Adjustment Procedure
1. Set the stitch dial
2. Turn the hand-wheel
point.
3. Loosen the needle bar connecting stud clamping screw
4. Adjust the height of the needle bar
5. Fasten the needle bar connecting stud clamping screw
to [0] on the scale.
to bring the needle bar
to the specified dimension.
o Stitch skipping or thread breakage
to the lowest dead
4' At that time, align the bottom face
.
.
– 15 –
Results of Improper Adjustment
may result.
of the needle bar frame
the marker line engraved on the
needle bar (the upper one of the
two marker lines). This will en-
able you to adjust the height of
the needle bar almost to the
specified dimension.