3.4
Electrical data
3.4.2

Filters for IT-systems

BFN 3-1-... -002
Max. 
power supply
Rated current 
(at T
= 50 °C)
B
Peak current 
(at T
= 50 °C)
B
Test voltage
Connection
Power loss (typical)
Protection class
BFN 3-1-... -102
Max. 
power supply
Rated current 
(at T
= 50 °C)
B
Peak current 
(at T
= 50 °C)
B
Test voltage
Connection
Power loss (typical)
Protection class
32
Instruction handbook Mains filters BFN
Document No.: 5.09010.03
of 70
150
0250
0320
3 x 480 V
150 A
250 A
320 A
1,5 x I
Cable - Cable: 2150 V
Cable - Cabinet: 2700 V
Bolt M10
Rail with hole
 11mm
PE: Bolt M12
30 W
60 W
40 W
0320
3 x 480 V
250 A
320 A
1,5 x I
2,5 x I
Cable - Cable: 2280 V
Cable - Cabinet: 2690 V
Rail with hole 11mm
PE: Bolt M10
31 W
0400
+10 %, 50/60 Hz
AC
400 A
4 x I
at switch-on
N
for < 1 min / once per hour
N
/ 2 s
DC
/ 2 s
DC
Rail with hole
 11mm
PE: Bolt M12
50 W
IP 00
0400
0600
+10 %, 50/60 Hz
AC
400 A
for < 3 min per hour
N
or
for 30 s per hour
N
/ 2 s
DC
/ 2 s
DC
48 W
84 W
IP 00
Baumüller Nürnberg GmbH
0600
600 A
Rail with hole
 11mm
PE: Bolt M12
65 W
1000
1000 A
Rail with hole
 14mm
PE: Bolt M12