Connection Connect the scanning gun to the special connector from the cable, inserted the other end of cable into the corresponding port of the PC. Please open the bar code configuration switch on the second page if the bar code configuration switch has been turned off Interface Mode This scanning gun supports three kinds of interface modes ,...
Page 3
Scan the following bar code can be configured as the USB turned to USB keyboard mode USB turning to RS232 Enable / Disable configuration code When the configuration code is open, you can scan all the configuration bar code for scanning gun configuration.
Page 4
Product default configuration Scan the following bar code can be returned to the factory default configuration. returned to the factory default configuration Product user configuration Scan the following bar code to save the current parameters of the product to the user configuration.
Page 5
Baud rate 19200 Baud rate 38400 Baud rate 57600 Baud rate 115200 Auto-sensing Scan Mode This product has auto-sensing scan mode. Scan the following bar code to configure the switch Disable Automatic Recognition Mode When the self sensing mode is configured to be closed, Decoded by the trigger of the scanning gun.Default configuration.
Disable auto-sensing scan Mode (Default) Enable Automatic Recognition Mode When the self sensing mode is configured to be open,The scanning gun can decode automatically by scanning lens before the bar code Enable auto-sensing scan Mode Screen Reading Mode When you turn on this mode, Scanners can be decoding the codes on phone or computer.
When focus mode is turn on, The scanner only identified the focus codes scanners lens covering, The default is turn off. Disable Focus Mode(Default) Enable focus mode Suffix Setting Cancel / enter Tab...
Page 9
Enable Disable ( default mode) Successful decoding prompt tone ON-OFF On (default) Successful decoding prompt tone GHZ(volume)
Page 10
Volume-low Volume-middle(default) Volume-high Successful decoding prompt tone time LONG(default) Short Error Warming Volume-low(default) Volume-middle...
Page 11
Volume-high LED Indicating Lamp Successful decoding LED light off Successful decoding LED light on...
Page 12
Same barcode Scanning interval Setting By default,the interval time between first scanning and second scanning for same bar code is 700ms. To avoid unwanted repeat scanning, you can scan the configuration bar code to set the interval time. 500ms 700ms (default) USB keyboard transfer speed The speed of transferring data using USB connecting mode.
Slow(default) Middle Fast Bar code selection Turn on/off all kinds of bar code reading Turn on the mode of all kinds of bar code may slow the scanning decoding speed,you can select some bar code you nee. The mode of all kinds of bar code is on by default.
Data Matrix Enable Data Matrix Disable Data Matrix Aztec Code Enable Aztec Disable Aztec...
Page 31
Warning When the data transfer abnormal, Scan ner will Send out a sound for four consecutive sound tones, Please make sure cable is normal under this issue. Tips * Make sure get one nice decoding result, Laser beam need aim at code but any direction.
Page 32
Safety The Laser beam will be strong when you scanning, To avoid discomfort or harm, Don’t staring into laser beam.