Wiring The Transmitter - Wall Mount; Wiring The Transmitter - Pole Mount; Wiring - SECO-LARM ENFORCER E-964-Q660Q Manual

Multi-frequency quad photobeam detectors, 660 ft. (200m) outdoors, 1320 ft. (400m)indoors, 495 ft. (150m) outdoors, 990 ft. (300m) indoors, 330 ft. (100m) outdoors, 660 ft. (200m) indoors, 165 ft. ( 50m) outdoors, 330 ft. (100m) indoors
Table of Contents

Advertisement

ENFORCER Quad-Photobeam Detectors
Wiring the Transmitter – Wall Mount
1. Remove the cover. Remove the screw under the
lens unit in order to detach the mounting plate.
See fig. 4.
2. If the sensor wiring comes from inside the wall –
Break a hole in the mounting plate's rubber
grommet, and pull the cable through the
grommet's hole. Then run the cable through the
hole near the bottom of the sensor unit so it
comes out the front. Using two of the included
mounting screws, attach the mounting plate to
the wall. Then reattach the sensor unit to the
mounting plate, connect the wires, and snap on
the cover. See fig. 5.
3. If the sensor wiring is run along the surface of the
wall – There are four plastic knockouts on the
back of the sensor unit, two on top and two on
bottom. Break out the appropriate knockout, and
pull the wiring through the knockout. Then run the
wiring through the hole near the bottom of the
sensor unit so it comes out the front. Using two of
the included mounting screws, attach the
mounting plate to the wall. Then reattach the
sensor unit to the mounting plate, connect the
wires, and snap on the cover. See fig. 6.
Wiring the Transmitter
– Pole Mount
(NOTE – Pole mounting bracket included.)
1. Remove the cover. Remove the screw under
the lens unit in order to detach the mounting
plate. See fig. 4.
2. Break a hole in the mounting plate's rubber
grommet, and pull the cable through the
grommet's hole. Then run the cable through
the hole near the bottom of the sensor unit so
it comes out the front. Use the included
mounting bracket to mount to the pole. Then
reattach the sensor unit to the mounting plate,
connect the wires, and snap on the cover.
See fig. 7.
Wiring (fig. 8)
1. Screw the wires tightly to avoid slipping off the
terminals, but not so tight that they break.
2. Screws on terminals which are not used
should be tightened.
3. Grounding may be necessary, depending on
the location.
6
Fig. 4:
Remove the
Transmitter
cover
Fig. 5:
Wall Mount,
Wire from
Inside Wall
Fig. 6:
Wall Mount,
Wire Runs
Along Wall
Fig. 7:
Pole Mount
– or –
SECO-LARM
®
U.S.A.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents