Transport And Storage; Installation And Connection - Brinkmann Suction Pumps Series Operating Instructions Manual

Table of Contents

Advertisement

3.7
Signs on the pump
It is imperative that signs affixed to the machine,
e.g.:
• arrow indicating the direction of rotation
• symbols indicating fluid connections
be observed and kept legible.
3.8
Unauthorized alterations and production
of spare parts
Any modification may be made to the machine only
after consultation with the manufacturer. Using
spare parts and accessories authorized by the
manufacturer is in the interest of safety. Use of
other parts may exempt the manufacturer from any
liability.

4 Transport and storage

Protect the pump against damage when transport-
ing.
Pumps must be drained prior to their storage.
Store pump in dry and protected areas and protect
it against penetration of foreign bodies.
Always store pump above the freezing point!

5 Installation and Connection

5.1
Mechanical installation
For the perfect function of the pump following
positions (see drawing 1) are permissible.
Pumps must be mounted securely. Piping, tank and
pumps must be mounted without any tension.
The suction and pressure connections are marked
with arrows of the pump body.
To obtain the full flow rate it is recommended to
choose for the pipework the nominal bore diameter
of the pumps cross section for connection. There-
fore pipe bends should be used, not pipe angles!
The pipework must be qualified for occurring hy-
draulic pressure.
Drawing 1
BE7700
Drawing 2
Pay attention of the max. tightening torque for
piping connection
Type
SB20...40
SB60
When installed the space around the pump
must be large enough to provide sufficient
cooling of the motor.
Do not prop up the pressure line via the joining
socket!
06/2019
Edition
ATTENTION
Pipe
Cast
connection
iron
G ¾
80 Nm
G ¾
80 Nm
Bronze
40 Nm
-