Service Menu For Rtm 430 - Bosch RTM 430 Repair Instructions

Exhaust-gas opacity module
Hide thumbs Also See for RTM 430:
Table of Contents

Advertisement

Available languages

Available languages

6.

Service menu for RTM 430

i The chapters described below all relate to the service program 1 687 000 661
(service software RTM). The interconnecting cable 1 684 463 389 is required for
connecting the equipment.
! Always follow the information on screen.
Connection of the equipment
PC /
COM1
Laptop
EAM
RTM
(VSM)
Power
supply
RTM
unit
The software version, the checksum, the RTM operating mode and the DIP switch
settings are displayed in the menu items after you enter the Service menu.
For example:
i You may see message Error in the RTM mode field after the self-test of the RTM
430. In this case, read out the contents of the error memory in the Read errors
menu. After reading out the contents of the error memory, the RTM 430 is set to
Standby mode and the errors can be processed if necessary.
1 684 463 389
1 684 465 378
RTM 430
459601/5CK
59