5 Pipe Implementation
B23 When combustion air is taken from environment, exhaust gas transfer to outside with pipe.
C13 Combustion air and exhaust gas transfer to outside by pipes which their outlets are
interwoven or it can be transferred by separate pipes as maximum 50 cm distance between them.
C33 Vertical exit is made from roof by interwoven pipes
C43 Connection to common pipe outlet by interwoven pipes.
C53 Exit from wall or roof with separate pipes outlets at areas that have different pressure values.
While exiting from wall, it must not be exit from opposite walls.
C83 While fresh –air intake is being made from external environment by wall passing, exhaust gas
pipe can be directly taken out to outside or can be connected to common pipe system.