1.
Remove the screws from the back of the valve and
pull the front cover
2.
Remove all connections from the circuit board
3.
Remove the four screws from the
circuit board and pull it out
REPLACE
MICROSWITCHES
1.
4X Screws
3.
1.
Remove Screws from the back of the valve
and pull the cover
2.
Remove all connections from the circuit board
3.
Remove the two screws from the microswitch
4.
Replace the microswitch, connections and cover
AFTER SERVICING
1.
Reconnect drain line
2.
Return bypass or inlet valve to normal in service
position. Water pressure will automatically build
in the refiner
3.
Check for leaks at all sealed areas. Check drain seal
with the control in the backwash position
4.
Plug electrical cord into outlet
5.
Set Time of Day and cycle the control valve manually to
assure proper function. Make sure control valve is
returned to the In Service position
NOTE
Be sure to shut off any bypass line.