In this chapter the basic structure of the devices Filter for mains applications BFN and
of the type codes on the devices.
No filters are required for the operation of the power converter.
NOTICE!
m The mains filters may not be used as a motor filter at the converter output.
m Mains filters BFN-3-1-XXX-XXX may not be used with active mains inverters. For
TN-TT-systems
In order to comply with the limit values of the EMC-standards, the use of Baumüller mains
see
ZSystem
filters BFN-3-1-XXX-X01 is required.
types–
on page 15
NOTICE!
Baumüller mains filters BFN-3-1-XXX-X01 can be used in
they can not be used in
In order to allow the compliance with the limit values for the conducted interferences („ex-
ternal" second environment - EN 61800-3, table 9) in low-impedance grounded low-volt-
age systems use Baumüller mains filters combined with Baumüller converters, Baumüller
motor cables and Baumüller motors. If all installation- and EMC-notes of this Handbook
are complied with, it is assumed that the interference-suppressed drive accords to the
protection requirements of the EMC-Directive 89/336/EWG and of the EMC-act (EMVG).
D
ESCRIPTION OF THE DEVICES
4
this converter type special filters are available, refer to
verter–
from page 22.
m Grounded industrial systems of hard or low impedance
m Grounded industrial systems of insulated and high impedance.
m Grounded wye-supply systems
m Grounded industrial systems of hard- or low impedance
Instruction handbook Mains filters BFN
Document No.: 5.09010.03
ZFilters for active mains in-
33
of 70