Error Check; On Temp Sensor; On Film Sensor; Film In Error - JPI JP-33 Service Manual

Automatic film processor
Table of Contents

Advertisement

Technical Support

1. ON Temp Sensor.

Reason: Open & Short a Temperature Sensor (Pt-100)
Situation
1) Beep: beeping continuous.
2) Display: "DEV xxxF℃ XX℃"on LCD.
Recovering
1) Tentative: MODE switches ON
2) Regular: Change a temperature sensor
2. ON film
Sensor.
Reason: Hold a magnetic film sensor ON-Mode.
Situation
1) Beep: sound an error beeping.
2) Display: "error on Film Sensor" at LCD.
Recovering: Adjust a sensor arm and change sensor switch.

3. Film in error

Reason: Film overlap at feed-in.
Situation
1) Beeping: sound an error beeping one time.
2) Display: "Film-in error"
Recovering: can automatically recovering after overlap film-in finishing.
4. System error
Reason: Not ready yet at initial Power-ON or have something system trouble
Situation
1) Beep: sound an error beeping
2) Display: Power Up again when motor off
Recovering: Retry switching OFF and wait for 120seconds.
1. Status: Flash On
2. Status: Lighting On ....... ready
3. Status: Lighting Off .......during the film feeding
PROCESS TIME
Mode – Developing ------ Ventilate
90 ---- 118 sec ------- 30sec
120 ---- 154 sec ------- 30sec
180 ---- 226 sec ------- 30sec
210 ---- 262 sec ------- 30sec
JP-33 SERVICE MANUAL

ERROR CHECK

automatically can setting to 32'C default.
READY Indicator Operation
....... not ready by setting temperature
- -
JOG CYCLE TIME at stand-by
1. FAN: 60sec work at 15minute term
2. Motor: 30sec work at 30minute term
3. RPL Pump: 15sec work at 30minute term
52
- Electrical Schematic