Advertisement

Instruction Leaflet IL01906008E
Instructions for Testing Magnum DS
Digitrips with the MTK2000 Test Kit
Contents
Description
1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2: MTK2000 / Breaker Information . . . . . . . . . . . . 2
3: MTK2000 Setup . . . . . . . . . . . . . . . . . . . . . . . . 5
5: Testing the 1150 Digitrip Models . . . . . . . . . . . . 8
6: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . 11
7: Customer Updates . . . . . . . . . . . . . . . . . . . . . 12
8: Additional Publications . . . . . . . . . . . . . . . . . . . 12
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTK2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton MTK2000

  • Page 1: Table Of Contents

    1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2: MTK2000 / Breaker Information . . . . . . . . . . . . 2 3: MTK2000 Setup .
  • Page 2: Effective March 2011

    Warnings anD cautions relating to the safety of personnel state circuitry functions . Current is applied through the selected phase and returns to MTK2000 via the neutral element . It is only anD equipment, as Well as all general anD local health anD necessary to use one circuit function (e .g ., Long Delay) to verify that...
  • Page 3 2.3 MTK2000 Breaker Cables The MTK2000 MDS Breaker Cable is used to connect the MTK2000 to the breaker’s trip unit . Before the MDS 14 pin MTK2000 plug is inserted into the Digitrip verify the Long Time Memory (LTM) jumper is in the inactive position, or it is removed . If it is in the active posi- tion, it must be removed or returned to the inactive position before the adapter connector can be inserted .
  • Page 4 . This jumper is shipped from the factory in the “active” position . (Reference Section 2 .3, MTK2000 Breaker Cables) If a trip function LED on the Trip Unit is lit prior to a test, press the Trip Reset pushbutton on the Trip Unit .
  • Page 5: 3: Mtk2000 Setup

    Models 3.1 General Information 4.1 Legend for MTK2000 testing with 520 Digitrips Place the MTK2000 on a stable surface prior to testing . The handle can be rotated for ease of viewing and operation by pressing the g= entered ground value setting buttons on the sides of the handle and rotating the handle to the GF= Ground Setting desired angle (see Flowchart at back of document) .
  • Page 6 Up and Down Arrow . Press Test Select button when TERMINATED ->PASSED” or “TEST TERMINATED ->FAILED” will complete . appear on the MTK2000 display . The current level is the Long Delay 4.5 ZSI Shorting Plug Pickup Value, this is the value where the trip unit will Start timing for Long Delay (overload protection) .
  • Page 7 4.13.1 MDS 520 Digitrip Models After the “SHORT DELAY TEST” current is found press Test Select until “SHORT DELAY (at 1 .5xs)” comes up on the MTK2000 display . If red light is blinking press “Reset” on Digitrip . If Test Select is hit more than once, the MTK will skip the next test ote: Set value on the Long Delay dial to maximum .
  • Page 8: 5: Testing The 1150 Digitrip Models

    If any of the red LEDs are blinking on Digitrip press Reset . SDT= SHORT TIME 4.16.2 MTK2000 T= is the entered time value the MTK2000 started a time test at After the “MAINTENANCE MODE” current is found press Test = entered time value for the “GROUND TIME”...
  • Page 9 5.3 Setting the Rating Plug 5.7.2 MTK2000 Press Start to set the rating plug value on the MTK2000 by using “LONG DELAY TEST” should be shown on the screen if not press the scroll up and down button . Press Test Select button when com- Test Select until “LONG DELAY TEST”...
  • Page 10 FAILED” will appear on the MTK2000 display . 5.10 Short Delay Time Settings ote: If test is failing please reference Section 2 .3 MTK2000 Breaker Cables . 5.10.1 MDS 1150 Digitrip Models 5.13 Instantaneous Settings (If Applicable) If any of the red LEDs are blinking press “Reset” on Digitrip .
  • Page 11: 6: Troubleshooting

    • Trip when testing Short Delay Pickup). Verify that the trip unit is set correctly as indicated on the MTK2000 Once selection has been made, press “Save” under the “Edit Value” prior to Starting the test and that the trip unit is reset prior to Menus buttons .
  • Page 12: 7: Customer Updates

    MTK2000 Test Kit . These updates Maintenance of Magnum DS, DSX and DSL Low Voltage Power Circuit Breakers are to be performed by the MTK2000 Test Kit user using the IB 2C12063H02 Instructions for Installation, Operation and included data communication cable .
  • Page 13: Appendix

    Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 Appendix EaTon CorporaTIon www.eaton.com...
  • Page 14 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 15 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 16 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 17 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 18 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 19 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 20 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 21 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 22 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 23 Instruction Leaflet IL01906008E Instructions for Testing Magnum DS Digitrips with the MTK2000 Test Kit Effective March 2011 EaTon CorporaTIon www.eaton.com...
  • Page 24 OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS, AND DESCRIPTIONS CONTAINED HEREIN. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of...