Example of a circuit connection to the
output pins of the REMOTE PARALLEL
connector
Output pins (No.15 to 24)
GND pins (No. 1,
12 to 14, 25)
The trigger for turning on each pin of the REMOTE
PARALLEL connector can be selected from the
following:
• Status of the AV/RGB SELECT buttons
• Turning on the MASTER MUTING indicator
• The status of scene recall function
• Command to turn on or change to standby status the
projector or the monitor
• Status of the MASTER control and REMOTE FADER
on the SRP-X500P Manager (maximum/minimum/
muted)
• Muting via control from an emergency broadcast system
The trigger for each pin can be selected in the REMOTE
PARALLEL section of the REMOTE
PARALLEL/PROJECTOR CONTROL screen of the
SRP-X500P Manager software.
Notes
• Do not apply a reverse voltage across the output pins.
• Do not connect the shield of the remote wire or the
ground wire to a relay table, etc. This can cause the
device to malfunction and noise.
• Keep the remote wire away from dimmers or motors.
Example of a custom-made
operation panel connection to the
REMOTE PARALLEL connector
The SRP-X500P is factory set to connect a custom-made
operation panel with the following buttons: