System Example When Operating The Srp-X700P From The Remote Parallel Terminal - Sony SRP-X700P Operating Instructions Manual

Digital powered mixer
Hide thumbs Also See for SRP-X700P:
Table of Contents

Advertisement

System Configuration
System example when operating the SRP-X700P from the REMOTE
PARALLEL terminal
The REMOTE PARALLEL terminal of the SRP-X700P is shipped from the factory with the default setting on the premise of the external
operation panel as described below.
Camera
VHS
DV
START
Stand
FINISH
EMG STOP
START button (SCENE No. 1 recall): Sets OUTPUT7 and OUTPUT9 to ON to lower the screen, to close the curtain, to darken the illumination and to start presentation.
FINISH button (SCENE No. 2 recall): Sets OUTPUT8 and OUTPUT10 to ON to raise the screen, to open the curtain, to turn on the illumination and to end the presentation.
EMG STOP button (SCENE No. 3 recall): Sets OUTPUT7 through OUTPUT10 to OFF to stop moving the screen and the curtain, and to turn on the illumination.
Selector block: Switches the LINE4 INPUT terminals A through F.
MIC volume control: Controls the microphone sound volume.
AV volume control: Controls sound volume of the AV equipment.
SRP-X700P REMOTE PARALLEL terminal
D-sub 25-pin connector
Pin No. Terminal name
1
GND
GND
2
INPUT1
VHS selection
3
INPUT2
DV selection
4
INPUT3
Camera selection
5
INPUT4
DVD selection
6
INPUT5
PC1 selection
7
INPUT6
PC2 selection
8
INPUT7
START
9
INPUT8
FINISH
10
INPUT9
EMG STOP
11
INPUT10
Microphone sound volume
12
INPUT11
AV equipment sound volume
13
INPUT12
———
14
GND
GND
15
OUTPUT1
VHS selection tally
16
OUTPUT2
DV selection tally
17
OUTPUT3
Camera selection tally
18
OUTPUT4
DVD selection tally
19
OUTPUT5
PC1 selection tally
PC2 selection tally
20
OUTPUT6
21
OUTPUT7
Lowers the screen.
22
OUTPUT8
Raises the screen.
23
OUTPUT9
Close the curtain/turn off illumination.
24
OUTPUT10
Open the curtain/turn on illumination.
25
GND
GND
Precaution on the environment interface box specifications
• The REMOTE PARALLEL output terminal provides the open-collector output of
alternate operation. It means that the output terminal keeps outputting the ON signal
after an output command is issued to operate the environment equipment by using
scene recall and others, regardless of the operating condition of the environment
equipment. The environment equipment motors should be stopped when you want to
stop raising or lowering the screen or curtain, by the Interface Box.
• The Emergency Stop signal turns off the output signals at the OUTPUT7 to
OUTPUT10 terminals.
Please create an Interface Box that stops moving the screen and the curtain, and turns
on illumination when the output terminals are turned off.
Example of controlling the environment equipment by scene recall operation
OUTPUT 7,9
Terminal
name
OUTPUT 8,10
Screen
Curtain
Illumination
Raise
Open
Environment
Stop
equipment
Lower
Close
14
DVD
PC1
PC2
MIC
Function name
OFF
ON
OFF
ON
Bright
Bright
Dark
Turning on
START
(SCENE No. 1 recall)
the power
AV
External operation panel
VHS VCR selector button
DV VCR selector button
Picture presentation camera selector button
DVD selector button
PC1 selector button
PC2 selector button
START (presentation start) button
FINISH (presentation finish) button
Emergency stop button
Microphone sound volume control (10kΩ B-curve)
AV equipment sound volume control (10kΩ B-curve)
LED
FINISH
START
(SCENE No. 2 recall)
(SCENE No. 1 recall)
40mA or less
VHS VCR selection LED
DV VCR selection LED
Picture presentation camera selection LED
DVD selection LED
PC1 selection LED
PC2 selection LED
DC 24V or less
Lowers the screen.
Raises the screen.
interface box
Closes the curtain.
Opens the curtain.
interface box
Turns off illumination.
Illumination
Turns on illumination.
interface box
EMG STOP
(SCENE No. 3 recall)
Screen
Curtain

Advertisement

Table of Contents
loading

Table of Contents