Gas burner ignition fault
Error
Gas Ignition
Reset the igniter
Dx
°C
Reset Ignitor
Fault with the heating system
Problem
Fault with the heating system
7
5
Page
(only for machines using gas heating)
(only for machines using gas heating)
2.5m/min 000
STOP
5. Operating incidents
"Gas ignition fault" message
(only on gas-heated machines).
The screen will alternately display this fl ashing
message and the service screen. This means that the
lighting of the gas burners has been requested.
If this message has been displayed over 30 seconds,
the gas burner is not ignited. The heating system falls
into safety state and heating is cut off. Try again and
follow the starting procedure.
Press any key to display the following menu.
After an additional failure, please check the gas
heating running. If the fault remains, consult your
after-sales service.
Message: "Reset igniter"
The message on the screen will then ask you if you
wish to reset the igniter.
Press on one of the two buttons on the left to restart
the gas igniter.
Press the "STOP" button to stop the machine.
Message: "Problem - fault with the heating
system".
The screen appears if, after a certain time
(approximately 20 minutes) the cylinder temperature
remains below 100°C.
Try to restart the machine.
If the problem continues, please consult your after-
sales service department.