-ND45TS/B-T CM500N1780 GMV-ND50TS/B-T CM500N1750 Part Code Quantity Part Code Quantity Strainer 035021060019...
  • Page 336 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56TS/B-T CM500N1790 GMV-ND63TS/B-T CM500N1800 Name of part GMV-ND71TS/B-T CM500N1810 GMV-ND80TS/B-T CM500N1740 Part Code Quantity Foam Sub- Assy 120011060018 Remote Controller 30510589 Drain Hose 05232046 Sensor Sub-assy...
  • Page 337: 1-Way Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 5.8 1-way Cassette Type Exploded View of GMV-ND22TD/A-T, GMV-ND28TD/A-T, GMV-ND36TD/A-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22TD/A-T CM502N0142 Name of part GMV-ND36TD/A-T CM502N0112 GMV-ND28TD/A-T CM502N0102...
  • Page 338 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22TD/A-T CM502N0142 Name of part GMV-ND36TD/A-T CM502N0112 GMV-ND28TD/A-T CM502N0102 Part code Quantity Part code Quantity Liquid Level Switch 43002400000501...
  • Page 339 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45TD/A-T, GMV-ND50TD/A-T: For the following unit Unit Product Code CM502N0122 Name of part GMV-ND45TD/A-T CM502N0132 GMV-ND50TD/A-T Part code Quantity Water Tray Sub-Assy 01284100011 Remote Controller 30510589 Drain Hose 05232046 Temperature Sensor...
  • Page 340 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code CM502N0122 Name of part GMV-ND45TD/A-T CM502N0132 GMV-ND50TD/A-T Part code Quantity Right Side Plate 01314100018 Tube-exit Plate 01344100018 Pump Drainpipe 26905288 Water Pump 4313822001 Electronic Expansion Valve...
  • Page 341 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56TD/A-T: For the following unit Unit Product Code Name of part CM502N0172 GMV-ND56TD/A-T Part code Quantity Water Tray Sub-Assy 01284100011 Corrugated Pipe 05015408 Remote Controller 30510589 Drain Hose 05232046 Temperature Sensor...
  • Page 342 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part CM502N0172 GMV-ND56TD/A-T Part code Quantity Right Side Plate 01314100018 Tube-exit Plate 01344100018 Pump Drainpipe 26905288 Water Pump 4313822001 Electronic Expansion Valve 07334494 Strainer...
  • Page 343 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND63TD/B-T, GMV-ND71TD/B-T, GMV-ND80TD/B-T: For the following unit Unit Product Code GMV-ND63TD/B-T CM503N1060 Name of part GMV-ND71TD/B-T CM502N0190 GMV-ND80TD/B-T CM502N0200 Part code Quantity Behind Cover Plate 012035061674 Electric Box Assy 100002074743...
  • Page 344 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND63TD/B-T CM503N1060 Name of part GMV-ND71TD/B-T CM502N0190 GMV-ND80TD/B-T CM502N0200 Part code Quantity Top Cover 012148060440 Left Side Plate 012055060503 Hook 012045060010 Sensor Sub-assy 390002000005 Remote Controller...
  • Page 345: Floor Ceiling Type

    GREE Multi Variable Air Conditioners Indoor Units 5.9 Floor Ceiling Type Exploded View of GMV-ND28ZD/A-T, GMV-ND36ZD/A-T, GMV-ND50ZD/A-T, GMV-ND56ZD/A-T : For the following unit Unit Product Code GMV-ND28ZD/A-T CM600N0350 Name of part GMV-ND36ZD/A-T CM600N0360 GMV-ND50ZD/A-T CM600N0320 GMV-ND56ZD/A-T CM600N0400 Part code Quantity...
  • Page 346 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND28ZD/A-T CM600N0350 Name of part GMV-ND36ZD/A-T CM600N0360 GMV-ND50ZD/A-T CM600N0320 GMV-ND56ZD/A-T CM600N0400 Part code Quantity Guide Louver Supporter Sub-Assy 0180941601 Fixed Mount(Display board) 26909426R Display Board 30294000009...
  • Page 347 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND63ZD/A-T, GMV-ND71ZD/A-T, GMV-ND90ZD/A-T: For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Remote Controller 30510589 Sensor Sub-assy 39008000100G Water Tray Assy...
  • Page 348 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Water Releasing Flume 26909441 connected board (evaporator) 01344108 Strainer 0741410000601 Electronic Expansion Valve 07334466...
  • Page 349 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Rotary Axis Sub-Assy 73018052 Joint Slack 73018731 Motor Support Sub-Assy 01809400029 Brushless DC Motor...
  • Page 350 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND112ZD/A-T CM600N0380 Name of part GMV-ND125ZD/A-T CM600N0390 GMV-ND140ZD/A-T CM600N0340 GMV-ND160ZD/A-T CM600N0500 Part code Quantity Remote Controller 30510589 Sensor Sub-assy 39008000100G Water Tray Assy 01289401 Air Louver...
  • Page 351 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND112ZD/A-T CM600N0380 Name of part GMV-ND125ZD/A-T CM600N0390 GMV-ND140ZD/A-T CM600N0340 GMV-ND160ZD/A-T CM600N0500 Part code Quantity Terminal Board 4201800002601 Inductance 43128000014 Support Of Motor Bearing 01792408 O-Gasket of Bearing...
  • Page 352 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND28ZD/B-T, GMV-ND36ZD/B-T, GMV-ND50ZD/B-T, GMV-ND56ZD/B-T : For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28ZD/B-T CM600N0570 GMV-ND50ZD/B-T CM600N0510 GMV-ND36ZD/B-T CM600N0540 GMV-ND56ZD/B-T CM600N0580...
  • Page 353 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28ZD/B-T CM600N0570 GMV-ND50ZD/B-T CM600N0510 GMV-ND36ZD/B-T CM600N0540 GMV-ND56ZD/B-T CM600N0580 Part code Quantity Part code Quantity Display Board...
  • Page 354 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND63ZD/B-T CM600N0590 GMV-ND71ZD/B-T CM600N0550 Part code Quantity Terminal board 42000100000204 Left Side Plate 2690940007001 Support of Motor Bearing 01792408 Propeller Housing(Lower) 200230000001 O-Gasket of Baring...
  • Page 355 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND90ZD/B-T: For the following unit Unit Product Code Name of part GMV-ND90ZD/B-T CM600N0520 Part code Quantity Seat Board Sub-Assy 017080000052 Electric Box Assy 100002070924 Inductance 43128000014 Main Board 300002061965 Terminal Board...
  • Page 356 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND90ZD/B-T CM600N0520 Part code Quantity Drainage Pipe Sub-Assy 05235434 Evaporator Assy 011001061579 Corrugated Pipe 0502511201 Strainer 0721304401 Electric Expand Valve 072009060046 Display Board...
  • Page 357 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND112ZD/B-T CM600N0610 GMV-ND125ZD/B-T CM600N0530 Part code Quantity Main Board 300002061965 Terminal Board 42200006005404 Terminal Board 42000100000204 Electric Box Assy 100002070925 Support Of Motor Bearing...
  • Page 358 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND140ZD/B-T, GMV-ND160ZD/B-T: For the following unit Unit Product Code Name of part GMV-ND140ZD/B-T CM600N0600 GMV-ND160ZD/B-T CM600N0560 Part code Quantity Seat Board Sub-Assy 017080060020 Left Side Plate 2690940007001 Electric Box Assy...
  • Page 359: Fresh Air Processing Unit

    GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND140ZD/B-T CM600N0600 GMV-ND160ZD/B-T CM600N0560 Part code Quantity Strainer 0721304401 Electronic Expansion Valve 072009060045 Electric Expand Valve Fitting 4304413203 Strainer 035021060019 Right Side Plate...
  • Page 360 GREE Multi Variable Air Conditioners Indoor Units Model GMV-NX140P/A(X1.2)-K Product Code CM800N3610 Quantity Part Name Part Code Electric Box Assy 01394100199 Left Side Plate Assy 01314100058 Seal Of Left Side Plate Sub-Assy 01495212 Seal Of Connection Pipe 01495213 Bottom Cover Plate Assy...
  • Page 361 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-NX224P/A(X2.0)-M: Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Quantity Part Name Part Code Electric Box Cover 014191411 AC Contactor 44010287 Terminal Board 42000100000401 Terminal Board 4201800002601 Main Board 30226000052 Electric Box Assy...
  • Page 362 GREE Multi Variable Air Conditioners Indoor Units Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Quantity Part Name Part Code Place with a draught of Connection board 01389079 Place with a draught of Connection board 01389077 Rear beam sub-assy 01779108 Motor Retaining Plate Sub-Assy...
  • Page 363 GREE Multi Variable Air Conditioners Indoor Units Model GMV-NX280P/A(X2.5)-M GMV-NX280P/A(X3.0)-M Product Code CM800N3630 CM800N3630 Quantity Part Name Part Code Part Code Right Side Plate Sub-Assy 01314209 01314209 Side beam assy 01874178 01874178 Chassis Sub-assy 01194136 01194136 Water Collecting Tray Assy...
  • Page 364 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-NX450P/A(X4.0)-M: Model GMV-NX450P/A(X4.0)-M Product Code CM800N3740 Quantity Part Name Part Code Electric Box Cover 01425304P Electric Box Assy 01394100243 Terminal Board 42018000593 AC Contactor 44010287 Terminal Board 4201800002601 Main Board...
  • Page 365 GREE Multi Variable Air Conditioners Indoor Units Model GMV-NX450P/A(X4.0)-M Product Code CM800N3740 Quantity Part Name Part Code Gas Tube Filter 072190511 Side panel sub-assy 01545208 Side panel sub-assy 01545210 Fan Motor 1570600000501 Belt Wheel 10548150 Taper Sleeve 10548213 Taper Sleeve...
  • Page 366 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-NDX125P/A-T CM810N1220 GMV-NDX140P/A-T CM810N1020 Part code Quantity Filter Sub-Assy 111001000052 Return Air Frame Sub-Assy 017026000003 Propeller Housing(Upper) 26905200078 Fan Bearing 7651221001 Propeller Housing(Lower)
  • Page 367 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-NDX224P/A-T, GMV-NDX250P/A-T, GMV-NDX280P/A-T: 严 禁 在 潮 湿 场 所使 用 For the following unit For the following unit Unit Product Code Unit Product Code GMV-NDX224P/ GMV-NDX280P/ CM810N0260 CM810N0270 Name of part...
  • Page 368 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-NDX224P/ GMV-NDX280P/ CM810N0260 CM810N0270 Name of part GMV-NDX250P/ CM810N1230 Part code Quantity Part code Quantity Electric Box Assy 01394100573...
  • Page 369: Slim Duct Type

    GREE Multi Variable Air Conditioners Indoor Units 5.11 Slim Duct Type Exploded View of GMV-ND22PL/B-T, GMV-ND25PL/B-T, GMV-ND28PL/B-T, GMV-ND32PL/B-T GMV-ND36PL/B-T: For the following unit Unit Product Code GMV-ND22PL/B-T CM800N3560 GMV-ND25PL/B-T CM810N0010 Name of part GMV-ND28PL/B-T CM810N0020 GMV-ND32PL/B-T CM800N3570 GMV-ND36PL/B-T CM810N0030 Part code...
  • Page 370 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22PL/B-T CM800N3560 GMV-ND25PL/B-T CM810N0010 Name of part GMV-ND28PL/B-T CM810N0020 GMV-ND32PL/B-T CM800N3570 GMV-ND36PL/B-T CM810N0030 Part code Quantity Closing Plate Sub-Assy 01494100010 Left Side Plate Assy 01314100076 Air Outlet Frame Assy...
  • Page 371 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND40PL/B-T CM800N3580 GMV-ND45PL/B-T CM810N0040 Name of part GMV-ND50PL/B-T CM810N0050 GMV-ND56PL/B-T CM800N3590 GMV-ND63PL/B-T CM810N0060 Part code Quantity Centrifugal fan assy 15404100032 Centrifugal Fan 10425200003 Fan Bearing 76512210...
  • Page 372 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND72PL/B-T: For the following unit Unit Product Code Name of part GMV-ND72PL/B-T CM800N3600 Part code Quantity Centrifugal fan assy 15404100032 Bearing Holder Sub-assy 26151139 Centrifugal Fan 10425200003 Fan Bearing 76512210...
  • Page 373 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND72PL/B-T CM800N3600 Part code Quantity Top Cover Board Assy 0126520009201 Hook 01344100034 Display Board 30296000040 Sensor Sub-assy 39004168G Above data is subject to change without notice, pls reference the SP in global service website.
  • Page 374 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22SPL/B1-T CM810N1580 GMV-ND25SPL/B1-T CM810N1570 Name of part GMV-ND28SPL/B1-T CM810N1340 GMV-ND32SPL/B1-T CM810N1560 GMV-ND36SPL/B1-T CM810N1330 Part code Quantity Blower Mounting Plate Sub-Assy 01325200034 Cover Plate(Air return) 01265200057 Bottom Cover Plate Assy...
  • Page 375 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND40PLS/B1-T, GMV-ND45PLS/B1-T, GMV-ND50PLS/B1-T, GMV-ND56PLS/B1-T, GMV-ND63PLS/B1-T: For the following unit Unit Product Code GMV-ND40SPL/B1-T CM810N1550 Name of part GMV-ND45SPL/B1-T CM810N1350 GMV-ND50SPL/B1-T CM810N1540 GMV-ND56SPL/B1-T CM810N1530 GMV-ND63SPL/B1-T CM810N1360 Display Board 300001000054 Sensor Sub-Assy 390002000005...
  • Page 376 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND40SPL/B1-T CM810N1550 Name of part GMV-ND45SPL/B1-T CM810N1350 GMV-ND50SPL/B1-T CM810N1540 GMV-ND56SPL/B1-T CM810N1530 GMV-ND63SPL/B1-T CM810N1360 Left Side Plate Assy 1314100136 Drain Hose Sub-Assy 5232050 Water Level Switch 4501270303...
  • Page 377 GREE Multi Variable Air Conditioners Indoor Units For the following unit Name of part Unit Product Code GMV-ND40SPL/B1-T CM810N1550 Fan Bearing 76512210 Propeller Housing(Upper) 26905200018 Centrifugal Fan 10425200003 Joint Slack 73018731 Motor Support 01805200144 Brushless DC Motor 15704100001 Rotary Axis Sub-Assy...
  • Page 378: Console Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 5.12 Console Type Indoor Unit Exploded View of GMV-ND22C/A-T, GMV-ND28C/A-T, GMV-ND36C/A-T, GMV-ND45C/A-T, GMV-ND50C/A-T: For the following unit Unit Product Code GMV-ND22C/A-T CM400N0140 GMV-ND28C/A-T CM400N0070 Name of part GMV-ND36C/A-T CM400N0080 GMV-ND45C/A-T CM400N0150 GMV-ND50C/A-T CM400N0090...
  • Page 379 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22C/A-T CM400N0140 GMV-ND28C/A-T CM400N0070 Name of part GMV-ND36C/A-T CM400N0080 GMV-ND45C/A-T CM400N0150 GMV-ND50C/A-T CM400N0090 Part code Quantity Electronic Expansion Valve 7334282 Electric Expand Valve Fitting 4304000102 Electric Box Assy...
  • Page 380: Wall Mounted Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 5.13 Wall Mounted type Indoor Unit Exploded View of GMV-N22G/A3A-K, GMV-N28G/A3A-K: For the following unit Unit Product Code Name of part GMV-N22G/A3A-K CM100N1350 GMV-N28G/A3A-K CM100N1340 Part code Quantity Receiver Window 22432230 Guide Louver...
  • Page 381 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-N22G/A3A-K CM100N1350 GMV-N28G/A3A-K CM100N1340 Part code Quantity Terminal Board 42010268 Electric Box 2011216702 Connecting pipe clamp 26112164 Stepping Motor 1521212901 Crank 10582070 Wall Mounting Frame...
  • Page 382 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-N36G/A3A-K CM100N1360 Name of part GMV-N45G/A3A-K CM100N1370 GMV-N50G/A3A-K CM100N1330 Part code Quantity Receiver Window 22432173 Guide Louver 10512115 Front Panel Assy 20012260 Filter Sub-Assy 1112000000 Front Case Sub-assy...
  • Page 383 GREE Multi Variable Air Conditioners Indoor Units GMV-N56G/A3A-K, GMV-N63G/A3A-K, GMV-N71G/A3A-K: For the following unit Unit Product Code GMV-N56G/A3A-K CM100N1380 Name of part GMV-N63G/A3A-K CM100N1390 GMV-N71G/A3A-K CM100N1340 Part code Quantity Receiver Window 22432173 Guide Louver 10512118 Front Panel Assy 20012328 Filter Sub-Assy...
  • Page 384 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-N56G/A3A-K CM100N1380 Name of part GMV-N63G/A3A-K CM100N1390 GMV-N71G/A3A-K CM100N1340 Part code Quantity Terminal Board 4201026805 Electric Box 01394100336 Connecting pipe clamp 26112188 Stepping Motor 1521300101 Crank...
  • Page 385 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND22G/A3A-T CM100N2560 GMV-ND28G/A3A-T CM100N2600 Part code Quantity Receiver Window 22432230 Guide Louver 10512157 Front Panel A3 20012123C Filter Sub-Assy 1112220403 Front Case Sub-assy...
  • Page 386 GREE Multi Variable Air Conditioners Indoor Units Exploded View o GMV-ND36G/A3A-T、GMV-ND45G/A3A-T、GMV-ND50G/A3A-T: For the following unit Unit Product Code GMV-ND36G/A3A-T CM100N2590 Name of part GMV-ND45G/A3A-T CM100N2580 GMV-ND50G/A3A-T CM100N2610 Part code Quantity Receiver Window 22432173 Guide Louver 10512115 Front Panel Assy 20022146...
  • Page 387 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND36G/A3A-T CM100N2590 Name of part GMV-ND45G/A3A-T CM100N2580 GMV-ND50G/A3A-T CM100N2610 Part code Quantity Lower Shield of Electric Box 1592091 Electric Box Assy 1394000000 Main Board 300002000703 Terminal Board...
  • Page 388 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/A3A-T CM100N2570 Name of part GMV-ND63G/A3A-T CM100N2550 GMV-ND71G/A3A-T CM100N2540 Part code Quantity 22432173 Receiver Window 10512118 Guide Louver 20012328 Front Panel Assy 11122091 Filter Sub-Assy Front Case Assy...
  • Page 389 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND80G/A3A-T 、 GMV-ND90G/A3A-T 、 GMV-ND100G/A3A-T 、 GMV-ND80G/B4B-T、GMV-ND90G/B4B-T、GMV-ND100G/B4B-T:...
  • Page 390 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80G/A3A-T CM100N2620 Name of part GMV-ND90G/A3A-T CM100N2630 GMV-ND100G/A3A-T CM100N2640 Part code Quantity Receiver Window 22432164 Front Panel 20012490S Stand Bar 24212120 Filter Sub-Assy 11122106 Front Case Sub-assy...
  • Page 391 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80G/A3A-T CM100N2620 Name of part GMV-ND90G/A3A-T CM100N2630 GMV-ND100G/A3A-T CM100N2640 Part code Quantity Electric Box Cover 2011204404S Remote Controller 30510589 Electric Expand Valve Fitting 4304413217 Fan Bearing...
  • Page 392 GREE Multi Variable Air Conditioners Indoor Units...
  • Page 393 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80G/B4B-T CM100N2930 Name of part GMV-ND90G/B4B -T CM100N2940 GMV-ND100G/B4B -T CM100N2840 Part code Quantity Receiver Window 22432164 Front Panel 20022158C Stand Bar 2421212001 Filter Sub-Assy 1112210601...
  • Page 394 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80G/B4B-T CM100N2930 Name of part GMV-ND90G/B4B -T CM100N2940 GMV-ND100G/B4B -T CM100N2840 Part code Quantity Temperature Sensor 390002072 Temperature Sensor 39000076G Temperature Sensor 390000454 Above data is subject to change without notice, pls reference the SP in global service website.
  • Page 395 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND15G/B6B-T CM100N3300 GMV-ND18G/B6B-T CM100N3310 Name of part GMV-ND22G/B6B-T CM100N3240 GMV-ND28G/B6B-T CM100N3270 GMV-ND36G/B6B-T CM100N3210 Part code Quantity Front Panel 20000300049T Filter Sub-Assy 11122468 Front CaseAssy 00000200045 Air Louver1...
  • Page 396 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND15G/B4B-T 、 GMV-ND18G/B4B-T 、 GMV-ND22G/B4B-T 、 GMV-ND28G/B4B-T、 GMV-ND36G/B4B-T: For the following unit Unit Product Code GMV-ND15G/B4B-T CM100N3280 GMV-ND18G/B4B-T CM100N3290 Name of part GMV-ND22G/B4B-T CM100N2770 GMV-ND28G/B4B-T CM100N2780 GMV-ND36G/B4B-T CM100N2760 Part code Quantity...
  • Page 397 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND15G/B4B-T CM100N3280 GMV-ND18G/B4B-T CM100N3290 Name of part GMV-ND22G/B4B-T CM100N2770 GMV-ND28G/B4B-T CM100N2780 GMV-ND36G/B4B-T CM100N2760 Part code Quantity Fan Motor 1501246601 Stepping Motor 1521210710 Crank 73012005 Rubber Plug(WaterTray)
  • Page 398 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND22G/C4B-T、GMV-ND28G/C4B-T、GMV-ND36G/C4B-T:...
  • Page 399 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22G/C4B-T CM100N3140 Name of part GMV-ND28G/C4B-T CM100N3130 GMV-ND36G/C4B-T CM100N3150 Part code Quantity Front Panel 20000300098S Filter Sub-Assy 11122468 Front CaseAssy 00000200045 Air Louver1 10512723 Helicoid Tongue...
  • Page 400 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND22G/C2B-T、GMV-ND28G/C2B-T、GMV-ND36G/C2B-T:...
  • Page 401 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22G/C2B-T CM100N3040 Name of part GMV-ND28G/C2B-T CM100N3080 GMV-ND36G/C2B-T CM100N3050 Part code Quantity Front Panel 20000300069S Filter Sub-Assy 11122468 Front CaseAssy 00000200045 Air Louver1 10512723 Helicoid Tongue...
  • Page 402 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND22G/D2B-T、GMV-ND28G/D2B-T、GMV-ND36G/D2B-T:...
  • Page 403 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22G/D2B-T CM100N2850 Name of part GMV-ND28G/D2B-T CM100N2860 GMV-ND36G/D2B-T CM100N2870 Part code Quantity Front Panel 00000300003303 Filter Sub-Assy 11122468 Front CaseAssy 00000200000703 Air Louver1 10512723 Helicoid Tongue...
  • Page 404 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45G/B6B-T、GMV-ND50G/B6B-T:...
  • Page 405 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45G/B6B-T CM100N3250 GMV-ND50G/B6B-T CM100N3200 Part code Quantity Front Panel 20000300040T Filter Sub-Assy 1112208906 Front CaseAssy 00000200042 Air Louver1 10512732 Helicoid Tongue 26112512 Air Louver2...
  • Page 406 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45G/B4B-T、GMV-ND50G/B4B-T:...
  • Page 407 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45G/B4B-T CM100N2790 GMV-ND50G/B4B-T CM100N2800 Part code Quantity Front Panel 20000300028T Filter Sub-Assy 1112208906 Front CaseAssy 00000200042 Air Louver1 10512732 Helicoid Tongue 26112512 Air Louver2...
  • Page 408 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45G/C4B-T、GMV-ND50G/C4B-T:...
  • Page 409 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45G/C4B-T CM100N3120 GMV-ND50G/C4B-T CM100N3160 Part code Quantity Front Panel 20000300106S Filter Sub-Assy 1112208906 Front CaseAssy 00000200042 Air Louver1 10512732 Helicoid Tongue 26112512 Air Louver2...
  • Page 410 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45G/C2B-T、GMV-ND50G/C2B-T:...
  • Page 411 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45G/C2B-T CM100N3060 GMV-ND50G/C2B-T CM100N3070 Part code Quantity Front Panel 20000300070S Filter Sub-Assy 1112208906 Front CaseAssy 00000200042 Air Louver1 10512732 Helicoid Tongue 26112512 Air Louver2...
  • Page 412 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45G/D2B-T、GMV-ND50G/D2B-T:...
  • Page 413 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45G/D2B-T CM100N2880 GMV-ND50G/D2B-T CM100N2890 Part code Quantity Front Panel 00000300003104 Filter Sub-Assy 1112208906 Front CaseAssy 0000020004203 Air Louver1 10512732 Helicoid Tongue 26112512 Air Louver2...
  • Page 414 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56G/B6B-T、GMV-ND63G/B6B-T、GMV-ND71G/B6B-T:...
  • Page 415 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/B6B-T CM100N3240 Name of part GMV-ND63G/B6B-T CM100N3230 GMV-ND71G/B6B-T CM100N3220 Part code Quantity Front Panel 20000300048T Filter Sub-Assy 1101200703 Front CaseAssy 00000200043 Air Louver 1 10512737 Helicoid Tongue...
  • Page 416 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56G/B4B-T、GMV-ND63G/B4B-T、GMV-ND71G/B4B-T:...
  • Page 417 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/B4B-T CM100N2810 Name of part GMV-ND63G/B4B-T CM100N2820 GMV-ND71G/B4B-T CM100N2830 Part code Quantity Front Panel 20000300029T Filter Sub-Assy 1101200703 Front CaseAssy 00000200043 Air Louver 1 10512737 Helicoid Tongue...
  • Page 418 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56G/C4B-T、GMV-ND63G/C4B-T、GMV-ND71G/C4B-T:...
  • Page 419 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/C4B-T CM100N3170 Name of part GMV-ND63G/C4B-T CM100N3180 GMV-ND71G/C4B-T CM100N3190 Part code Quantity Front Panel 20000300099S Filter Sub-Assy 1101200703 Front CaseAssy 00000200043 Air Louver 1 10512737 Helicoid Tongue...
  • Page 420 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56G/C2B-T、GMV-ND63G/C2B-T、GMV-ND71G/C2B-T:...
  • Page 421 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/C2B-T CM100N3110 Name of part GMV-ND63G/C2B-T CM100N3100 GMV-ND71G/C2B-T CM100N3090 Part code Quantity Front Panel 20000300071S Filter Sub-Assy 1101200703 Front CaseAssy 00000200043 Air Louver 1 10512737 Helicoid Tongue...
  • Page 422 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56G/D2B-T、GMV-ND63G/D2B-T、GMV-ND71G/D2B-T:...
  • Page 423 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56G/D2B-T CM100N2900 Name of part GMV-ND63G/D2B-T CM100N2910 GMV-ND71G/D2B-T CM100N2920 Part code Quantity Front Panel 0000030023501 Filter Sub-Assy 1101200703 Front CaseAssy 0000020017301 Air Louver 1 10512737 Helicoid Tongue...
  • Page 424: Super High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 5.14 Super High Static Pressure Duct Type Indoor Unit Exploded View GMV-ND22PHS/B-T, GMV-ND25PHS/B-T, GMV-ND28PHS/B-T, GMV-ND32PHS/B-T, GMV-ND36PHS/B-T: For the following unit Unit Product Code GMV-ND22PHS/B-T CM810N0300 GMV-ND25PHS/B-T CM810N0310 Name of part GMV-ND28PHS/B-T CM810N0320 GMV-ND32PHS/B-T...
  • Page 425 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22PHS/B-T CM810N0300 GMV-ND25PHS/B-T CM810N0310 Name of part GMV-ND28PHS/B-T CM810N0320 GMV-ND32PHS/B-T CM810N0330 GMV-ND36PHS/B-T CM810N0340 Part code Quantity Filter Sub-Assy 111001000055 Return Air Frame Sub-Assy 017026000004 Cover Of Air-In...
  • Page 426 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND40PHS/B-T, GMV-ND45PHS/B-T, GMV-ND50PHS/B-T: For the following unit Unit Product Code GMV-ND40PHS/B-T CM810N0350 Name of part GMV-ND45PHS/B-T CM810N0360 GMV-ND50PHS/B-T CM810N0370 Part code Quantity Display Board 30296000040 Drain Hose Sub-Assy 05232050 Temperature Sensor...
  • Page 427 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND40PHS/B-T CM810N0350 Name of part GMV-ND45PHS/B-T CM810N0360 GMV-ND50PHS/B-T CM810N0370 Part code Quantity Bottom Cover Plate 01265200181 Left Side Plate Assy 01315200147 Inductance 43128000014 Terminal Board 4201115402...
  • Page 428 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND56PHS/B-T, GMV-ND63PHS/B-T, GMV-ND71PHS/B-T, GMV-ND80PHS/B-T: 26 25 21 20 严 禁 在 潮 湿 场 所 使 用 16 17 For the following unit Unit Product Code GMV-ND56PHS/B-T CM810N0380 Name of part...
  • Page 429 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56PHS/B-T CM810N0380 Name of part GMV-ND63PHS/B-T CM810N0390 GMV-ND71PHS/B-T CM810N0400 GMV-ND80PHS/B-T CM810N0410 Part code Quantity Electric Box Assy 100002000985 Water Level Switch 45020216 Temperature Sensor 3900005910 Temperature Sensor...
  • Page 430 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND90PHS/B-T, GMV-ND100PHS/B-T, GMV-ND112PHS/B-T, GMV-ND125PHS/B-T: 27 26 25 严禁在 潮湿场 所使 用 20 21 22 15 16 17 18 19 9 10 11 13 14 For the following unit Unit Product Code...
  • Page 431 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND90PHS/B-T CM810N0420 Name of part GMV-ND100PHS/B-T CM810N0430 GMV-ND112PHS/B-T CM810N0440 GMV-ND125PHS/B-T CM810N0450 Part code Quantity Bottom Cover Plate 01265200125 Left Side Plate Assy 01315200147 Hook 02112466 Water Level Switch...
  • Page 432 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND140PHS/B-T, GMV-ND160PHS/B-T 27 26 25 严 禁 在潮 湿 场 所 使用 9 10 11 13 14 15 16 17 18 19 21 22 23 For the following unit Unit...
  • Page 433 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND140PHS/B-T CM810N0460 GMV-ND160PHS/B-T CM810N0840 Part code Quantity Main Board 30226000092 Terminal board 42000100000101 Terminal Board 4201800002601 Electric Box Assy 100002001967 Water Level Switch...
  • Page 434 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND180PHS/B-T For the following unit Unit Product Code Name of part GMV-ND180PHS/B-T CM810N2240 Part code Quantity Filter Sub-Assy 111001000052 Return Air Frame Sub-Assy 017026000003 Centrifugal fan assy 000052000029 Propeller Housing(Upper)
  • Page 435 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND180PHS/B-T CM810N2240 Part code Quantity Main Board 30221000033 Reactor 43138000047 Main Board 300002061641 Terminal Board 42000100000101 Terminal Board 42200006000401 Electric Box Assy 100002070712...
  • Page 436 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND400PH/AR-X For the following unit Unit Product Code Name of part GMV-ND400PH/AR-X CM810N1510 Part code Quantity Top Cover Board Sub-assy 017011000039 Left Side Plate Assy 000080000020 Water Collecting Tray Assy...
  • Page 437 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND400PH/AR-X CM810N1510 Part code Quantity Electric Expand Valve Fitting 4304413271 Filter 07219056 Filter Sub-assy 1 11129078 Filter Sub-assy 2 11129079 Sens or Sub-assy...
  • Page 438 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND450PH/AR-X CM810N1520 Part code Quantity Terminal Board 42000100000401 Terminal Board 4201800002601 Main Board 30226000092 Main Board 300002000380 Reactor 43130189 Radiator 49018000013 Side Plate...
  • Page 439 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-N560PH/AR-M CM810N1610 Part code Quantity Air Outlet Panel Assy 01545317 Blower 15019241 Base Frame Assy 000043060052 Belt Wheel 10548156 Belt 76318356 Belt Wheel...
  • Page 440: Ahu-Kit Type

    GREE Multi Variable Air Conditioners Indoor Units 5.15 AHU-KIT Type Exploded View of GMV-N36U/A-T, GMV-N71U/A-T, GMV-N140U/A-T, GMV-N280U/A-T,: GMV-N36U/A-T: Model GMV-N36U/A-T Product Code CN750N0040 Qty. Part Name Part Code Electric Box Assy 01394100511 Electric Box Cover 01424100135P Terminal Board 42000100000101 Terminal Board...
  • Page 441 GREE Multi Variable Air Conditioners Indoor Units Model GMV-N71U/A-T Product Code CN750N0050 Qty. Part Name Part Code Terminal Board 42000100000101 Terminal Board 422000000025 Terminal Board 4201800002601 Main Board 30226000081 Electronic Expansion Valve Assy 030026000085 Cover Plate 01264100061P Strainer 0741410000601 Electric Expand Valve Fitting...
  • Page 442 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N560U/A-T Model GMV-N5600U/A-T Product Code CN750N0010 Qty. Part Name Part Code Electronic Expansion Valve Assy 43044100220 Cover Plate 01264100063P Electric Expand Valve Fitting 4304413239 Electronic Expansion Valve 07331139 Bidirection Strainer...
  • Page 443 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N36U/B-T, GMV-N71U/B-T, GMV-N140U/B-T, GMV-N280U/B-T: GMV-N36U/B-T: Model GMV-N36U/B-T Product Code CN750N0110 Qty. Part Name Part Code Electric Box Assy 100002060732 Transformer 43110286 Main Board 30226000081 Terminal Board 42000100000101 Terminal Board 422000000025...
  • Page 444 GREE Multi Variable Air Conditioners Indoor Units Model GMV-N71U/B-T Product Code CN750N0150 Qty. Part Name Part Code Terminal Board 4201800002601 Terminal Board 42011147 Electronic Expansion Valve assy 030174060014 Electric Expand Valve Fitting 4304413239 Electronic Expansion Valve 072009000001 Strainer 0741520000201 Display Board...
  • Page 445 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N560U/B-T: 4 5 6 7 13 14 Model GMV-N560U/B-T Product Code CN750N0130 Qty. Part Name Part Code Electric Box Assy 100002060732 Transformer 43110286 Main Board 30226000081 Terminal Board 42000100000101 Terminal Board...
  • Page 446 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N36U/C-T: Model GMV-N36U/C-T Product Code CN750N0190 Qty. Part Name Part Code Electric Box Assy 100002066409 Terminal Board 422000000009 Terminal Board 42200006000401 Terminal Board 42200006000901 Main Board 300002060941 Terminal Board 42000100000101...
  • Page 447 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N71U/C-T, GMV-N140U/C-T, GMV-N280U/C-T: For the following unit Unit Product Code GMV-N71U/C-T CN750N0200 Name of part GMV-N140U/C-T CN750N0180 GMV-N280U/C-T CN750N0170 Part code Quantity Electric Box Assy 100002066409 Terminal Board 422000000009 Terminal Board...
  • Page 448 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-N560U/C-T: 4 5 6 7 Model GMV-N560U/C-T Product Code CN750N0160 Qty. Part Name Part Code Electric Box Assy 100002066409 Terminal Board 422000000009 Terminal Board 42200006000401 Terminal Board 42200006000901 Main Board...
  • Page 449: Concealed Floor Standing Type

    GREE Multi Variable Air Conditioners Indoor Units 5.16 Concealed Floor Standing Type Exploded View of GMV-ND22ZA/A-T, GMV-ND28ZA/A-T, GMV-ND36ZA/A-T: 24 24 23 23 22 22 21 21 20 20 19 19 18 18 17 17 16 16 15 15 14 14...
  • Page 450 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22ZA/A-T CM810N1490 Name of part GMV-ND28ZA/A-T CM810N1480 GMV-ND36ZA/A-T CM810N1460 Part code Quantity Terminal Board 4201800002601 Terminal Board 42000100000101 Main Board 30226000029 Electric Box Assy 100002004224 Left Side Plate Assy...
  • Page 451 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45ZA/A-T: 26 26 26 26 25 25 25 25 24 24 24 24 23 23 23 23 22 22 22 22 21 21 21 21 20 20 20 20 19 19...
  • Page 452 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45ZA/A-T CM810N1470 Part code Quantity Left Side Plate Assy 01315200087 Terminal Board 4201800002601 Terminal Board 42000100000101 Main Board 30226000029 Electric Box Assy 100002004224...
  • Page 453 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56ZA/A-T CM810N1451 Name of part GMV-ND63ZA/A-T CM810N1440 GMV-ND71ZA/A-T CM810N1430 Part code Quantity Supporter 012060002587 Filter Sub-Assy 111001060010 Iron Grill 012051060107 Front Volute Casing 26905205 Centrifugal Fan...
  • Page 454: 360°Air Discharge Cassette Type

    GREE Multi Variable Air Conditioners Indoor Units 5.17 360°Air Discharge Cassette Type Exploded View of GMV-ND22T/C-T,GMV-ND28T/C-T: For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND22T/C-T CM500N1680 GMV-ND36T/C-T CM500N1670 GMV-ND28T/C-T CM500N1660 GMV-ND45T/C-T...
  • Page 455 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND22T/C-T CM500N1680 GMV-ND36T/C-T CM500N1670 GMV-ND28T/C-T CM500N1660 GMV-ND45T/C-T CM500N1650 Part code Quantity Part code Quantity Electric Expand Valve Fitting...
  • Page 456 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND50T/C-T CM500N1640 Part code Quantity Terminal Board 42011106 Diversion Circle 26909400067 Centrifugal Fan 10429400004 Brushless DC Motor 1570410000702 Evaporator Assy 011001000239 Side Plate 1...
  • Page 457 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56T/C-T CM500N1630 Name of part GMV-ND63T/C-T CM500N1440 GMV-ND71T/C-T CM500N1370 Part code Quantity Electric Box Assy 100002066372 Main Board 300002060274 Filter Board 30221000021 Terminal Board 42200006000401 Terminal Board...
  • Page 458 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND80T/C-T,GMV-ND90T/C-,GMV-ND100T/C-T: For the following unit Unit Product Code GMV-ND80T/C-T CM500N1430 Name of part GMV-ND90T/C-T CM500N1420 GMV-ND100T/C-T CM500N1380 Part code Quantity Electric Box Assy 100002066372 Diversion Circle 26909400067 Centrifugal Fan 10429400004...
  • Page 459 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80T/C-T CM500N1430 Name of part GMV-ND90T/C-T CM500N1420 GMV-ND100T/C-T CM500N1380 Part code Quantity Drainage Pipe Sub-Assy 26909400055 Water Pump 43138000058 Corrugated Pipe 035030000007 Main Board 300002060274 Filter Board...
  • Page 460 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND112T/C-T CM500N1400 Name of part GMV-ND125T/C-T CM500N1410 GMV-ND140T/C-T CM500N1360 Part code Quantity Electric Box Assy 100002066372 Main Board 300002060274 Filter Board 30221000021 Terminal Board 42200006000401 Terminal Board...
  • Page 461 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND160T/C-T: For the following unit Unit Product Code Name of part GMV-ND160T/C-T CM500N1710 Part code Quantity Electric Box Assy 100002072281 Terminal Board 42200006005404 Terminal Board 42011106 Filter Board 30221000021 Main Board...
  • Page 462 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND160T/C-T CM500N1710 Part code Quantity Seal plate 01499400002 Liquid Level Switch 4502021601 Seat Board Sub-Assy 02229400011 Side Plate 1 01319400025 Side Plate 3...
  • Page 463 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND22T/C1-T CM500N1850 GMV-ND36T/C1-T CM500N1820 GMV-ND28T/C1-T CM500N1860 Part code Quantity Part code Quantity Electric Box Assy 100002071821...
  • Page 464 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND45T/C1-T, GMV-ND50T/C1-T: For the following unit Unit Product Code Name of part GMV-ND45T/C1-T CM500N1730 GMV-ND50T/C1-T CM500N1720 Part code Quantity Electric Box Assy 100002071821 Terminal Board 42000100000204 Main Board 300002061986 Terminal Board...
  • Page 465 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND45T/C1-T CM500N1730 GMV-ND50T/C1-T CM500N1720 Part code Quantity Water Pump 43138000058 Seat Board Sub-Assy 017080060112 Liquid Level Switch 4502021602 Side Plate 012010060371 Drain Hose...
  • Page 466 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND22T/D1-T CM500N2170 GMV-ND28T/D1-T CM500N2130 Name of part GMV-ND36T/D1-T CM500N2120 GMV-ND45T/D1-T CM500N2180 GMV-ND50T/D1-T CM500N2010 Part code Quantity Electric Box Assy 100002077709 Terminal Board 42200006005404 Main Board 300002062830...
  • Page 467 GREE Multi Variable Air Conditioners Indoor Units Exploded View Of GMV-ND56T/D1-T,GMV-ND63T/D1-T,GMV-ND71T/D1-T: For the following unit Unit Product Code GMV-ND56T/D1-T CM500N2100 Name of part GMV-ND63T/D1-T CM500N2160 GMV-ND71T/D1-T CM500N2030 Part code Quantity Electric Box Assy 017007063195 Terminal Board 42200006005404 Main Board 300002062830...
  • Page 468 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND56T/D1-T CM500N2100 Name of part GMV-ND63T/D1-T CM500N2160 GMV-ND71T/D1-T CM500N2030 Part code Quantity Water Pump 43138000058 Drainage Pipe Sub-assy 2690940005501 Liquid Level Switch 4502021603 Electric Expand Valve...
  • Page 469 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND80T/D1-T CM500N2110 Name of part GMV-ND90T/D1-T CM500N2190 GMV-ND100T/D1-T CM500N2140 GMV-ND112T/D1-T CM500N2020 Part code Quantity Electric Box Assy 100002077709 Terminal Board 42200006005404 Main Board 300002062830 Terminal Board...
  • Page 470 GREE Multi Variable Air Conditioners Indoor Units Exploded View Of GMV-ND125T/D1-T,GMV-ND140T/D1-T: For the following unit Unit Product Code Name of part GMV-ND125T/D1-T CM500N2150 GMV-ND140T/D1-T CM500N2040 Part code Quantity Electric Box Assy 100002077708 Terminal Board 42200006005404 Main Board 300002062748 Terminal Board...
  • Page 471: Heat Storage Module

    GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND125T/D1-T CM500N2150 GMV-ND140T/D1-T CM500N2040 Part code Quantity Body Installing Plate 01332701 Side Plate 012010061327 Drainage Pipe Sub-assy 26909400055 Water Pump 43138000058 Liquid Level Switch...
  • Page 472 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part XRZ180L/A-T CM810N2250 Part code Quantity Top Cover 012148060003 Base Frame 012252060002 Compressor Gasket 76713066 Heat Accumulator Sub-assy 32005002 Heat Accumulator Sub-assy 32005003 Strainer...
  • Page 473: High Static Pressure Duct Type Indoor Unit

    GREE Multi Variable Air Conditioners Indoor Units 5.19 High Static Pressure Duct Type Indoor Unit Exploded View GMV-ND22PHS/D-T, GMV-ND25PHS/D-T, GMV-ND28PHS/D-T, GMV-ND32PHS/D-T, GMV-ND36PHS/D-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22PHS/D-T CM810N2490 GMV-ND32PHS/D-T CM810N2500...
  • Page 474 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND22PHS/D-T CM810N2490 GMV-ND32PHS/D-T CM810N2500 Name of part GMV-ND25PHS/D-T CM810N2420 GMV-ND36PHS/D-T CM810N2410 GMV-ND28PHS/D-T CM810N2430 Part code Quantity Part code Quantity...
  • Page 475 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND40PHS/D-T, GMV-ND45PHS/D-T, GMV-ND50PHS/D-T: For the following unit Unit Product Code GMV-ND40PHS/D-T CM810N2440 Name of part GMV-ND45PHS/D-T CM810N2510 GMV-ND50PHS/D-T CM810N2400 Part code Quantity Filter Sub-Assy 111001000055 Return Air Frame Sub-Assy 017026000004...
  • Page 476 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code GMV-ND40PHS/D-T CM810N2440 Name of part GMV-ND45PHS/D-T CM810N2510 GMV-ND50PHS/D-T CM810N2400 Part code Quantity Temperature Sensor 3900005910 Temperature Sensor 390000592 Temperature Sensor 390000454 Display Board 30296000040 Air Outlet Frame Sub-assy...
  • Page 477 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND56PHS/D-T, GMV-ND63PHS/D-T, GMV-ND71PHS/D-T, GMV-ND80PHS/D-T: For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND56PHS/D-T CM810N2450 GMV-ND71PHS/D-T CM810N2460 GMV-ND63PHS/D-T CM810N2370 GMV-ND80PHS/D-T CM810N2360 Part code...
  • Page 478 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND56PHS/D-T CM810N2450 GMV-ND71PHS/D-T CM810N2460 GMV-ND63PHS/D-T CM810N2370 GMV-ND80PHS/D-T CM810N2360 Part code Quantity Part code Quantity Top Cover...
  • Page 479 GREE Multi Variable Air Conditioners Indoor Units Exploded View GMV-ND90PHS/D-T, GMV-ND100PHS/D-T, GMV-ND112PHS/D-T, GMV-ND125PHS/D-T, GMV-ND140PHS/D-T, GMV-ND160PHS/D-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND90PHS/D-T CM810N2470 GMV-ND140PHS/D-T CM810N2530 Name of part GMV-ND100PHS/D-T CM810N2520 GMV-ND160PHS/D-T CM810N2380...
  • Page 480 GREE Multi Variable Air Conditioners Indoor Units For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND90PHS/D-T CM810N2470 GMV-ND140PHS/D-T CM810N2530 Name of part GMV-ND100PHS/D-T CM810N2520 GMV-ND160PHS/D-T CM810N2380 GMV-ND112PHS/D-T CM810N2480 GMV-ND125PHS/D-T CM810N2390 Part code Quantity Part code...
  • Page 481 GREE Multi Variable Air Conditioners Indoor Units Exploded View of GMV-ND180PHS/D-T For the following unit Unit Product Code Name of part GMV-ND180PHS/D-T CM810N2240 Part code Quantity Filter Sub-Assy 111001000052 Return Air Frame Sub-Assy 017026000003 Centrifugal fan assy 000052000029 Propeller Housing(Upper)
  • Page 482 GREE Multi Variable Air Conditioners Indoor Units For the following unit Unit Product Code Name of part GMV-ND180PHS/D-T CM810N2240 Part code Quantity Main Board 30221000033 Reactor 43138000047 Main Board 300002061641 Terminal Board 42000100000101 Terminal Board 42200006000401 Electric Box Assy 100002070712...
  • Page 483 JF00302966...

This manual is also suitable for:

Gmv-nd140l/a-tGmv-nd56phs/a-tGmv-nd63phs/a-tGmv-nd71phs/a-tGmv-nd80phs/a-tGmv-nd90phs/a-t ... Show all

Table of Contents