Download Print this page

schmersal RSS260 Operating Instructions Supplementary Sheet page 2

Combination of sensor and actuator

Advertisement

Operating Instructions Supplementary Sheet
Combination of sensor and actuator
Actuating directions
Actuation from front
12
Actuation from side
2
Lateral actuation only from the shown sensor side
Switching distances to IEC 60947-5-3:
Actuation
Typical switching distance:
Assured switching distance s
ao
- in the temperature range -10 °C ... +60 °C
- in the temperature range -25 °C ... +65 °C
Assured switch-off distance s
ar
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone:
+49 - (0)2 02 - 64 74 - 0
Telefax:
+49 - (0)2 02 - 64 74 - 1 00
E-Mail:
info@schmersal.com
Internet: http://www.schmersal.com
2
From front From side
12 mm
9 mm
:
10 mm
6 mm
8 mm
4 mm
:
18 mm
Axial misalignment
The axial misalignment (Y) is max. ± 18 mm. The height misalignment
(X) is max. ± 8 mm. Avoid area of side lobes if lateral activated.
Y
Actuating curves
The actuating curves represent the typical switching distance of the
safety sensor during the approach of the actuator subject to the
actuating direction
Transverse misalignment
S [mm]
12
10
5
0
-20
-15
-10
-5
0
5 10 15
Preferred actuation directions: from front or from side
In case of a lateral actuation, the switching distances are
reduced by approx. 3 mm.
Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery
Directive. As a result, Schmersal is entitled to autonomously conduct
the conformity assessment procedure for this combination of products
listed in Appendix IV of the MD without involving a notified body.
More technical information can be found in the Schmersal online
catalog on the Internet at www.schmersal.net.
EN
RSS260 / RST-U-2
Height misalignment
S [mm]
12
10
5
0
-24
-20
-15
-10
-5
0
5 10 15
20
Y [mm]
20 24
X [mm]

Advertisement

loading

This manual is also suitable for:

Rst-u-2