Digital Keypad Operation; Description Of The Digital Keypad; Operation Panel Schematic Diagram; Explanation Of Screen Display - Fuling Inverter DZB200 Series User Manual

High-performance general-purpose inverter. open-loop vector control inverter
Hide thumbs Also See for DZB200 Series:
Table of Contents

Advertisement

 DZB Series
5 / 1 4 / 2 0 1 8
Chapter 4 Digital Keypad Operation
4 . 1

Description of the Digital Keypad

● Digital Keypad Parts and Functions
This digital keypad module includes two parts: display panel and a keypad. The display panel
allows the user to program the AC drive, as well as view the different operating parameters. The
keypad is the user interface to theAC mot or drive. Refer to the following figure for a description
of the different parts.
RUN STOP JOG
Function indicator
FWD
REV
Forward / Reverse key
JOG
Jog key
Run key
Fig. 4-1 Operation Panel Schematic Diagram
Key
Program / Reset
PRGM
RESET
First-stage menu entry or exit.
Function / Data
Displays information on theAC drive status such as the reference frequency,output
FUNC
frequency, or output current in the normal mode. While the drive is in the Program Mode,
DATA
press this key once to display the current paramet ers.
After changing the parameters, press th is key again to store the new parameters.
Forward / Reverse
Used to toggle between forward and reverse operation.
FW D
RE V
Pressing this key will cause the motor to ramp down to 0 Hz and then ramp up to the preset
speed in the opposite direction.
JOG/ 
JOG
Used to start the AC drive, then run at the jog frequency.
When modify parameter, can select modified bit of the parameter.
h t t p : / / s l i d e p d f . c o m / r e a d e r / f u l l / f u l i n g - i n v e r t e r - u s e r - m a n u a l

Chapter 4 Operation and Display

FWD
REV
Digital display
Up and down keys
PRGM
RESET
Program key
FUNC
DATA
Function / Data key
RUN
STOP
Stop / Reset key
Description
- 1 7 -
 DZB Series
F u l i n g I n v e r t e r U s e r M a n u a l - s l i d e p d f . c o m
Run
Used tos tart theAC drive operation.
RUN
This key has no effect when the drive is set to terminal run.
Stop
STOP
Used tos top theAC drive operation.
If the AC drive has stopped due to a fault, press this button to reset the drive.
Up / Down
Press the "Up" or "Down" button to change parameter settings .
These keys may also be used to scroll through different operating val ues or parameters.

Explanation of Screen Display

1.
Explanation of Displayed Messages on Running status r
Displayed
Symbol
Chapter 4 Operation and Display
( efer to F3.05):
Displayed Message
Operation
Press
"
"
key
Setting frequency
QUICK
FUNC
DATA
JOG
"
"
Press
key
Running frequency
QUICK
FUNC
DATA
JOG
Press
"
"
key
Output current
QUICK
FUNC
DATA
JOG
"
"
Press
key
Output voltage
FUNC
QUICK
DATA
JOG
"
"
Press
key
Running speed
FUNC
QUICK
DATA
JOG
"
"
Press
key
Output power
QUICK
FUNC
DATA
JOG
Press
"
"
key
Output torque
FUNC
QUICK
DATA
JOG
"
"
Press
key
DC bus voltage
FUNC
QUICK
DATA
JOG
"
"
Press
key
PID setpoint
QUICK
FUNC
DATA
JOG
"
"
Press
key
PID feedback 
FUNC
QUICK
DATA
JOG
Press
"
"
key
Input terminal status
QUICK
FUNC
DATA
JOG
"
"
Press
key
Output terminal status
QUICK
FUNC
DATA
JOG
"
"
Press
key
VI value
FUNC
QUICK
DATA
JOG
"
"
Press
key
CI value
QUICK
FUNC
DATA
JOG
Current segment of 
"
"
Press
key
FUNC
QUICK
multi-speed control
DATA
JOG
- 1 8 -
1 2 / 5 4

Advertisement

Table of Contents
loading

Table of Contents