1.7 Problem
Chemicals are being supplied without stopping.

Check the operation of the Film Detection Sensor.

Check feed sensor, refer to trouble shooting section 1.2.
1.8 Problem
Film is not drying

Check if the Dryer air is warm or cold.

If the dryer air is cold, then the dryer heater is malfunctioning. Contact Technical
support ASAP.
If the dryer air is warm, then the fixer may be exhausted or the washer is contaminated.
Replace the fixer and/or cleaning water.
Check if dryer vents in the Dry Rack are aligned properly.
1.9 Problem

During processing you hear squeaking

Check for air bubbles in re-circulation pump or if the pump is empty.

Check if there is sufficient chemical in the tank.
Drain the air bubbles.
: How to drain air bubbles is described in trouble shooting section 1.5.