Maintenance - Honda EU65is Owner's Manual

Hide thumbs Also See for EU65is:
Table of Contents

Advertisement

07/09/15 12:29:09 32Z25610_044
8.

MAINTENANCE

The purpose of the maintenance and adjustment schedule is to keep
the generator in the best operating condition.
Inspect or service as scheduled in the table below.
Make sure the engine is off before you begin any maintenance or
repairs. This will eliminate several potential hazards:
Carbon monoxide poisoning from engine exhaust. Be sure there is
adequate ventilation whenever you operate the engine.
Burns from hot parts. Let the engine and exhaust system cool
before touching.
Injury from moving parts. Do not run the engine unless instructed
to do so.
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Be careful not to touch the muffler
while it is hot. Let the engine cool before maintenance.
Use genuine Honda parts or their equivalent. The use of replacement
parts which are not of equivalent quality may damage the generator.
Maintenance Schedule
REGULAR SERVICE PERIOD (3)
Item
Performed at every indicated
month or operating hour interval,
whichever comes first.
Engine oil
Air cleaner
Sediment cup
Spark plug
Spark arrester
Valve Clearance
Combustion
chamber
Fuel tank & filter
Fuel line
(1)
Service more frequently when used in dusty areas.
(2)
These items should be serviced by your servicing dealer, unless you have the proper tools
and are mechanically proficient. Refer to Honda shop manual for service procedures.
(3)
For commercial use, log hours of operation to determine proper maintenance intervals.
40
Each use
Check level
Change
Check
Clean
Clean
Check-adjust
Replace
Clean
Check-adjust
Clean
Clean
Check
Every 2 years (Replace if necessary) (2)
First
Every
Every
month
3 months
6 months
or
or
or
20 hrs.
50 hrs.
100 hrs.
(1)
After every 500 hrs. (2)
(2)
Every
year
or
300 hrs.
(2)