Running A Test Sequence With The Mpbb1; Calibrating Effects With The Mpbb1; Manual Control; Installing Software - Martin Professional Exterior 600 User Manual

Table of Contents

Advertisement

R u n n i n g a t e s t s e q u e n c e w i t h t h e M P B B 1
The test sequence allows you to test the fixture without a controller.
1.
Select
2.
Select the mode,
3.
Select single-fixture (
fixture mode, scroll to the address of the fixture to test. Press [Enter].
4.
Navigate to
C a l i b r a t i n g e f f e c t s w i t h t h e M P B B 1
The calibration menu allows you to adjust the effects for total uniformity between fixtures: it is not a substitute for
mechanical adjustment, which shall only be performed by a qualified technician.
1.
Select
2.
Select the mode,
3.
Select
4.
Navigate to
5.
Select effect to calibrate: dimmer (
Press [Enter].
6.
Adjust from 1 to 255. Press [Enter] to save the calibration.
M a n u a l c o n t r o l
The adjustment menu (AdJ) provides manual control for making mechanical adjustments and is for service techni-
cians. The menu provides functions to reset the fixture (
all effects to their
I n s t a l l i n g s o f t w a r e
The latest control software for the Exterior 600 is available from your Martin dealer and the Martin web site at http://
www.martin.dk.
Software is uploaded to the Exterior 600 using an uploader such as the Martin MPBB1 or MP2. Please refer to the
uploader manual for instructions on preparing the uploader for use.
N o r m a l u p l o a d w i t h M P B B 1
1.
Connect the MPBB1 to the fixture or serial link as if connecting a controller.
2.
Power up the fixtures and allow them to reset. Turn on the MPBB1.
3.
Use the arrow keys to select
to escape.
4.
Select DMX or Martin protocol. If the fixtures are set for auto protocol detection, either protocol
may be used. If not, the protocol must match the fixture
5.
Press [Enter]. The LEDs on the Exterior 600s are steady yellow to indicate an upload is in
progress. When the upload is complete, the MPBB1 displays
B o o t m o d e u p l o a d w i t h M P B B 1
If the data is corrupted during transmission, a check-sum error occurs that causes the fixture to switch to boot mode in
preparation for a second upload attempt. Execute a boot-mode upload as described in the uploader manual.
If an upload attempt is interrupted, the fixture must be powered off for at least 10 seconds before a second upload can
be attempted. When the fixture is powered on, a check-sum error occurs that causes it to switch to boot mode in prepa-
ration for the second upload attempt. Select boot mode upload on the uploader.
If the software in memory is corrupted, software can be installed using the "hard-boot" setting, which is enabled by
moving a jumper on the circuit board. This upload procedure is also used to install software if it includes an update of
the boot sector.
18
F IX T
from the MPBB1 menu. Press [Enter].
d M X
or
MA RT
) or all-fixtures (
S IN G
. Press [Enter]. Press [Enter] again to confirm.
TS EQ
F IX T
from the MPBB1 menu. Press [Enter] to continue or [Menu] to escape.
d M X
or
MA RT
SI N G
. Press [Enter]. Scroll to the fixture address. Press [Enter].
. Press [Enter].
CA L
OPEN
,
SPOS
(sensor), and
U PL d
Exterior 600
. Press [Enter].
mode. Press [Enter]. If you selected single-
A L L)
. Press [Enter].
), cyan (
d O F
C OF
RS T
), turn on and off the lamp (
APOS
(adjustment) positions, together (
from the MPBB1 menu. Press [Enter] to continue or [Menu]
), magenta (
), or yellow (
M O F
L O N
L o FF
,
A LL
) or individually.
PS ET
setting.
dO N E
and the fixtures reset.
).
Y OF
), and move