Remote Parallel Terminal - Sony SRP-X700P Operating Instructions Manual

Digital powered mixer
Hide thumbs Also See for SRP-X700P:
Table of Contents

Advertisement

How to Control the SRP-X700P from External Equipment

REMOTE PARALLEL Terminal

The REMOTE PARALLEL terminal enables the SRP-X700P to be
remotely controlled with a simple circuit connected externally to
this terminal.
Terminal shape
: D-sub 25-pin, female
Recommended cable
: Multi-core shielded cable for data
Cable length
: 50 m or less
INPUT terminal
You can set the functions of the respective terminals from the
PARALLEL INPUT FUNCTION setup box in the REMOTE
screen of the supplied SRP-X700P Manager software.
All faders and sound volume controls can be controlled from a
remote location by connecting a variable resistor as shown, in the
range of 0 to – ∞ dB.
You can perform the following operations by adding a make contact.
• Input selection of LINE 4 system
• Muting
• Scene recall
• Sound volume adjustment (Up/Down)
• Controlling the AV equipment connected to the CONTROL S
terminal
• Power-ON/STANDBY selection of a projector
OUTPUT terminal
The turning ON conditions of the respective pins of the OUTPUT
terminal can be set from the following.
• Input selector state of LINE 4 system
• Turning ON the OVER and – ∞ indicators
• Turning ON the scene recall button
• Generation of the Power-ON/STANDBY command of a
projector
You can select the ON conditions from the PARALLEL OUTPUT
FUNCTION setup box on the REMOTE screen of the supplied
SRP-X700P Manager software.
10
communication
<Example of input circuit>
SRP-X700P
Input terminal
(No. 2 to No. 13)
GND
(Nos. 1, 14 and 25)
10 kΩ
Curve-B variable
resistor
SRP-X700P
Input terminal
(No. 2 to No. 13)
GND
(Nos. 1, 14 and 25)
<Example of output circuit>
40 mA MAX
SRP-X700P
N
Output terminal
(No. 15 to No. 24)
GND
(Nos. 1, 14 and 25)
Note
• Do not apply any reverse voltage across the output terminal.
• Do not connect the shield cable of the REMOTE wire and the
GND wire to the terminal table or the like. It can cause
malfunction and noise.
• Install the REMOTE cable away from the dimmer, motor and
others.
(D-sub 25-pin, female)
Pin No.
Function
1
GND
0 dB
2
INPUT1
3
INPUT2
–∞ dB
4
INPUT3
5
INPUT4
6
INPUT5
7
INPUT6
8
INPUT7
9
INPUT8
10
INPUT9
11
INPUT10
12
INPUT11
13
INPUT12
14
GND
15
OUTPUT1
16
OUTPUT2
17
OUTPUT3
18
OUTPUT4
LED
19
OUTPUT5
24 V
20
OUTPUT6
MAX
21
OUTPUT7
22
OUTPUT8
23
OUTPUT9
24
OUTPUT10
25
GND