Abatronic AMB-12H Instruction Manual page 11

Through-wall air-to-air heat pump and air conditioner

Advertisement

3. Put the spring retainer ring into wall and use 2 off ST5x16 screws to fix in place, please note
- put the 2 screws on the horizontal line (Figure 9)
4. Take the exhaust air duct cover and hook the retaining springs on to the spring retiner ring
installed as above. Angling the cover sideways as per fig 10, push it through the air duct and
allow it to fit back into the exhaust air duct with spring retaining pressure (Figure 10)
5. Assemble the other tube using the same method.
Note: Do not look into air ducts when stretching the cover retaining springs to avoid eyes or
face being struck in the unlikely event that a spring breaks or comes adrift. Wear the safety
goggles used for drilling operations. Extend springs gently and gradually to avoid damage.
3.3.3
INSTALL THE UNIT MOUNTING BRACKET
1. Knock the wall plugs into the drilled 13mm holes in the wall;
2. Put the mounting bracket in the correct position and fix it with at least 4 screws.( Figure 11)
3.3.4
INSTALL THE UNIT ONTO MOUNTING BRACKET.
Make sure the mounting bracket is well secured on to the wall and the necessary electrical
connections are made. Now hang the unit onto the mounting bracket.
Note: When mounting the heating and cooling model, please connect the atomization
device tube before finally hanging the unit onto hook. (Figure 15)
Fig11
- 10 -
Fig 9
Fig10