Electrical Hazards

Electrocution. Contact with bare wires,
terminals, and connections while generator
is running will result in death or serious injury.
Electrocution. Water contact with a power source,
if not avoided, will result in death or serious injury.
Electrocution. In the event of electrical accident,
immediately shut power OFF. Use non-conductive
implements to free victim from live conductor. Apply
first aid and get medical help. Failure to do so will
result in death or serious injury.
• The National Electric Code (NEC) requires
the frame and external electrically conduc-
tive parts of the generator be properly con-
nected to an approved earth ground. Local
electrical codes may also require proper
grounding of the generator. Consult with a
local electrician for grounding requirements
in the area.
• Use a ground fault circuit interrupter in any
damp or highly conductive area (such as
metal decking or steel work).
• Once generator has been started outside,
connect
electrical
cord(s) inside.

Fire Hazards

Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
Explosion and Fire. Do not overfill fuel tank. Fill to
1/2 inch from top of tank to allow for fuel expansion.
Overfilling may cause fuel to spill onto engine causing
fire or explosion, which will result in death or
serious injury.
WARNING
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
Fire risk. Fuel and vapors are extremely
flammable. Do not operate indoors. Doing so
could result in death, serious injury, or
property or equipment damage.
Owner's Manual for Portable Generator
DANGER
(000144)
DANGER
DANGER
loads
to
extension
DANGER
DANGER
(000142a)
WARNING
(000281)
(000104)
• Allow at least 5 feet of clearance on all
sides of the generator when operating to
prevent overheating and fire.
• Do not operate the generator if connected
electrical devices overheat, if electrical out-
put is lost, if engine or generator sparks, or
(000145)
if flames or smoke are observed while unit
is running.
• Keep a fire extinguisher near the generator
at all times.

Standards Index

1. National
(NFPA) 70: The NATIONAL ELECTRIC
CODE (NEC) available from www.nfpa.org
2. National
(NFPA) 5000: BUILDING CONSTRUC-
TION AND SAFETY CODE available from
www.nfpa.org
3. International Building Code available from
www.iccsafe.org
4. Agricultural Wiring Handbook available
from
Resource Council P.O. Box 309 Wilming-
ton, OH 45177-0309
5. ASAE EP-364.2 Installation and Mainte-
nance of Farm Standby Electric Power
available from www.asabe.org, American
Society of Agricultural & Biological Engi-
(000105)
neers 2950 Niles Road, St. Joseph, MI
49085
6. CSA C22.2 100-14 Electric motors and
generators for installation and use, in
accordance with the Rules of the Cana-
dian Electrical Code
7. ANSI/PGMA G300 Safety and Perfor-
(000166b)
mance of Portable Generators. Portable
Generator
www.pgmaonline.com
This list is not all inclusive. Check with the
Authority Having Jurisdiction (AHJ) for any
local codes or standards which may be appli-
cable to your jurisdiction.
WARNING
Explosion and fire risk. Do not smoke near unit.
Keep fire and spark away. Failure to do so could
result in death, serious injury, or property or
equipment damage.
WARNING
Explosion and Fire. Do not smoke while
refueling unit. Failure to do so could result in
death, serious injury, or property or equipment
damage.
Fire
Protection
Fire
Protection
www.rerc.org,
Manufacturer's Association,
(000282)
(000284a)
Association