PREPARATIONS

1.
Media Installation (When Necessary). Models larger than 1.5 CF of media are shipped with
separate media in pails or boxes. Models lower than 1.5 CF of media come loaded with media
and this step can be skipped for new installation.
a
The riser
(distributor)
remains inside
the tank seated in
the depression at
the bottom
a.
Temporarily plug the open end of the riser tube
to ensure that no media or gravel falls down into
the
distribution. The riser (distributor) remains inside
the tank seated in the depression at the bottom.
Plug tube with a tape. Remove after media is
loaded.
LOCATE WATER CONDITIONING EQUIPMENT CORRECTLY
Select the location of your filter tank with care. Various conditions which contribute to proper
location are as follows:
1.
Locate as close as possible to the water supply source.
2.
Locate as close as possible to a floor or laundry tub drain.
3.
Locate in correct relationship to other water conditioning equipment (see Fig. 1, 2, 3 or 4, Page 11
and 12). if closer than 10 feet please install check valve in accordance with local plumbing codes.
4.
Conditioners should be located in the supply line before the water heater. Temperatures above
110°F (43°C ) will cause damage to conditioners.
5.
Do not install a filter or filter in a location where freezing temperatures occur. Freezing may cause
permanent damage to this type of equipment and will void the factory warranty.
6.
Allow sufficient space around the unit for easy servicing.
7.
Keep the filter out of direct sunlight. The sun's heat may soften and distort plastic parts.
12
b
Plug the Riser
Tube
b.
Fill support bed first. The
Make sure both
brass and plastic
nuts are tightened
well
media will not always spill
down inside the tank and may
need to be swept inside.
The large funnel (sold
separately makes filling the
tank easier and neater. (Or
an empty 1 gallon or 4 liter
container with the bottom cut
out makes a good funnel.)
Delete?
CAUTION!
The unit should be
depressurized before
installing or replacing media
NOTE
Never make a direct
connection into a waste
drain. A physical air
gap of at least 1.5"
should be used to
avoid bacteria and
wastewater travelling
back through the drain
line into the refiner.
NOTE
The unit is not ready for
service until you
complete the start-up
instructions, page 15.