Block Delay
It is a delay timer between barcode data output.
The feature is used to transfer continually with
shorter barcode data or multi-field scanning.
Response delay
If you use RTS/CTS or ACK/NAK for flow
control, you can decide how long your scanner
waits your computer to acknowledge the data
transmission.
Setting
Flow control
Inter-character
delay
*3AC*
Block delay
Response delay
(*) Default
Program
Option
None
RTS/CTS
Xon/Xoff
ACK/NAK
00-99 (msec)
00 to 99.
00-99 (100 msec)
30
Value
00*
01
02
03
00-99
00*
00 *
00-99
20*
Exit