s e c t i o n 3
A C P O W E R C O N N E C T I O N
The Exterior 600 is available with a power supply for operation at 200/230/245 V, 50 Hz and 208/227 V, 60 Hz; and
with a special transformer for operation at 277 V, 60 Hz. This section describes how to tap the power supply for the
local AC voltage and frequency and how to connect the Exterior 600 to AC power.
Do not connect the Exterior 600 to an electrical dimmer system: doing so can damage the electronics.
Warning
Ta p p i n g t h e p o w e r s u p p l y
Ve r i f y s e t t i n g s
The voltage and frequency settings must match the local AC power supply! The factory-set power supply tappings are
printed on the serial number label on the back plate. Operating at the incorrect power setting can result in poor light
output, greatly reduced lamp life, overheating and damage to the fixture. If the setting does not match your local AC
voltage and frequency, then the power supply must be retapped as described below.
C h a n g i n g v o l t a g e a n d f r e q u e n c y s e t t i n g s , s t a n d a r d p o w e r s u p p l y
Local AC Supply
Frequency
50 Hz
60 HZ
The fixture is supplied with a weatherproof power cable. However, note that if
there is a breach or cut at any point along the power cable (for example at a
connection point), and if this is exposed to water, moisture can be drawn up
the inside of the cables due to the vacuum effect from the heat generated
during operation. When installing the product outdoors, always ensure that
the fixture is protected from water ingression from inside its power cable by:
• Protecting the connectors on the power cables in a weatherproof housing, or a
weatherproof electrical junction box, or
• Using IP65 rated cord caps, or
• Replacing the supplied cable with one that connects directly inside the fixture.
Check voltage and frequency settings before applying power.
Voltage
200-210 V
210-220 V
220-235 V
235-240 V
240-260 V
200-217 V
217-240 V
Disconnect the fixture from AC power before removing any cover.

AC Power Connection

I M P O R T A N T !
Transformer
Setting
Terminal
210 V
4
210 V
4
230 V
6
230 V
6
250 V
8
210 V
4
230 V
6
W A R N I N G !
Ballast
Setting
Terminal
200 V / 50 Hz
7
230 V / 50 Hz
10
230 V / 50 Hz
10
245 V / 50 Hz
12
245 V / 50 Hz
12
208 V / 60 Hz
4
227 V / 60 Hz
7
7