Maintenance Instructions And Schedule - NUVIA Signature NW-SIG-948-1.0 Owner's Manual

Dynamic regeneration
Table of Contents

Advertisement

MAINTENANCE INSTRUCTIONS CONTINUED FROM PAGE 19

MAINTENANCE INSTRUCTIONS AND SCHEDULE

CHECKING THE SODIUM LEVEL
Check the sodium level monthly. Remove the lid from the brine tank, make sure SODIUM level is always above the brine level.
ADD SODIUM TO THE BRINE TANK/CABINET
Put 88 lbs of crystal water refiner sodium in the brine tank. The unit will automatically fill the water to the correct level when it
regenerates. Use only clean sodium labeled for water conditioner use, such as crystal, pellet, nugget, button or solar. The use of rock
SODIUM is discouraged because it contains insoluble silt and sand which build up in the brine tank and can cause problems with the
system's operation. Add the sodium directly to the tank, filling no higher than the top of the brine well.
NOTE: THE WATER LEVEL SHOULD BE BELOW THE SODIUM LEVEL ALL THE TIME
Sodium
Water
IMPORTANT WARRANTY AND MAINTENANCE INFORMATION
PLEASE HAVE THE INFORMATION BELOW FILLED OUT AND AVAILABLE WHEN CALLING IN FOR PARTS OR
WARRANTY:
Model number:
Serial number:
Valve Serial number:
Date installed:
ADDITIONAL NOTES:
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
20
REPLACING MEDIA BED
Frequency of replacing bed is determined
by water quality and usage. If you start
getting chlorine smell or grey / black
coloration of the water from time to time
contact Nuvia® Water Technologies with
your model number to order replacement
media.