LG AR-DR12-05A Installation And Operation Manual page 138

Rooftop dedicated outdoor air system doas vx, base rooftop doas 800 to 5750 cfm, energy recovery wheel rooftop doas 900 to 9550 cfm
Hide thumbs Also See for AR-DR12-05A:
Table of Contents

Advertisement

CONTROLLER
Network Settings Data Tables
Table 28: Network Settings Data Table, continued.
Control Variable
Unit Configuration, continued.
Controls Lite Mode
Heating Enabled
Case Heat Installed
Compressor Config - Stage
Compressor Config- Ramp
Compressor Config-Circuit
Compressor Config-
Modulates
Change Lead Lag Mode
Change Lead Lag Day
Ramp 1 Lead Order Stage
(1-8)
Ramp 1 Lag Order Stage
(1-8)
OAD Space Static Enabled
Reheat Plus Enabled
Heat Pump Defrost
Enabled
Max. Elec. Heat
CMN Breakout BMS Comm
CMN Breakout Dmp Ctrl
CMN Breakout Sup Fan
CMN Breakout CO
Ctrl
2
CMN Breakout Exh Fan
CMN Breakout Rem Dmp
CMN Breakout PreHeat
CMN Breakout Air Flow
CMN Breakout Heating
CMN Breakout Cooling
CMN Breakout Enrg Rec
CMN Breakout Economizer
CMN Breakout AMD Type
CMN Breakout Cond Fan
CMN Breakout Cond HPC
CMN Breakout Heat Pump
Set-point availability varies based on unit configuration.
138
Default
Set-point
Enabled (X)
Disabled (□)
Not Installed (□)
Not Installed (□)
Lead
Monday
1
1
Disabled (□)
Disabled (□)
Disabled (□)
Disabled (□)
Enabled (X)
Disabled (□)
100%
Stand Alone, Lontalk, BACnet IP, BACnet MSTP, MODBUS RTU, MODBUS IP
Constant Volume, VAV Duct Static, Hardwired Input, BMS, CV Damper Static, Space Static,
None, Supply Tracking, Space Pressure, Hardwired, BMS Control, CFM Control
Disabled, BMS Control, CFM Control
None, Supply Inlet Cone, IAQ Damper, Supply Inlet & IAQ Damper, Exhaust Inlet Cone, Supply
& Exhaust Inlet Cones, Exhaust Inlet & IAQ Damper, SF/EF Inlets & IAQ Damper
None, Gas 1 or 2 burner, Gas and Electric, Electric Only, 12:1 Gas, Hot Water, 6:1 Gas, 10:1-2
None, 1 Compressor, 2 Compressors, 4 Compressors, 1 Mod Comp, 2 Comps w/Mod, 4
None, Heat Wheel w/VFD, Heat Wheel On/Off, Sensible Plate, Enthalpic Plate, Enthalpic Plate
None, 1 Fan, 2 Fans, 3 Fans, 4 Fans, 6 Fans, 8 Fans
None, 1.0 A Only, 1.0 B Only, 1.0 A and B, 2.0 A Only, 2.0 B Only, 2.0 A and B, 2.0 A/B Split
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Min.
Set-point
Read Only
Read Only
Read Only
Read Only
Lead, Lag, w/Dehumid, Weekly
Not Installed, Standard c.pCO, c.pCOe
1
No. Comps on Ramp
1
No. Comps on Ramp
0%
100% Outside Air, Recirculating
Single Zone VAV, CFM Control
Disabled, Enabled
None, Installed
Furnace Gas
Comps w/Mod, Chilled Water
with Bypass
None, Installed
Standard, Thermal Dispersion
None, ASHP, WSHP
Max.
Demand
Enabled (X)
Installed (X)
Enabled (X)
Enabled (X)
Enabled (X)
100%
Notes
Up to 8 compressors
Up to 8 compressors
Up to 8 compressors
Up to 8 compressors
Shows when Weekly
is selected
Has only 1 Cooling
Ramp with up to 4
stages
Has only 1 Cooling
Ramp with up to 4
stages
Only shows when
Reheat Plus is
Installed from
CMN
Shows when unit is
configured as
an ASHP
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN
CMN