Download Print this page

Abatronic AMB-12H Instruction Manual page 19

Through-wall air-to-air heat pump and air conditioner

Advertisement

screws.
■ Water Inlet Filter Cleaning
In order to ensure proper drainage the water inlet filter should be cleaned periodically. In
general, wash the water inlet filter once every 2 months. If air quality is bad leading to water inlet
filter blockage, the unit will produce abnormal noise during
running. In this situation, stop the unit immediately and wash
water inlet filter straight away. The procedure is as following,
Water inlet filter assembly drawing (Figure 21)
1. Water inlet filter bracket
2. Water inlet filter inner cover
3. Water inlet filter
4. Water inlet filter outer cover
Remove water inlet filter bracket by hand (fig
22 ). Depress the top clip and once it is loose at
the top, angle the top outwards and ease
sideways to allow the filter to be removed from
the aperture. Now feed out the water pipe to
allow good access.
Figure 22
Notes:
1. Do not use too much force to remove the water inlet filter bracket in order to prevent
damage to the bracket or filter.
2. Do not touch retainers/fixings of the back cover when taking out filter to avoid any
damage to filter.
3. Do not use too much force when pulling out the water pipe to avoid water pipe connector
breakage.
Hold the water inlet filter bracket with left hand, apply pressure to the 4 retainers of water inlet
filter outer cover to release with the right hand, then take out water inlet filter bracket inner cover,
and take out filter. (Figure 23)
- 18 -
FIG 21

Advertisement

loading

Related Products for Abatronic AMB-12H