Summary of Contents for Dover Wilden Advanced Series
Page 1
T1510 E n g i n e e r i n g ™ O p e r a t i o n & Advanced Series METAL Pumps M a i n t e n a n c e A d v a n c e y o u r p r o c e s s WIL-11142-E-03 REPLACES WIL-11142-E-02...
S e c t i o n 1 C A U T I O N S — R E A D F I R S T ! CAUTION: Do not apply compressed air to the CAUTION: Pumps should be thoroughly fl ushed exhaust port —...
S e c t i o n 2 W I L D E N P U M P D E S I G N A T I O N S Y S T E M T1510 ADVANCED™ LEGEND T1510 / XXXXX / X XX / XX / X XX / XXXX METAL GASKETS...
Page 5
S e c t i o n 3 H O W I T W O R K S — P U M P The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show fl ow pattern through the pump upon its initial stroke.
S e c t i o n 5 A P E R F O R M A N C E T1510 ADVANCED™ METAL RUBBER-FITTED Height .........754 mm (29.7”) Width ........874 mm (34.4”) Depth ........427 mm (16.8”) Ship Weight ..Aluminum 84 kg (185 lbs.) Ductile Iron 162 kg (357 lbs.) Air Inlet ........
Page 8
S e c t i o n 6 S U G G E S T E D I N S T A L L A T I O N Wilden pumps are designed to meet the performance MUFFLER: Sound levels are reduced below OSHA requirements of even the most demanding pumping specifi...
Page 9
S U G G E S T E D I N S T A L L A T I O N NOTE: The fl uid inlet to the Brahma Advanced™ pump is located at the top and the fl uid discharge is located at the bottom of the pump.
Page 10
S U G G E S T E D O P E R A T I O N & M A I N T E N A N C E OPERATION: The Turbo-Flo™ pump is is a non lube free Turbo-Flo V™...
S e c t i o n 7 P U M P D I S A S S E M B L Y CAUTION: Before any maintenance or repair is attempted, the compressed air line T O O L S R E Q U I R E D : to the pump should be disconnected and all air pressure allowed to bleed from the •...
Page 12
P U M P D I S A S S E M B L Y Step 4 Step 5 Step 6 Next, remove the inlet elbow from Next, remove the fl ap valve assembly Using a 7/16" wrench, remove the the liquid chamber.
Page 13
P U M P D I S A S S E M B L Y Step 10 Step 11 Step 12 Next, remove the remaining inlet Using a 3/4" wrench, remove the Next, remove the discharge elbow fl ap valve assembly from the inlet fasteners that connect the discharge from the liquid chamber.
Page 14
P U M P D I S A S S E M B L Y Step 16 Step 17 Step 18 Remove the remaining discharge Now the remaining fl ap valve Next, remove the threaded studs elbow from the liquid chamber. assembly can be removed.
Page 15
P U M P D I S A S S E M B L Y Step 22 Step 23 Step 24 With the pump still positioned on its To remove the diaphragm assembly With the lock nut removed, the side, use a 3/4" wrench to remove from the pump, remove the lock nut diaphragm assembly can now be the fasteners and liquid chamber.
Page 16
P U M P D I S A S S E M B L Y Step 28 Step 29 Step 30 With the liquid chamber fasteners Using a 7/32" hex key wrench and a Next, list the air chamber away removed, the center section can 9/16"...
Page 17
A I R V A L V E / C E N T E R S E C T I O N D I S A S S E M B L Y The air valve assembly consists of both the air valve body and piston and the center block.
Page 18
A I R V A L V E / C E N T E R S E C T I O N D I S A S S E M B L Y Small nicks can usually be dressed out and the piston returned to service.
Page 19
R E A S S E M B L Y H I N T S & T I P S ASSEMBLY: INSTALLATION Upon performing applicable maintenance to the air The following tools can be used to aid in the installation distribution system, the pump can now be reassembled.
S e c t i o n 8 E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL W e t t e d P a t h E X P L O D E D V I E W DRAWING B DRAWING A...
Page 21
E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL W e t t e d P a t h P A R T S L I S T I N G T1510/ T1510/...
E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL C e n t e r S e c t i o n A s s e m b l y E X P L O D E D V I E W DRAWING A ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN CONVERSION KIT (see section 9).
Page 23
E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL C e n t e r S e c t i o n A s s e m b l y P A R T S L I S T I N G T1510/ T1510/...
E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL F l a p A s s e m b l i e s E X P L O D E D V I E W DRAWING B DRAWING C...
Page 25
E X P L O D E D V I E W A N D P A R T S L I S T I N G T1510 ADVANCED METAL F l a p A s s e m b l i e s P A R T S L I S T I N G T1510/ T1510/...
S e c t i o n 9 E L A S T O M E R O P T I O N S & C O N V E R S I O N K I T T1510 ADVANCED METAL Diaphragm, Flap GASKET,...
Page 27
W A R R A N T Y Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation. Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first.
Need help?
Do you have a question about the Wilden Advanced Series and is the answer not in the manual?