Instruction Book IB182312EN
50/75/150 VCP-W
Selectable Ground and Test Device
Supersedes October 2015
Effective
June 2016
150 VCP-W-SGT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VCP-W Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton VCP-W Series

  • Page 1 Supersedes October 2015 Instruction Book IB182312EN Effective June 2016 50/75/150 VCP-W Selectable Ground and Test Device 150 VCP-W-SGT...
  • Page 2 SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein.
  • Page 3: Table Of Contents

    4.1 INSULATING BARRIERS 4.2 BUSHINGS AND DISCONNECTING CONTACT ASSEMBLIES 11 SECTION 7: REPLACEMENT OF COMPONENTS 4.3 GROUNDING CONTACTS 7.1 GENERAL 4.4 BREAKER-CELL CODING PLATES 7.1.1 ORDERING INSTRUCTIONS 4.5 CELL POSITION DESCRIPTION 4.6 DEVICE AMPERAGE CONVERSION PROCEDURE Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 4: Section 1: Introduction

    VCP-W Selectable Ground and Test Devices. This selectable ground and test device is designed to be used in existing Westinghouse, Cutler-Hammer, or Eaton Type VCP-W metal-clad switchgear. Type VCP-W selectable ground and test devices are designed for insertion into the breaker compartment to gain access to the primary stationary contacts.
  • Page 5 150 VCP-W 500 Dual 1200 / 2000 28.50 26.76 10.00 27.81 12.00 14.13 20.88 24.63 2.25 27.80 29.55 150 VCP-W 500 Dual 3000 28.50 26.76 10.00 27.96 12.00 14.13 20.88 24.63 2.25 27.80 29.55 Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 6: Section 2: Safe Practices

    Remember that line connection may be on lower terminals when installed in upper compartment of 2-high switchgear. Store the device in a clean, dry area free from dust, dirt, • moisture, etc. Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 7: Section 3: Receiving, Handling, And Storage

    File claims immediately with the carrier if damage or loss is detected and notify the nearest Eaton’s Electrical Services & System office. Figure 3.2. Lifting 150 VCP-W-SG&T...
  • Page 8: Storage

    Indoor storage should be in a building with sufficient heat and circulations to prevent condensation. If the building is not heated, the same general rule for heat as for outdoor storage should be applied. Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 9 Lock-out / Tag-out Ring Kirk Key Interlock* Lift / Pull Handle Friction Hinge Spring Loaded Kirk Lock Bolt* Ground Contact Selector Blade Latch Ring Code Plate otee: * May be deleted at option of end user. Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 10 50/75/150 VCP-W Selectable Ground and Test Device Figure 3.3.b. Rear External View of 150 VCP-W SG&T Device Back External View (150 VCP-W SG&T Shown) Lifting Point Primary Disconnects (1200A / 2000A Shown) Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 11: Section 4: Description And Operation

    BEEN INSTALLED FOR THE CORRECT APPLICATION. 4.5 CELL POSITION DESCRIPTION Position A: This is the withdrawn position. In the withdrawn position, the selectable ground and test device is out of the cell. The racking Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 12 Figure 4.3. Primary Disconnect Hardware Removal (3000A) Figure 4.6. Primary Disconnect Installation (1200A/2000A) Figure 4.4. Primary Disconnect Removal (3000A) Figure 4.7. Primary Disconnect Hardware Installation (1200A/2000A)) Figure 4.5. Primary Disconnect Shim Removal (3000A) Figure 4.8. Primary Disconnect Installed (1200A/2000A) Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 13: Device Amperage Conversion Procedure

    The left hand code plate is used for the continuous current rating, the right hand code plate corresponds to the short circuit capabilities of the device. Eaton offers many code plate combinations for accepting or rejecting devices...
  • Page 14: Selectable Ground And Test Device

    If any discrepancies exist, the terminals to be grounded. These removable barriers should notify Eaton’s Electrical Services & Systems for resolution prior to be safely stored for re-installation before returning the SG&T proceeding.
  • Page 15 Figure 5.5. Selector Blade Disengaged (Shown in Upper Position) Figure 5.2. Access Door Friction Hinge Figure 5.6. Utilizing Hot Stick To Engage Selector Blade Figure 5.3. Selector Blade Figure 5.7. Selector Blade Engaged (Shown in Upper Position) Figure 5.4. Removing Insulating Barrier Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 16: Insertion Procedure

    (Figure 5.9). Once the extension rails are properly in place, the SG&T can be carefully loaded on the extension rails using an overhead lifter and lifting yoke. Remove the lifting yoke when the SG&T is securely seated on the extension rails. Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 17 Pull up on the Lift/Pull Handle as shown in Figure 5.12 then pull the device out onto the extension rails. Use a lifting yoke and overhead lifter to remove the SG&T from the extension rails. Instruction Book IB182312EN June 2016 www.eaton.com...
  • Page 18: Section 6: Inspection And Maintenance

    Visually inspect all insulating barriers. Ensure that there is not dirt visible on the surface of any of the barriers. If dirt is found, clean with a lint-free cloth. If a solvent is required to cut dirt, used Stoddard’s Solvent (Eaton part number 55812CA) or commercial equivalent. Hardware Visually inspect all hardware.
  • Page 19: Section 7: Replacement Of Components

    2. Describe the item, give the style number, and specify the quantity required. 3. Specify the method of shipping desired. 4. Send all orders or correspondence to the nearest Eaton’s Electrical Services & Systems sales office. 5. Include negotiation number with order when applicable.
  • Page 20 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2016 Eaton All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No. IB182312EN All trademarks are property June 2016 of their respective owners.